ACHR News
search
Ask ACHR NEWS AI
cart
facebook twitter instagram linkedin youtube
  • Sign In
  • Subscribe
  • Sign Out
  • My Account
ACHR News
  • NEWS
    • Breaking News
    • New HVAC Products
    • Featured Products
    • Manufacturer Reports
    • HVAC Data
    • Legislation
    • ACHR NEWS Centennial
  • RESIDENTIAL
    • Air Conditioners
    • Furnaces
    • Residential Heat Pumps
    • Ductless
    • Residential IAQ
    • Testing, Monitoring, Tools
    • Components & Accessories
  • COMMERCIAL
    • Air Handlers
    • Rooftop Units
    • Chillers and Cooling Towers
    • Commercial Heat Pumps
    • Boilers and Hydronics
    • VRF/Ductless
    • Commercial IAQ
  • REFRIGERATION
    • Refrigerants
    • Refrigerant Regulations
    • Leak Management
  • CONTRACTOR PRO
    • Geothermal
    • Homeowner Study
    • VRF and VRV Ductless
    • Unitary Trends
  • EDUCATION
    • Training and Education
    • Business Management
    • Service and Maintenance
    • Continuing Education
    • Market Research >
      • HVAC Brand Awareness Report
      • VRV, VRF, VRVZ Report
      • Unitary Trends Report
      • Water Heat Professionals Report
    • Webinars
    • Sponsor Insights
    • eProducts Info
    • White Papers
  • EVENTS
    • HVAC Contractor Forum
    • Industry Events and Webinars
  • MEDIA
    • Videos
    • AHR Expo 2025 Videos
    • Podcasts >
      • ACHR News Podcast
      • HARDI Podcasts
      • AHR Expo Podcasts
      • ACCA Podcasts
    • Interactive Spotlights
    • Quizzes
    • eBooks
    • HVAC Talkback
  • HVAC GROUP
    • ACHR NEWS >
      • Current Issue
      • Digital Edition
      • Subscribe
    • Distribution Trends
    • SNIPS NEWS >
      • Join SNIPS NEWS
    • Engineered Systems News >
      • Join ES News
    • HVACR Directory
    • Contests
    • Newsletters
    • Contact
    • Advertise
    • My Account

UVC Helps Cut Heating Costs In Jails

By Barbara A. Checket-Hanks
January 16, 2006
Correctional facilities’ dense inmate population raises risks of disease outbreaks, such as TB, HIV, hepatitis, asthma, and antibiotic-resistant staph.
TACOMA, Wash. - If you think it's hard to get HVAC money for schools and similar public buildings, there is a harder nut to crack: correctional facilities. It can be even more difficult to get additional funds appropriated to improve conditions in buildings where people are incarcerated.

Compounding the problem, many correctional facility employees are in close proximity with the inmate community daily. Moreover, the dense inmate population raises the risks of disease outbreaks, including TB, HIV, hepatitis, asthma, and antibiotic-resistant staph, states the U.S. Federal Bureau of Prisons (BOP), which has been working to prevent/contain the spread of these and other diseases.

Because of TB's airborne transmission, the BOP points out, "The identification of a potentially infectious TB case in a correctional facility should always provoke a rapid response because of the potential for widespread TB transmission. Numerous outbreaks of TB have been reported in prisons and jails, especially among HIV-infected inmates."

According to the BOP, characteristics of TB exposure include:

  • Air volume - "The volume of air shared between an infectious TB patient and susceptible contacts is an important determinant in the risk of TB transmission," states the BOP. "The larger the air space, the more infectious particles are distributed and the less likely they are of being inhaled." However, the more ventilation air is used, the higher the cost of system operation, particularly when the outdoor air needs to be heated or cooled."

  • Ventilation - "Ventilation is an important factor in the risk of airborne transmission of disease," the bureau continues. "Exposures in confined air systems with little or no ventilation have been associated with increased TB transmission. The space where airborne infection spreads includes all space sharing the same air. Thus, if air circulates from the room occupied by an infectious patient into other rooms, their occupants will also be exposed."

