ACHR News
search
Ask ACHR NEWS AI
cart
facebook twitter instagram linkedin youtube
  • Sign In
  • Subscribe
  • Sign Out
  • My Account
ACHR News
  • NEWS
    • Breaking News
    • New HVAC Products
    • Featured Products
    • Manufacturer Reports
    • HVAC Data
    • Legislation
    • ACHR NEWS Centennial
  • RESIDENTIAL
    • Air Conditioners
    • Furnaces
    • Residential Heat Pumps
    • Ductless
    • Residential IAQ
    • Testing, Monitoring, Tools
    • Components & Accessories
  • COMMERCIAL
    • Air Handlers
    • Rooftop Units
    • Chillers and Cooling Towers
    • Commercial Heat Pumps
    • Boilers and Hydronics
    • VRF/Ductless
    • Commercial IAQ
  • REFRIGERATION
    • Refrigerants
    • Refrigerant Regulations
    • Leak Management
  • CONTRACTOR PRO
    • Geothermal
    • Homeowner Study
    • VRF and VRV Ductless
    • Unitary Trends
  • EDUCATION
    • Training and Education
    • Business Management
    • Service and Maintenance
    • Continuing Education
    • Market Research >
      • HVAC Brand Awareness Report
      • VRV, VRF, VRVZ Report
      • Unitary Trends Report
      • Water Heat Professionals Report
    • Webinars
    • Sponsor Insights
    • eProducts Info
    • White Papers
  • EVENTS
    • HVAC Contractor Forum
    • Industry Events and Webinars
  • MEDIA
    • Videos
    • AHR Expo 2025 Videos
    • Podcasts >
      • ACHR News Podcast
      • HARDI Podcasts
      • AHR Expo Podcasts
      • ACCA Podcasts
    • Interactive Spotlights
    • Quizzes
    • eBooks
    • HVAC Talkback
  • HVAC GROUP
    • ACHR NEWS >
      • Current Issue
      • Digital Edition
      • Subscribe
    • Distribution Trends
    • SNIPS NEWS >
      • Join SNIPS NEWS
    • Engineered Systems News >
      • Join ES News
    • HVACR Directory
    • Contests
    • Newsletters
    • Contact
    • Advertise
    • My Account

Primary And Secondary Winding Configurations

July 1, 2003
Figure 1. A three-phase service transformer with a Delta primary and a Delta secondary. Primary line voltage = 2,400 V. Primary phase voltage = 2,400 V. Secondary line voltage = 2,400 divided by 10 = 240 V. Secondary phase voltage = line voltage = 240 V.
A thorough understanding of Delta and Wye service transformers, their primary and secondary windings, and their windings’ voltages, will help HVACR service technicians in their understanding of electrical troubleshooting.

Previous articles (March 3, April 7, and June 2, 2003) covered both the Delta and Wye service transformer’s secondary windings and secondary winding voltages. This article will include primary winding voltages along with the secondary winding voltages. A mathematical formula called the “turns ratio” will also be covered, as well as a mixture of Delta and Wye configurations.

Power is supplied through three-phase circuits containing transformers in which the primary and secondary windings are connected in different Wye and Delta configurations. The four possible configurations are:

1. Primary in Delta to secondary in Delta;

2. Primary in Wye to secondary in Delta;

3. Primary in Delta to secondary in Wye; and

4. Primary in Wye to secondary in Wye.

Figure 2. A three-phase service transformer with a Wye primary and a Delta secondary. Primary line voltage = 3,984 V. Primary phase voltage = 3,984 divided by 1.73 = 2,302 V. Secondary line voltage = 2,302 divided by 10 = 230 V. Secondary phase voltage = line voltage, 230 V.
It is important to realize that no matter what configuration we are dealing with, the voltage from the primary windings to the secondary winding is the “induced” voltage. The wires of the primary winding do not touch the secondary winding wires. However, they are in very close proximity.

Induced voltage means that the pulsating electromagnetic force field coming from the primary windings cuts through the secondary windings and produces an electromagnetic force for voltage in the secondary windings without physically touching it. The pulsations of the building and collapsing electromagnetic field come from the alternating current and alternating voltage delivered to the primary windings.

