ACHR News
search
Ask ACHR NEWS AI
cart
facebook twitter instagram linkedin youtube
  • Sign In
  • Subscribe
  • Sign Out
  • My Account
ACHR News
  • NEWS
    • Breaking News
    • New HVAC Products
    • Featured Products
    • Manufacturer Reports
    • HVAC Data
    • Legislation
    • ACHR NEWS Centennial
  • RESIDENTIAL
    • Air Conditioners
    • Furnaces
    • Residential Heat Pumps
    • Ductless
    • Residential IAQ
    • Testing, Monitoring, Tools
    • Components & Accessories
  • COMMERCIAL
    • Air Handlers
    • Rooftop Units
    • Chillers and Cooling Towers
    • Commercial Heat Pumps
    • Boilers and Hydronics
    • VRF/Ductless
    • Commercial IAQ
  • REFRIGERATION
    • Refrigerants
    • Refrigerant Regulations
    • Leak Management
  • CONTRACTOR PRO
    • Geothermal
    • Homeowner Study
    • VRF and VRV Ductless
    • Unitary Trends
  • EDUCATION
    • Training and Education
    • Business Management
    • Service and Maintenance
    • Continuing Education
    • Market Research >
      • HVAC Brand Awareness Report
      • VRV, VRF, VRVZ Report
      • Unitary Trends Report
      • Water Heat Professionals Report
    • Webinars
    • Sponsor Insights
    • eProducts Info
    • White Papers
  • EVENTS
    • HVAC Contractor Forum
    • Industry Events and Webinars
  • MEDIA
    • Videos
    • AHR Expo 2025 Videos
    • Podcasts >
      • ACHR News Podcast
      • HARDI Podcasts
      • AHR Expo Podcasts
      • ACCA Podcasts
    • Interactive Spotlights
    • Quizzes
    • eBooks
    • HVAC Talkback
  • HVAC GROUP
    • ACHR NEWS >
      • Current Issue
      • Digital Edition
      • Subscribe
    • Distribution Trends
    • SNIPS NEWS >
      • Join SNIPS NEWS
    • Engineered Systems News >
      • Join ES News
    • HVACR Directory
    • Contests
    • Newsletters
    • Contact
    • Advertise
    • My Account
HVAC ContractingNewsService and MaintenanceRefrigerationTesting | Monitoring | ToolsGuest ColumnLeak Detectors

Choosing, Selecting, and Utilizing a Refrigerant Leak Detector

By Paul Flora
Refrigerant Containers
LEAK DETECTION: An accurate leak detection method and good practices must be utilized to find a leak in a system and correctly address it. (Staff photo)
April 27, 2023

Listed below are the most common refrigerants you may encounter as a service technician. I’ve arranged them in groups.

  • Chlorofluorocarbon (CFC) — R-12 and R-502 (Phased out)
  • Hydrochlorofluorocarbon (HCFC) — R-22, R-401A, R-401B, R-402A, R-402B, R-408A, and R-409A (in phaseout)
  • Hydrofluorocarbon (HFC) — R-134a, R-404A, R-407C, R-410A, R-438A, and R-507

READ MORE ABOUT

• Leak Detectors

• Leak Prevention

• Refrigeration

Current U.S. Environmental Protection Agency (EPA) regulations recommend and/or require leak detection and repair when it’s been determined that a system is losing refrigerant. The EPA will soon release new rules governing the handling and leak detection of R-410A and other leak rate criteria changes that will all make good leak detection practices even more important. An accurate leak detection method and good practices must be utilized to find a leak in a system and correctly address it. Listed below are the accepted methods of leak detection. Only those methods that work with HFCs are listed.

  • Soap Bubbles — This is a visible method that works with all refrigerants and is very accurate for pinpointing a leak;
  • Fluorescent Dye — This is a visible method that works with all refrigerants. It must be added to the refrigerant and a special UV light is required; and
  • Electronic Leak Detectors — Currently, this is the most popular method in use. It works with all refrigerants and is very accurate or very inaccurate, depending on the sensor condition. It must be checked regularly against a calibrated reference leak to ensure accuracy.

The various electronic leak detectors are covered below. The information is not meant to steer you toward or away from any technology but is for information purposes only.