  • Duration of exposure - TB transmission can occur after even a brief exposure, but the longer or more often a person is exposed to an infectious person, the greater the likelihood that person will also become infected.

    According to the BOP, "certain risks and conditions, such as HIV infection, diabetes, chronic renal failure, injection drug use history, and close contact with someone who is sick with infectious TB, all pose a greater risk for getting TB disease."

    There are additional ventilation design considerations, not the least of which is security.

    According to the American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE), correctional facilities "must also consider compliance with all of the regulations that may affect their mission to protect the general population by securely housing the criminal offenders of the state. Security issues or the original structure of earlier facilities may prevent certain ventilation practices from being incorporated into existing facility designs. The building owner/operator should prioritize projects based on the criteria above and complete those projects based on hazard concerns and financial ability."

    Again, it comes back to being a question of money and population safety.

    Jim Loewen, project manager for the department of facilities management at Pierce County, shows some of the Steril-Aire UVC lamps installed opposite the cooling coils in the Tacoma jail’s air-handling units.

    A SPECIFIC CASE

    Facilities management officials in Pierce County, Wash., wanted to find a way to reduce natural gas heating costs at the existing Tacoma jail as well as in a new addition, without compromising the indoor air quality, or perhaps even improving it.

    In this case, the addition of ultraviolet-C (UVC) lamps in the air-handling systems helped meet these dual challenges.

    The UVC energy emitted by the lamps helps disinfect the air, making it possible to recirculate a portion of the indoor air while simultaneously killing viruses, bacteria, and mold for enhanced air quality, states manufacturer Steril-Aire Inc. (Burbank, Calif.). Plus, the use of the technology is said to be saving the county an estimated $55,000 net annually.

    "With the jail occupied to full capacity on a 24/7 basis, we previously had to bring in 100 percent outside air, which was very costly to heat," explained Jim Loewen, project manager for the Department of Facilities Management at Pierce County.

    "Back in 2001, we did extensive research on UVC disinfection, and we predicted that we could safely recirculate up to 30 percent of the jails' ventilation air by installing UVC lamps in the air-handling systems," he continued. By recirculating 30 percent of ventilation air, the county stood to save 34,102 therms of natural gas a year at the older jail, and another 39,491 therms at the neighboring addition that was under construction at the time.

    Loewen learned that Puget Sound Energy's (PSE's) energy-efficiency program would cover half the cost of the initial UVC installation.

    INSTALLATION AND CONTROL

    In late 2002, more than 100 Steril-Aire UVC lamps were installed in the two facilities, opposite the cooling coils in the air-handling units (AHUs).

    The AHUs consist of dedicated systems for each inmate cell area - mostly single-fan systems built up with heating and cooling, Loewen said. On one air handler, where there is no cooling coil on the fan, the lamps are installed in the variable air volume (VAV) boxes instead.

    The systems are tied into Honeywell controls; CO2 sensors increase or decrease air recirculation as needed, to a maximum of 30 percent recirculated air.

    Installed in these locations, the high-output UVC energy continuously kills bacteria, viruses, and other microbes, and helps to prevent them from spreading through the occupied space. The UVC is also said to kill mold and organic debris that may build up on the surfaces of the cooling coils. According to the manufacturer, the mold control has a dual advantage:

    1. It helps the coils stay clean, which allows them to perform more efficiently.

    2. It prevents mold-related allergens from recirculating through the building.

    TUBE MAINTENANCE

    According to the manufacturer, UVC output or intensity diminishes over time. The light tubes are replaced annually according to manufacturer's recommendations, so that sufficient output will be maintained, delivering the desired germicidal effect.

    The maintenance crew at the jail also performs quarterly visual inspections, at the time of air filter change-out, to make sure all lamps are functioning with no sign of damage.

    To use UVC successfully, Pierce County officials noted that certain precautions should be observed. "Always follow the manufacturer's guidelines for proper lamp sizing, location, and spacing within the system," advised Loewen. "If the lamps are not applied correctly, they may not perform as expected."

