ACHR News
search
Ask ACHR NEWS AI
cart
facebook twitter instagram linkedin youtube
  • Sign In
  • Subscribe
  • Sign Out
  • My Account
ACHR News
  • NEWS
    • Breaking News
    • New HVAC Products
    • Featured Products
    • Manufacturer Reports
    • HVAC Data
    • Legislation
    • ACHR NEWS Centennial
  • RESIDENTIAL
    • Air Conditioners
    • Furnaces
    • Residential Heat Pumps
    • Ductless
    • Residential IAQ
    • Testing, Monitoring, Tools
    • Components & Accessories
  • COMMERCIAL
    • Air Handlers
    • Rooftop Units
    • Chillers and Cooling Towers
    • Commercial Heat Pumps
    • Boilers and Hydronics
    • VRF/Ductless
    • Commercial IAQ
  • REFRIGERATION
    • Refrigerants
    • Refrigerant Regulations
    • Leak Management
  • CONTRACTOR PRO
    • Geothermal
    • Homeowner Study
    • VRF and VRV Ductless
    • Unitary Trends
  • EDUCATION
    • Training and Education
    • Business Management
    • Service and Maintenance
    • Continuing Education
    • Market Research >
      • HVAC Brand Awareness Report
      • VRV, VRF, VRVZ Report
      • Unitary Trends Report
      • Water Heat Professionals Report
    • Webinars
    • Sponsor Insights
    • eProducts Info
    • White Papers
  • EVENTS
    • HVAC Contractor Forum
    • Industry Events and Webinars
  • MEDIA
    • Videos
    • AHR Expo 2025 Videos
    • Podcasts >
      • ACHR News Podcast
      • HARDI Podcasts
      • AHR Expo Podcasts
      • ACCA Podcasts
    • Interactive Spotlights
    • Quizzes
    • eBooks
    • HVAC Talkback
  • HVAC GROUP
    • ACHR NEWS >
      • Current Issue
      • Digital Edition
      • Subscribe
    • Distribution Trends
    • SNIPS NEWS >
      • Join SNIPS NEWS
    • Engineered Systems News >
      • Join ES News
    • HVACR Directory
    • Contests
    • Newsletters
    • Contact
    • Advertise
    • My Account
NewsHVAC Residential MarketIndoor Air Quality

Fresh Air, Energy Savings, and Comfort: The Case for Air Handler Accessories

Optional residential equipment can be attached to, or near, air handlers in ducted systems

By Matt Jachman
AprilAire-Model-AUV24V-UVC.jpg
Courtesy of AprilAire

CONTAMINANTS KILLER: The installation of an AprilAire Model AUV24V UVC system, which is used to kill or inactivate contaminants that can accumulate on the coil in a ducted system.

August 27, 2025
?
Image in modal.

While a furnace provides heat when the weather is cold and an a/c unit removes it when it’s hot, neither are effective in a ducted HVAC system without being attached to an air handler. 

But optional equipment for ducted systems that can bring in fresh air, filter the air, kill germs, regulate humidity levels, or even save energy can also be attached to air handlers, or near them. These include UV-C light units, energy recovery ventilators, and whole-home humidifiers and dehumidifiers. 

The ACHR NEWS asked several manufacturers about some of these products and how contractors might want to start conversations with their residential customers about adding them. Here’s what they had to say. 

 

Add Fresh Air, Save Energy 

When a customer complains about stale indoor air, mentions allergies, or has a newer, tightly sealed home built to modern energy codes, it might be time to suggest an energy recovery ventilator (ERV). 

ERVs introduce fresh air into ducted systems and save energy by preconditioning that air with the help of exhaust air, which has already been cooled or heated, and a heat exchanger. ERVs can also wick moisture from incoming air when the weather is humid, and harness moisture from outgoing air when it’s dry or cold outside, to help maintain comfortable indoor humidity levels. 

“This translates into lower HVAC loads, especially in extreme climates, and can contribute to noticeable reductions in heating and cooling costs over time,” said Chrystal Jolliffe, an IAQ product manager at Carrier. 

Carrier’s Performance ERV line has models with airflow capacities of up to 210 cfm; the airflow can be adjusted by the users. 

Looking for quick answers on air conditioning, heating and refrigeration topics? Try Ask ACHR NEWS, our new smart AI search tool. Ask ACHR NEWS →

“These units typically integrate with smart thermostats or analog controls that allow homeowners to modulate airflow based on comfort preferences or seasonal needs,” Jolliffe said. “Some models also feature auto-balancing for simplified setup and operation.” 