The following are four examples of induced voltage with different configurations of windings.

Looking for quick answers on air conditioning, heating and refrigeration topics? Try Ask ACHR NEWS, our new smart AI search tool. Ask ACHR NEWS →

1. Primary In Delta To Secondary In Delta

Figure 1 shows a three-phase service transformer with a Delta primary and a Delta secondary. The ratio of turns of windings from the primary to the secondary is 10 to 1, thus it has a 10:1 turns ratio. This means that the primary windings have 10 times more turns than the secondary.

This turns ratio will cause a voltage drop from the primary to the secondary windings because of the reduced turns of wires in the secondary windings. Fewer turns of wire cause less electromagnetic force field to be intercepted in the secondary windings.

In previous articles, I explained that line voltage and phase voltage are the same in a Delta configuration. This is because one phase is between the two lines of power – therefore, line voltage equals phase voltage for both primary and secondary windings of the transformer. This will not hold true for the Wye configuration, which will be covered later in this article.

Figure 3. The Wye configuration: note that between two lines lie two phases, which are 120 degrees apart.
2. Primary In Wye To Secondary In Delta

Figure 2 shows a three-phase service transformer with a Wye primary and a Delta secondary. It has a 10:1 turns ratio. In the Wye configuration, the line voltage is not equal to the phase voltage.

Figure 3 shows that between two lines lie two phases, which are 120 degrees apart. Thus, line voltage cannot equal phase voltage. The phase voltages will be less than line voltages.

Phase voltage equals line voltage divided by 1.73. The 1.73 is the same as the square root of 3, which comes from a trigonometric function cosine. It takes higher mathematics to understand the origin of 1.73. It is always the phase voltages that are induced into the second windings of the transformer (Figure 2).

Figure 4. A three-phase transformer with a Wye primary and a Wye secondary. Primary line voltage = 2,400 V. Primary phase voltage = 2,400 divided by 1.73 = 1,387 V. Secondary phase voltage = 1,387 divided by 10 = 139 V. Secondary line voltage = 139 V multiplied by 1.73 = 240 V.
3. Primary In Delta To Secondary In Wye

In a three-phase service transformer with a Delta primary and a Wye secondary, there is a 20:1 turns ratio. In the Delta primary, the line voltage equals the phase voltage. In the secondary, however, the line voltage and the phase voltage differ by the factor 1.73. This is because between any two lines, there are two phases that are 120 degrees apart. Notice that the phase voltage of 120 V is less than the line voltage of 208 V.

4. Primary In Wye To Secondary In Wye

Figure 4 shows a three-phase transformer with a Wye primary and a Wye secondary. There is a 10:1 turns ratio. Notice that both in the primary and secondary windings there are different phase and line voltages. It is only in a Delta configuration that the line voltage is equal to the phase voltage.

John Tomczyk is a professor of HVAC at Ferris State University, Big Rapids, Mich. He can be reached at tomczykj@tucker-usa.com.

Publication date: 07/07/2003

Share This Story

Looking for a reprint of this article?
From high-res PDFs to custom plaques, order your copy today!

 

Recommended Content

JOIN TODAY
To unlock your recommendations.

Already have an account? Sign In

  • HVAC-enrollment

    The Trades Are Back: HVACR Programs See Nearly 30% Enrollment Spike

    A new wave of future technicians is entering the pipeline.  
    News
    By: Matt Jachman
  • 2025 Top 40 Under 40

    2025 Top 40 Under 40 HVACR Professionals List

    The 11th annual Top 40 Under 40 list highlights those...
    HVAC Light Commercial Market
    By: Hannah Belloli-Oster
  • LG Ductless Mini-Split Systems

    The 9 Types of Heat Pumps

    As the U.S. moves toward electrification, heat pumps are...
    HVAC Residential Market
    By: Joanna R. Turpin
Subscription Center
  • Create an Account
  • Start a Subscription
  • Manage My Account
  • Sign Up for Newsletters
  • Visit Customer Service
  • Update Preferences