  • Ultrasonic — This approach uses sound amplification. It acts on the high-frequency sound pitch that occurs when gas passes through an orifice. This method may not be accurate on small leaks because not enough sound is generated through a small orifice.
  • Corona Discharge — Air is pulled through an energized electrical field around an electrode. Refrigerant gases are broken down by the electric arc (corona discharge) and detected by the sensor. The presence of a detectable gas changes the current flow in the electrode and triggers an alarm. Gases other than refrigerant can trigger an alarm, giving the appearance of a leak when there may not be one (false alarm). The sensor may degrade over time and need to be replaced. It should be checked regularly against a calibrated reference leak to ensure correct operation. Do not use in the presence of combustible gases.
  • Heated Diode — Air is pulled over a heated diode. Halogenated gases are broken down by the heater, resulting in a change in current flow through the diode. The change in current through the diode triggers an alarm. The heated diode sensor is sensitive to excess refrigerant in addition to other contaminates, such as moisture and oil, resulting in sensor degradation. Because of sensor degradation, the heated diode sensor must be checked regularly for accuracy and replaced within 100 hours of use. When exposed to contamination, including excess refrigerant, the sensor could fail much more quickly. For this reason, sensors must be checked regularly against a calibrated reference leak to ensure correct operation. Do not use in the presence of combustible gases.
  • Heated Electrolyte — Air is pulled over a heater that’s in the presence of an electrolytic material that reacts with the broken down halogenated refrigerant gasses. Halogenated gases result in a change in current flow between the heater electrode and the electrolyte that triggers an alarm. Like the heated diode sensor, the electrolytic sensor is sensitive to excess refrigerant and other contaminants, resulting in sensor degradation. Excess refrigerant exposure can have a quick impact on sensor life. A heated electrolyte detector must be checked regularly with a calibrated reference leak to ensure it can accurately detect a refrigerant leak. Do not use in the presence of combustible gases.
  • Infrared — Air is pulled through an optical window in the infrared sensor. Refrigerant gases absorb infrared (IR) radiation. The optical sensor senses this and triggers an alarm, depending on how much IR has been absorbed. This technology is very accurate and has been the technology of choice in lab settings for many years. It has only recently (last five years approximately) been introduced to the field in the form of portable hand-held leak detectors. The refrigerant isn’t broken down by heat and doesn’t directly contact the sensor, thus the sensor isn’t subject to contamination. Sensor life expectancy is over 1,000 hours or the life of the leak detector. To ensure accuracy, the infrared detector should be checked regularly against a calibrated reference leak.

Electronic leak detectors designed for use with HFC refrigerants, no matter what sensor type is utilized, when properly maintained (including sensor replacement when necessary), all work very well. Some are more susceptible to contamination, including exposure to excess refrigerant, than others. For this reason, never open a bottle of refrigerant and place the pickup tube in the refrigerant stream, as it can quickly ruin the sensor in your leak detector. Always use a calibrated reference leak to determine the accuracy of your sensor. Cfm Distributors Inc. has official calibrated reference leak devices available that attach directly to a jug of refrigerant and provide a leak reference equal to 5 grams (0.18oz) per year. These cost less than $195 to purchase and are required for ensuring an accurate leak detector and test method. If your leak detector will trigger on the reference leak, it’s capable of finding any leak in the system you are checking. If not, replace the sensor.

Some electronic detectors act on the total concentration of refrigerant gasses, and others act on a change in the concentration of refrigerant gases. It’s important that you know what type of meter you are using and how to correctly use it. Most sensor instruction manuals recommend moving the pickup tube over the unit being checked at a rate of 1-3 inches per second. If it triggers, make note of where it started and where it stopped. Reverse direction and again note the start and end points of detector notification. The leak should be midway between the trigger points. Never camp on a suspected leak, as your detector will automatically zero, and quit picking up the leak until you move away for a few seconds to let the detector reestablish a new zero point. After determining the general area of a leak with the use of an electronic detector, soap bubbles is a great method of pinpointing the exact location of the leak.

In summary, know what type of detector you are using, know how to use it, and ensure it is capable of detecting leaks by checking it against a calibrated reference leak on a regular basis.

Looking for quick answers on air conditioning, heating and refrigeration topics? Try Ask ACHR NEWS, our new smart AI search tool. Ask ACHR NEWS →

KEYWORDS: distribution professionals leak prevention service contractors service managers troubleshooting and HVACR

Share This Story

Looking for a reprint of this article?
From high-res PDFs to custom plaques, order your copy today!

 

Paul Flora is a service manager with cfm Distributors Inc.

Recommended Content

JOIN TODAY
To unlock your recommendations.