    In addition, prolonged direct exposure to UVC (like other parts of the UV spectrum) can be harmful, so protective eyewear is necessary during maintenance and inspection. Safety signage should be posted on the air handlers so that service technicians know to turn the UVC lamps off when they are working inside the units. An additional solution is to use lockout switches that automatically turn the lights off when a unit door is opened.

    As another precaution, Pierce County wrapped exposed wiring and pneumatic lines in tin foil to protect them from potential UV degradation over time.

    UVC energy emitted is said to help disinfect the air, making it possible to recirculate a portion of the indoor air while killing viruses, bacteria, and mold.

    BENEFITS AND SAVINGS

    Bob Hamilton, maintenance supervisor for the corrections facilities at Pierce County, said he was the biggest skeptic in the room when UVC was first discussed. "I was concerned that the big reduction in outdoor air would result in odor problems," he noted. "We were considering the use of carbon filtration to offset any potential problems.

    "We have found, however, that the UVC lamps do a good job of controlling odors, so we haven't needed the additional filtration."

    Hamilton also stated, "The condensate pans are cleaner, and the algae growth we sometimes used to see on the coils is no longer evident. Coils have a cleaner, shinier appearance." He noted that, prior to installing UVC, they would brush the coils every three months and perform pressure washing annually. Now that the coils stay cleaner, Hamilton said he has cut back on the frequency of these coil-cleaning procedures, although these savings have not yet been quantified.

    "A review of our utility bills confirms that we have saved more than $70,000 a year in natural gas by reducing our outdoor air requirement through the use of UVC technology," reported Loewen.

    "Even after we subtract the parts and labor costs for servicing and changing the UVC lamps, annual savings still exceed $55,000."

    Loewen added that the lamps have created a healthier and more comfortable environment. "People used to call all the time, saying it was either too hot and stuffy, or too cold in the jail. We are not getting those phone calls anymore.

    "Overall, we believe UVC technology is meeting our expectations for energy savings and enhanced IAQ," he said. "Another stakeholder in the process, the Corrections Officers' Union, has been monitoring the program, and I believe they are pleased with the results as well.

    "Energy savings and good IAQ are often regarded as conflicting goals, but with the use of UVC we have found it possible to achieve both objectives at the same time."

    Publication date: 01/16/2006

  • Looking for quick answers on air conditioning, heating and refrigeration topics? Try Ask ACHR NEWS, our new smart AI search tool. Ask ACHR NEWS →

    Share This Story

    Looking for a reprint of this article?
    From high-res PDFs to custom plaques, order your copy today!

     

    Barbara Checket-Hanks is Service & Maintenance Editor. E-mail her at barbarachecket-hanks@achrnews.com.

    Recommended Content

    JOIN TODAY
    To unlock your recommendations.

    Already have an account? Sign In

    • HVAC-enrollment

      The Trades Are Back: HVACR Programs See Nearly 30% Enrollment Spike

      A new wave of future technicians is entering the pipeline.  
      News
      By: Matt Jachman
    • 2025 Top 40 Under 40

      2025 Top 40 Under 40 HVACR Professionals List

      The 11th annual Top 40 Under 40 list highlights those...
      HVAC Contracting
      By: Hannah Belloli-Oster
    • LG Ductless Mini-Split Systems

      The 9 Types of Heat Pumps

      As the U.S. moves toward electrification, heat pumps are...
      Ground Source Heat Pumps
      By: Joanna R. Turpin
    Subscription Center
    • Create an Account
    • Start a Subscription
    • Manage My Account
    • Sign Up for Newsletters
    • Visit Customer Service
    • Update Preferences

    More Videos

    Sponsored Content

    Sponsored Content is a special paid section where industry companies provide high quality, objective, non-commercial content around topics of interest to The News audience. All Sponsored Content is supplied by the advertising company and any opinions expressed in this article are those of the author and not necessarily reflect the views of The News or its parent company, BNP Media. Interested in participating in our Sponsored Content section? Contact your local rep!