While residential ERVs are “a good option in any climate where humidity control is a concern,” Jolliffe said, they’re most popular in humid regions, like the Southeastern U.S., and tightly sealed homes, in more northerly regions, that need fresh air without sacrificing heating. 

“Airtight homes have high potential to build up and hold contaminants inside of the house much faster than ‘loose’ homes, impacting the IAQ,” said Szabi Fekete, sales and quoting engineer at Zehnder America Inc. “The majority of the U.S. has humidity issues during the year, so having a unit that handles sensible and latent transfer will benefit those homes. ERVs introduce less humidity to the home during the humid season and lose less to outside during the dry season.” 

Zehnder offers three models of its ComfoAir Q ERVs, named for their airflow capacity: 350, 450, and 600 cubic meters per hour. ComfoAir Q units can recover up to 94% of outgoing sensible heat, Fekete said, and up to 72% of outgoing latent heat. 

Zehnder’s ComfoAir Q ERVs

ENERGY SAVINGS: Zehnder’s ComfoAir Q ERVs, a pair of which is shown here, can recover up to 94% of outgoing sensible heat and up to 72% of outgoing latent heat, saving energy in a ducted system. (Courtesy of Zehnder America Inc.)

An important consideration when gauging the net energy savings of an ERV, he added, is how much power (Watts per cfm) is needed to move fresh air into the system.  

“Zehnder is using one of the most efficient ECM (electronically commutated motor) fans available,” he said. 

 

Clearing The Air 

Homeowners who have particular concerns about IAQ and airborne contaminants might want to hear about air-purification products, such as the kind made by AprilAire. 

AprilAire’s Model AUV24V UV-C system uses short-wavelength ultraviolet light (UV-C) to kill up to 99.9% of coil mold, plus kill or render inactive other contaminants, according to Brooke Nontelle, an AprilAire product manager. 

“Odors caused by mold or bacterial buildup on the coils can smell musty like ‘dirty socks.’ Homeowners noticing these odors should consider installing a UV-C sanitation system,” said Chris Howells, a senior training and development manager at AprilAire. “Contractors noticing visual buildup of mold or bacteria on the coils during maintenance, or smelling these odors upon entering the house or mechanicals room, can present the AprilAire UV-C Sanitation System as a solution.” 

The Model AUV24V UVC is attached to an air handler, near the coil, and should cover as much of the coil surface area as possible with UV-C light. The lamp should be a minimum of 8 inches from the top of the coil for a front-mount installation, and a minimum of 3 inches from the top of the coil for a side-mount installation, Howells said. 

AprilAire Model AUV24V UVC system

LET THERE BE LIGHT: An AprilAire Model AUV24V UVC system. When placed correctly near the coil in a ducted HVAC system, the Model AUV24V uses short-wavelength ultraviolet light (UVC) to kill up to 99.9% of coil mold and kill or inactivate other contaminants. (Courtesy of AprilAire)

The AUV24V UVC has the added benefit of helping maintain an HVAC system’s energy efficiency by guarding against the buildup of biofilm on the coil. Biofilm buildup can reduce the coil’s heat-transfer efficiency, Nontelle said, in addition to containing contaminants that can be sent into the air. 

AprilAire also makes the 1000 Series media air cleaners, which offer MERV 11 filtration that can be upgraded to MERV 13.  

“We have found successful HVAC contractors take a consultative approach around indoor air quality by first listening to homeowner needs and concerns with a focus on health and comfort,” said Howells. “HVAC professionals are key in educating homeowners on the benefits of whole-home air purification.” 

The 1000 Series air cleaners trap particles before they accumulate on the coil, which helps improve IAQ and keeps the coil clean and running efficiently, Howells added. 

A 1000 Series air cleaner features a 4-inch pleated filter, designed to last up to a year, that has up to nine times the surface area of a 1-inch filter and thus has more particle-trapping ability. The 1000 Series models also present low static air pressure, Nontelle said. 

An AprilAire 1000 Series should not be placed downstream of a UV-C light, as the light can degrade the filter media, the company said. 

 

Getting Humidity Right 

In dry climates, or in wintertime in much of the country, homeowners might be interested in humidification products. Carrier’s Performance large, fan-powered model can put up to 18 gallons of water into the air daily and is designed to humidify homes of up to 4,200 square feet. 