Already have an account? Sign In

  • HVAC-enrollment

    The Trades Are Back: HVACR Programs See Nearly 30% Enrollment Spike

    A new wave of future technicians is entering the pipeline.  
    Training and Education
    By: Matt Jachman
  • 2025 Top 40 Under 40

    2025 Top 40 Under 40 HVACR Professionals List

    The 11th annual Top 40 Under 40 list highlights those...
    HVAC Residential Market
    By: Hannah Belloli-Oster
  • LG Ductless Mini-Split Systems

    The 9 Types of Heat Pumps

    As the U.S. moves toward electrification, heat pumps are...
    HVAC Residential Market
    By: Joanna R. Turpin
Subscription Center
  • Create an Account
  • Start a Subscription
  • Manage My Account
  • Sign Up for Newsletters
  • Visit Customer Service
  • Update Preferences

More Videos

Sponsored Content

Sponsored Content is a special paid section where industry companies provide high quality, objective, non-commercial content around topics of interest to The News audience. All Sponsored Content is supplied by the advertising company and any opinions expressed in this article are those of the author and not necessarily reflect the views of The News or its parent company, BNP Media. Interested in participating in our Sponsored Content section? Contact your local rep!

close
  • Piggy Bank
    Sponsored byWatercress Financial

    Energy Prices, Inflation, and HVAC: What Today’s Homeowners Care About

  • Refrigerated Food
    Sponsored bySolstice Advanced Materials

    R-455A Refrigeration: A Cold Storage Solution for the Future

  • Airex Rooftop Units
    Sponsored byAirex Manufacturing Inc

    Consolidating Roof Penetrations: A Growing Trend in Multifamily HVAC Design

Popular Stories

HVAC-Price-Increase-graphic

HVAC Price Increase List: June 2026

Trump-Section-232.jpg

Trump Reduces Section 232 Tariffs on HVAC Equipment to 15%

Refrigerants-and-gauge.jpg

HVAC Industry Warns of Counterfeit Refrigerants Entering U.S. Supply Chain

Heat-pump-cutaway.jpg

PFAS Rules and A2L Building Codes Continue to Evolve

Midea-training.jpg

HVAC Workforce Crisis Expands Beyond Technicians to Instructor Shortages

View The ACHR NEWS
Centennial Anniversary Timeline

The ACHR News Timeline Chart
Submit a Letter
Submit a letter to our editors.

Events

November 6, 2025

Next-Gen Data Center Cooling: HVAC Innovation and Real-World Solutions

On Demand As AI workloads and high-density computing push traditional cooling methods to their limits, the data center industry is accelerating the adoption of next-generation HVAC technologies.

June 17, 2026

Decarbonization Without Disruption

This webinar will explore practical HVAC decarbonization strategies that minimize disruption while maximizing long-term performance and ROI.

View All Submit An Event

Poll

Summer Staff

Are you fully staffed for the summer season?
View Results Poll Archive

Products

BNI Mechanical/Electrical Square Foot Costbook, 2026 Edition

BNI Mechanical/Electrical Square Foot Costbook, 2026 Edition

See More Products
Decarbonization Without Disruption - Free Webinar - 6/17/2026

Related Articles

  • General Tools & Instruments Co. LLC: Refrigerant Leak Detector

    See More
  • Testo Inc.: Refrigerant Leak Detector

    See More
  • Extech Instruments: Refrigerant Leak Detector

    See More

Related Products

See More Products
  • low grade.png

    Low GWP Refrigerant Safety: Flammable & Mildly Flammable Refrigerants Manual

  • A-Heat-Pump-Thats-Not-Delivering-Any-Air-DVD-Cover-218x300.jpg

    A Heat Pump That’s Not Delivering Any Air

See More Products

Related Directories

  • CFM Equipment Distributors Inc.

    Wholesale Distributor covering Central and Northern California and Nevada.
  • Spectronics Corp./Spectroline Leak Detection

    Established in 1955, Spectronics Corporation is the inventor of UV fluorescent leak detection technology and manufacturer of leak detection tools for AC&R systems. Our fluorescent dyes and system additives are OEM-grade, universal (POE), co-solvent free, and NSF-certified.
×

Sign Up. Stay Informed.

The #1 trusted source for the HVACR industry since 1926

SUBSCRIBE
  • RESOURCES
    • Advertise
    • Contact Us
    • Advisory Board
    • Classifieds
    • Submit a Letter
    • Directories
    • Store
  • ACCOUNT CENTER
    • Create an Account
    • Start a Subscription
    • Manage My Account
    • Sign Up for Newsletters
    • Visit Customer Service
    • Update Preferences
  • SERVICES
    • Marketing Services
    • Reprints
    • Market Research
    • List Rental
    • Survey/Respondent Access
  • STAY CONNECTED
    • LinkedIn
    • Facebook
    • Instagram
    • YouTube
    • X (Twitter)
  • PRIVACY
    • PRIVACY POLICY
    • TERMS & CONDITIONS
    • DO NOT SELL MY PERSONAL INFORMATION
    • PRIVACY REQUEST
    • ACCESSIBILITY

Copyright ©2026. All Rights Reserved BNP Media, Inc. and BNP Media II, LLC.

Design, CMS, Hosting & Web Development :: ePublishing