    close
    • Piggy Bank
      Sponsored byWatercress Financial

      Energy Prices, Inflation, and HVAC: What Today’s Homeowners Care About

    • Refrigerated Food
      Sponsored bySolstice Advanced Materials

      R-455A Refrigeration: A Cold Storage Solution for the Future

    • Airex Rooftop Units
      Sponsored byAirex Manufacturing Inc

      Consolidating Roof Penetrations: A Growing Trend in Multifamily HVAC Design

    Popular Stories

    Outdoor-condensing-units.jpg

    EPA Removes R-410A Installation Deadline

    HVAC-Price-Increase-graphic

    HVAC Price Increase List: June 2026

    Trump-Section-232.jpg

    Trump Reduces Section 232 Tariffs on HVAC Equipment to 15%

    ACHR NEWS Editor Chris Gray Presenting HVAC Minute 5-18-2026

    HVAC Manufacturers Fight Pricing Lawsuits

    R410A-Refrigerant-Cylinder.jpg

    Refrigerant Recovery is a Revenue Opportunity

    View The ACHR NEWS
    Centennial Anniversary Timeline

    The ACHR News Timeline Chart
    Submit a Letter
    Submit a letter to our editors.

    Events

    November 6, 2025

    Next-Gen Data Center Cooling: HVAC Innovation and Real-World Solutions

    On Demand As AI workloads and high-density computing push traditional cooling methods to their limits, the data center industry is accelerating the adoption of next-generation HVAC technologies.

    June 9, 2026

    Before You Go All In on AI: Set Up Your Business to Actually Win

    In this webinar, we'll walk you through exactly what to get in place before you add AI to your business. You'll leave with a clear picture of where you stand today and a practical action plan to set yourself up for real results.

    View All Submit An Event

    Poll

    Summer Staff

    Are you fully staffed for the summer season?
    View Results Poll Archive

    Products

    BNI Mechanical/Electrical Square Foot Costbook, 2026 Edition

    BNI Mechanical/Electrical Square Foot Costbook, 2026 Edition

    See More Products
    A2L Refrigerants - Free Webinar - May 21, 2026

    Related Articles

    • Fabric Duct Helps Cut Costs On Pool Project

      See More
    • Honeywell Helps Schools Cut Costs

      See More
    • Product Helps Cut Gas-Line Installation Time By Two-Thirds

      See More

    Related Products

    See More Products
    • EHEP002028.jpg

      Principles of Heating, Ventilation, and Air Conditioning in Buildings, 1st Edition

    • ghpm.png

      Gas Heating: Furnaces, Boilers, Controls, Components

    • Lessons Learned in a Boiler Room: A common sense approach to servicing and installing commercial boilers

    See More Products

    Related Directories

    • HUG Hydronics In-Floor Heating

      HUG Hydronics makes in-floor heating simple! We have all you need from walk-in PEX pipe insulation (HeatSheet), to PEX, organizers, layout service, and our revolutionary distribution system that installs in 1 hour!
    • Advance Cutting Systems (Manufacturer)

      Advance Cutting Systems has been a leading supplier to the HVAC industry for 40 years specializing in plasma, laser, and waterjet systems, and coil lines.
    ×

    Sign Up. Stay Informed.

    The #1 trusted source for the HVACR industry since 1926

    SUBSCRIBE
    • RESOURCES
      • Advertise
      • Contact Us
      • Advisory Board
      • Classifieds
      • Submit a Letter
      • Directories
      • Store
    • ACCOUNT CENTER
      • Create an Account
      • Start a Subscription
      • Manage My Account
      • Sign Up for Newsletters
      • Visit Customer Service
      • Update Preferences
    • SERVICES
      • Marketing Services
      • Reprints
      • Market Research
      • List Rental
      • Survey/Respondent Access
    • STAY CONNECTED
      • LinkedIn
      • Facebook
      • Instagram
      • YouTube
      • X (Twitter)
    • PRIVACY
      • PRIVACY POLICY
      • TERMS & CONDITIONS
      • DO NOT SELL MY PERSONAL INFORMATION
      • PRIVACY REQUEST
      • ACCESSIBILITY

    Copyright ©2026. All Rights Reserved BNP Media, Inc. and BNP Media II, LLC.

    Design, CMS, Hosting & Web Development :: ePublishing