ACHR News
search
Ask ACHR NEWS AI
cart
facebook twitter instagram linkedin youtube
  • Sign In
  • Subscribe
  • Sign Out
  • My Account
ACHR News
  • NEWS
    • Breaking News
    • New HVAC Products
    • Featured Products
    • Manufacturer Reports
    • HVAC Data
    • Legislation
    • ACHR NEWS Centennial
  • RESIDENTIAL
    • Air Conditioners
    • Furnaces
    • Residential Heat Pumps
    • Ductless
    • Residential IAQ
    • Testing, Monitoring, Tools
    • Components & Accessories
  • COMMERCIAL
    • Air Handlers
    • Rooftop Units
    • Chillers and Cooling Towers
    • Commercial Heat Pumps
    • Boilers and Hydronics
    • VRF/Ductless
    • Commercial IAQ
  • REFRIGERATION
    • Refrigerants
    • Refrigerant Regulations
    • Leak Management
  • CONTRACTOR PRO
    • Geothermal
    • Homeowner Study
    • VRF and VRV Ductless
    • Unitary Trends
  • EDUCATION
    • Training and Education
    • Business Management
    • Service and Maintenance
    • Continuing Education
    • Market Research >
      • HVAC Brand Awareness Report
      • VRV, VRF, VRVZ Report
      • Unitary Trends Report
      • Water Heat Professionals Report
    • Webinars
    • Sponsor Insights
    • eProducts Info
    • White Papers
  • EVENTS
    • HVAC Contractor Forum
    • Industry Events and Webinars
  • MEDIA
    • Videos
    • AHR Expo 2025 Videos
    • Podcasts >
      • ACHR News Podcast
      • HARDI Podcasts
      • AHR Expo Podcasts
      • ACCA Podcasts
    • Interactive Spotlights
    • Quizzes
    • eBooks
    • HVAC Talkback
  • HVAC GROUP
    • ACHR NEWS >
      • Current Issue
      • Digital Edition
      • Subscribe
    • Distribution Trends
    • SNIPS NEWS >
      • Join SNIPS NEWS
    • Engineered Systems News >
      • Join ES News
    • HVACR Directory
    • Contests
    • Newsletters
    • Contact
    • Advertise
    • My Account

Service Hotline: 10/01/2001

By Peter Powell
September 25, 2001

Line Temperature

Question:

From Rick Dempster Columbia, SC

When checking subcooling on an a/c system, should you check the pressure reading on the discharge line or the liquid line? Where is the best place to take the temperature of the line?

Answer:

By Dan Kramer P.E. Specialist Grade Member of RSES and Professional Engineer

It is always best to take the pressure at or very near the point where you will be measuring the temperature. This is because there can be either a significant pressure drop or even a pressure rise between the point where you measure the pressure and the point where you measure the temperature.

For example, suppose in an R-134a system there is a 5-psi pressure drop through the condenser. You measured 114 psig at the condenser inlet and 92.5?F at the condenser liquid outlet. You might calculate 2? to 3? sub-cooling when there was none.

On the other hand, let’s consider a condensing unit on the roof, 15 ft above grade. If you measured the liquid line pressure at the receiver outlet and the liquid temperature at the evaporator inlet on grade, you would have a pressure at the point of measurement about 7 psi higher than at the point of pressure measurement at the receiver outlet. Your measured temperature might then incorrectly indicate zero subcooling when there was really several degrees of subcooling. Of course, a liquid sight glass showing clear liquid at that point might help to raise a question about the correctness of that zero subcooling measurement.

If you were hearing periodic hissing at the thermostatic expansion valve (TXV) and possibly observing a starved evaporator, you might suspect little or no subcooling at the TXV inlet. It would be important to measure the pressure and temperature right there at the TXV inlet. This is because of the possibility (or even probability) of a restricted liquid line filter-drier causing a pressure drop and liquid flashing (zero subcooling).



Refrigerant Odors

Question:

From J. Schilling Via e-mail

Looking for quick answers on air conditioning, heating and refrigeration topics? Try Ask ACHR NEWS, our new smart AI search tool. Ask ACHR NEWS →

I seem to be able to smell a chemical odor when I open the freezer door. I think it could be the refrigerant. The food that is in the refrigerator compartment is picking up this odor. Does refrigerant have an odor and do you know what affect this could have on my family?