Carrier’s Performance model

HUMIDITY CONTROL: Carrier’s Performance model large, fan-powered humidifier can put up to 18 gallons of water into the air daily and is designed for homes of up to 4,200 square feet. (Courtesy of Carrier)

“The system integrates with the home’s HVAC controls to regulate moisture levels, and when paired with a compatible thermostat or humidistat, users can fine-tune humidity settings for optimal performance,” said Carrier’s Jolliffe. 

Humidifiers are most commonly found in colder areas of the U.S., Jolliffe said, where winter air is dry. They maintain proper indoor humidity levels, which helps protect occupants from dry skin, dried-out nasal passages, and static shocks. They also protect wood flooring and furniture from cracking due to dry air. 

Humidifiers also help save energy. 

“By making the air feel warmer, homeowners can lower their thermostat settings and reduce heating costs,” Jolliffe said. 

In homes where too much moisture is a problem, a whole-home dehumidifier, such as the Santa Fe Ultra V155, might be the answer. 

The Ultra V155, just introduced in June, features an 8-inch ventilation duct (up from 6 inches on previous humidifier models), MERV 13 filtration, dual-coated coils for moisture removal, and a secondary drain port, and is Energy Star-rated, said Nikki Krueger, director of marketing and business development at Santa Fe Dehumidifiers. The model can remove up to 155 pints (nearly 26 gallons) of water from the air daily and is designed for homes of up to 3,500 square feet. 

The larger ducts, Krueger said, help meet ASHRAE Standard 62.2 (ASHRAE’s recommendation for ventilation and IAQ in low-rise residential buildings), and also provide more outdoor air to align with the Ultra V155’s dehumidification capacity. 

Jonathan Esquivel, owner of Austin Star Services in Austin, Texas

WHOLE-HOME DEUMIDIFICATION: Jonathan Esquivel, owner of Austin Star Services in Austin, Texas, poses with an installed Ultra V155 from Santa Fe Dehumidifiers, which is designed for homes of up to 3,500 square feet. (Courtesy of Santa Fe Dehumidifiers)

The Ultra V155 ventilation feature is optional, and the fan can be controlled by a thermostat, Santa Fe’s DEH3000 controller, or its SmartAire power damper, which includes a fan timer. 

“We are supplying air to try to help put a slight positive pressure on the home to minimize infiltration of hot, humid air from the outside,” Krueger said of the ventilation feature. “This is recommended in the building science community and can help prevent condensation in walls when achieved.” 

Santa Fe typically recommends whole-house dehumidifiers in “green grass climates,” Krueger said. 

“These are areas where there is an inch of rain or more a week during the humid seasons, spring, summer, and fall,” she said. “As homes are being constructed tighter and tighter, the more need there is for whole-house dedicated dehumidification. Tighter houses mean less a/c runtime — which is ultimately the goal of a tight home.” 

In addition, Krueger added, modern a/c systems prioritize temperature reduction over moisture removal in order to meet energy-efficiency goals. “This shift often leaves latent loads unaddressed, resulting in humid indoor conditions,” she said. 

KEYWORDS: Air movement air purification airflow management residential HVAC system

Share This Story

Looking for a reprint of this article?
From high-res PDFs to custom plaques, order your copy today!

 

Matt jachman

Matt Jachman is an editor at the ACHR NEWS. He has 30-plus years of experience in community journalism and a bachelor’s degree in English from Wayne State University in Detroit.

Recommended Content

JOIN TODAY
To unlock your recommendations.

Already have an account? Sign In

  • HVAC-enrollment

    The Trades Are Back: HVACR Programs See Nearly 30% Enrollment Spike

    A new wave of future technicians is entering the pipeline.  
    News
    By: Matt Jachman
  • 2025 Top 40 Under 40

    2025 Top 40 Under 40 HVACR Professionals List

    The 11th annual Top 40 Under 40 list highlights those...
    HVAC Residential Market
    By: Hannah Belloli-Oster
  • LG Ductless Mini-Split Systems

    The 9 Types of Heat Pumps

    As the U.S. moves toward electrification, heat pumps are...
    HVAC Residential Market
    By: Joanna R. Turpin
Subscription Center
  • Create an Account
  • Start a Subscription
  • Manage My Account
  • Sign Up for Newsletters
  • Visit Customer Service
  • Update Preferences