More Videos

Sponsored Content

Sponsored Content is a special paid section where industry companies provide high quality, objective, non-commercial content around topics of interest to The News audience. All Sponsored Content is supplied by the advertising company and any opinions expressed in this article are those of the author and not necessarily reflect the views of The News or its parent company, BNP Media. Interested in participating in our Sponsored Content section? Contact your local rep!

close
  • Piggy Bank
    Sponsored byWatercress Financial

    Energy Prices, Inflation, and HVAC: What Today’s Homeowners Care About

  • Refrigerated Food
    Sponsored bySolstice Advanced Materials

    R-455A Refrigeration: A Cold Storage Solution for the Future

  • Airex Rooftop Units
    Sponsored byAirex Manufacturing Inc

    Consolidating Roof Penetrations: A Growing Trend in Multifamily HVAC Design

Popular Stories

HVAC-Price-Increase-graphic

HVAC Price Increase List: June 2026

Trump-Section-232.jpg

Trump Reduces Section 232 Tariffs on HVAC Equipment to 15%

R410A-Refrigerant-Cylinder.jpg

Refrigerant Recovery is a Revenue Opportunity

Heat-pump-cutaway.jpg

PFAS Rules and A2L Building Codes Continue to Evolve

Midea-training.jpg

HVAC Workforce Crisis Expands Beyond Technicians to Instructor Shortages

View The ACHR NEWS
Centennial Anniversary Timeline

The ACHR News Timeline Chart
Submit a Letter
Submit a letter to our editors.

Events

November 6, 2025

Next-Gen Data Center Cooling: HVAC Innovation and Real-World Solutions

On Demand As AI workloads and high-density computing push traditional cooling methods to their limits, the data center industry is accelerating the adoption of next-generation HVAC technologies.

June 17, 2026

Decarbonization Without Disruption

This webinar will explore practical HVAC decarbonization strategies that minimize disruption while maximizing long-term performance and ROI.

View All Submit An Event

Poll

Summer Staff

Are you fully staffed for the summer season?
View Results Poll Archive

Products

BNI Mechanical/Electrical Square Foot Costbook, 2026 Edition

BNI Mechanical/Electrical Square Foot Costbook, 2026 Edition

See More Products
Decarbonization Without Disruption - Free Webinar - 6/17/2026

Related Articles

  • Oct. 25, 2013: Seminar on Primary/Secondary Pumping and Control Offered by Taco

    See More
  • surplus in warehouse.jpeg

    Refrigerant Rules Fuel Demand for R-410A Equipment and Secondary Market Sales

    See More
  • Chiller and pumps

    The Three Stages to Controlling a Chiller and its Primary-Secondary Pumps

    See More

Related Products

See More Products
  • 9781482255676.jpg

    Testing and Balancing HVAC Air and Water Systems, Fifth Edition

  • Manual B.jpg

    Manual B - Balancing and Testing Air and Hydronic Systems

  • Building Information Modeling: Planning and Managing Construction Projects with 4D CAD and Simulations

See More Products

Related Directories

  • WindGate Products Co. Inc.

    Pioneers in air regulation hardware and components, we have been leading the way by innovating industry-first products. To experience WindGate first-hand, contact us for a free sample packet.
×

Sign Up. Stay Informed.

The #1 trusted source for the HVACR industry since 1926

SUBSCRIBE
  • RESOURCES
    • Advertise
    • Contact Us
    • Advisory Board
    • Classifieds
    • Submit a Letter
    • Directories
    • Store
  • ACCOUNT CENTER
    • Create an Account
    • Start a Subscription
    • Manage My Account
    • Sign Up for Newsletters
    • Visit Customer Service
    • Update Preferences
  • SERVICES
    • Marketing Services
    • Reprints
    • Market Research
    • List Rental
    • Survey/Respondent Access
  • STAY CONNECTED
    • LinkedIn
    • Facebook
    • Instagram
    • YouTube
    • X (Twitter)
  • PRIVACY
    • PRIVACY POLICY
    • TERMS & CONDITIONS
    • DO NOT SELL MY PERSONAL INFORMATION
    • PRIVACY REQUEST
    • ACCESSIBILITY

Copyright ©2026. All Rights Reserved BNP Media, Inc. and BNP Media II, LLC.

Design, CMS, Hosting & Web Development :: ePublishing