Answer:

By Gary Zyhowski Genetron Refrigerants Technical Service Honeywell Buffalo, NY

Fluorocarbons are most often described as having a faint ether-like odor. Since foods also give off odors and the ability to smell odors varies with the individual, you don’t want to rely on your nose.

I would suggest having a service person check the system for leaks. Domestic refrigerator/freezers have a small refrigerant charge. If you did detect the presence of refrigerant, there may not be much left in the system now.

I would not expect the level of exposure to the refrigerants R-12 or R-134a commonly used in domestic systems to be a concern. Prior to the ban on CFCs, R-12 was used in direct-contact food freezing. In the case of 134a, it is currently used in metered-dose inhalers as a way to deliver, for example, asthma medication directly to the lungs.

Depending on the design of the refrigerator/freezer, there is also a possibility that a leak may have introduced compressor lubricant into the compartment. You may want to have a service person check for this possibility as well.



Voltage Imbalance

Question:

Rick Sones Vatterott College Des Moines, IA

I am an instructor at a technical college in Des Moines, IA, and I have a question. I cannot for the life of me remember how to figure voltage imbalance on a three-phase system.

This question is so basic that I must be overlooking a very simple step. I am trying to find the percentage of unbalance between the three legs of power.

Answer:

Gary Weeks SSAC Inc. Baldwinsville, NY

The effect that unbalanced voltages and currents have on three-phase motors is widely misunderstood. Not enough technicians and controls engineers understand the number of motor failures that are actually caused by unbalanced voltages.

Most understand the effect of phase loss (the most extreme level of unbalance possible), but don’t recognize the cumulative effect of moderate unbalance events.

Unbalanced voltage causes over-heating of a three-phase induction motor’s stator windings and rotor bars. When the voltages are unbalanced, the currents are unbalanced by six to 10 times the percent of voltage un-balance. A 5% voltage unbalance can mean a 30% to 50% current unbalance.

With currents unbalanced at these levels, the motor will begin to overheat and slip as if it was overloaded. The effect of overheating is said to be equal to twice the square of the unbalanced percentage. Often, when the voltages are unbalanced, the average voltage is also low, so a normal 100% load will appear like an overload to the motor. This is why is it always important to derate the motor’s horsepower when unbalances are present.

The best idea is to eliminate the unbalance so that the motor can operate without overheating. This is usually accomplished by redistributing the single-phase loads on the three-phrase supply transformer.

It is unfortunate that more technicians don’t understand how often unbalance and low voltage occur together. Too often, failures caused by repeated exposure to these events are blamed on a mysterious single-phase event or an overload that never actually occurs. SSAC manufactures voltage and current monitors that can detect unbalance, single phasing, low voltage, high voltage, and phase reversal. Some models also include overload protection. These provide three-phase motor protection and can eliminate failures caused by three events.

Unbalanced voltages are covered in NEMA motor specifications. It is relatively easy to calculate the percentage of unbalance. The most commonly used formula is also included in the NEMA guideline. That states that the percentage of voltage unbalance equals 100 times the maximum voltage deviation from average voltage, divided by the average voltage. For example, with voltages of 460, 467, and 450, the average is 459. The maximum deviation from average is 9 and the percentage unbalance = 100 x 9 over 459 = 1.96%.

This same formula can be used to calculate the percentage of current unbalance by substituting current readings for the voltage readings.

SSAC also has a training manual that shows the relationship between unbalance and overheating. That includes a graph that shows the relationship between overheating and motor insulation life span.

Voltage monitors are controls that provide much-needed protection for hvacr compressor systems. Their values have been proven for years in the field. Most systems include a voltage monitor so every hvacr technician needs to understand what they do and how they protect a three-phrase motor against premature failure.

Publication date: 10/01/2001

Share This Story

Looking for a reprint of this article?
From high-res PDFs to custom plaques, order your copy today!