More Videos

Sponsored Content

Sponsored Content is a special paid section where industry companies provide high quality, objective, non-commercial content around topics of interest to The News audience. All Sponsored Content is supplied by the advertising company and any opinions expressed in this article are those of the author and not necessarily reflect the views of The News or its parent company, BNP Media. Interested in participating in our Sponsored Content section? Contact your local rep!

close
  • Piggy Bank
    Sponsored byWatercress Financial

    Energy Prices, Inflation, and HVAC: What Today’s Homeowners Care About

  • Refrigerated Food
    Sponsored bySolstice Advanced Materials

    R-455A Refrigeration: A Cold Storage Solution for the Future

  • Airex Rooftop Units
    Sponsored byAirex Manufacturing Inc

    Consolidating Roof Penetrations: A Growing Trend in Multifamily HVAC Design

Popular Stories

HVAC-Price-Increase-graphic

HVAC Price Increase List: June 2026

Trump-Section-232.jpg

Trump Reduces Section 232 Tariffs on HVAC Equipment to 15%

Refrigerants-and-gauge.jpg

HVAC Industry Warns of Counterfeit Refrigerants Entering U.S. Supply Chain

Heat-pump-cutaway.jpg

PFAS Rules and A2L Building Codes Continue to Evolve

Midea-training.jpg

HVAC Workforce Crisis Expands Beyond Technicians to Instructor Shortages

View The ACHR NEWS
Centennial Anniversary Timeline

The ACHR News Timeline Chart
Submit a Letter
Submit a letter to our editors.

Events

November 6, 2025

Next-Gen Data Center Cooling: HVAC Innovation and Real-World Solutions

On Demand As AI workloads and high-density computing push traditional cooling methods to their limits, the data center industry is accelerating the adoption of next-generation HVAC technologies.

June 17, 2026

Decarbonization Without Disruption

This webinar will explore practical HVAC decarbonization strategies that minimize disruption while maximizing long-term performance and ROI.

View All Submit An Event

Poll

Summer Staff

Are you fully staffed for the summer season?
View Results Poll Archive

Products

BNI Mechanical/Electrical Square Foot Costbook, 2026 Edition

BNI Mechanical/Electrical Square Foot Costbook, 2026 Edition

See More Products
Decarbonization Without Disruption - Free Webinar - 6/17/2026

Related Articles

  • Home Comfort Zones Inc.: Energy-Savings, Comfort System

    See More
  • adsorption cooling systems

    PNNL Research Supports the Case for More Efficient Air Conditioning

    See More
  • Home Comfort Zones Inc.: Energy-Savings, Comfort System

    See More

Related Products

See More Products
  • air came to a stop.jpg

    The Air Came to a Stop

  • HVACR-Troubleshooting-Fundamentals-Cover-Image-One-Sheet.jpg

    HVACR Troubleshooting Fundamentals - Refrigeration & Air Flow Systems Training Package for Instructors & Service Managers

  • Uncomplicating The Heat Pump: Refrigeration & Air Flow Systems DVD

See More Products

Events

View AllSubmit An Event
  • July 31, 2025

    Air Handler Innovation for a Shifting Housing Market

    On Demand Explore how air handler applications are adapting to meet the needs of traditional single-family homes as well as the growing multi-family and manufactured housing market.
View AllSubmit An Event
×

Sign Up. Stay Informed.

The #1 trusted source for the HVACR industry since 1926

SUBSCRIBE
  • RESOURCES
    • Advertise
    • Contact Us
    • Advisory Board
    • Classifieds
    • Submit a Letter
    • Directories
    • Store
  • ACCOUNT CENTER
    • Create an Account
    • Start a Subscription
    • Manage My Account
    • Sign Up for Newsletters
    • Visit Customer Service
    • Update Preferences
  • SERVICES
    • Marketing Services
    • Reprints
    • Market Research
    • List Rental
    • Survey/Respondent Access
  • STAY CONNECTED
    • LinkedIn
    • Facebook
    • Instagram
    • YouTube
    • X (Twitter)
  • PRIVACY
    • PRIVACY POLICY
    • TERMS & CONDITIONS
    • DO NOT SELL MY PERSONAL INFORMATION
    • PRIVACY REQUEST
    • ACCESSIBILITY

Copyright ©2026. All Rights Reserved BNP Media, Inc. and BNP Media II, LLC.

Design, CMS, Hosting & Web Development :: ePublishing