 

Peter Powell is Refrigeration Editor. He can be contacted at 815-654-7270 or peterpowell@achrnews.com. Peter was formerly Editor/Publisher of Service & Contracting, where he gained his refrigeration experience. Among his duties, Powell is responsible for the monthly Refrigeration Zone sections in The NEWS

Recommended Content

JOIN TODAY
To unlock your recommendations.

Already have an account? Sign In

  • HVAC-enrollment

    The Trades Are Back: HVACR Programs See Nearly 30% Enrollment Spike

    A new wave of future technicians is entering the pipeline.  
    Training and Education
    By: Matt Jachman
  • 2025 Top 40 Under 40

    2025 Top 40 Under 40 HVACR Professionals List

    The 11th annual Top 40 Under 40 list highlights those...
    HVAC Contracting
    By: Hannah Belloli-Oster
  • LG Ductless Mini-Split Systems

    The 9 Types of Heat Pumps

    As the U.S. moves toward electrification, heat pumps are...
    Ground Source Heat Pumps
    By: Joanna R. Turpin
Subscription Center
  • Create an Account
  • Start a Subscription
  • Manage My Account
  • Sign Up for Newsletters
  • Visit Customer Service
  • Update Preferences

More Videos

Sponsored Content

Sponsored Content is a special paid section where industry companies provide high quality, objective, non-commercial content around topics of interest to The News audience. All Sponsored Content is supplied by the advertising company and any opinions expressed in this article are those of the author and not necessarily reflect the views of The News or its parent company, BNP Media. Interested in participating in our Sponsored Content section? Contact your local rep!

close
  • Piggy Bank
    Sponsored byWatercress Financial

    Energy Prices, Inflation, and HVAC: What Today’s Homeowners Care About

  • Refrigerated Food
    Sponsored bySolstice Advanced Materials

    R-455A Refrigeration: A Cold Storage Solution for the Future

  • Airex Rooftop Units
    Sponsored byAirex Manufacturing Inc

    Consolidating Roof Penetrations: A Growing Trend in Multifamily HVAC Design

Popular Stories

HVAC-Price-Increase-graphic

HVAC Price Increase List: June 2026

Trump-Section-232.jpg

Trump Reduces Section 232 Tariffs on HVAC Equipment to 15%

Refrigerants-and-gauge.jpg

HVAC Industry Warns of Counterfeit Refrigerants Entering U.S. Supply Chain

Heat-pump-cutaway.jpg

PFAS Rules and A2L Building Codes Continue to Evolve

Midea-training.jpg

HVAC Workforce Crisis Expands Beyond Technicians to Instructor Shortages

View The ACHR NEWS
Centennial Anniversary Timeline

The ACHR News Timeline Chart
Submit a Letter
Submit a letter to our editors.

Events

November 6, 2025

Next-Gen Data Center Cooling: HVAC Innovation and Real-World Solutions

On Demand As AI workloads and high-density computing push traditional cooling methods to their limits, the data center industry is accelerating the adoption of next-generation HVAC technologies.

June 17, 2026

Decarbonization Without Disruption

This webinar will explore practical HVAC decarbonization strategies that minimize disruption while maximizing long-term performance and ROI.

View All Submit An Event

Poll

Summer Staff

Are you fully staffed for the summer season?
View Results Poll Archive

Products

BNI Mechanical/Electrical Square Foot Costbook, 2026 Edition

BNI Mechanical/Electrical Square Foot Costbook, 2026 Edition

See More Products
Decarbonization Without Disruption - Free Webinar - 6/17/2026

Related Articles

  • Service Hotline - 01/08/2001: Charge It and Wet Systems

    See More
  • Service Hotline - April 2, 2001: Sight Glass

    See More
  • Service Hotline: 12/03/2001

    See More

Related Products

See More Products
  • Manual_SPS_new.jpg

    Manual SPS HVAC Design for Swimming Pools and Spas [ANSI/ACCA 10 Manual SPS - 2010 (RA 2017)]

See More Products

Related Directories

  • Service Logic

    Headquartered in Charlotte, Service Logic is the largest privately held HVAC company, with more than 120 locations, in the US and Canada. Our HVAC services optimize energy efficiency, comfort, productivity, health and safety.
×

Sign Up. Stay Informed.

The #1 trusted source for the HVACR industry since 1926

SUBSCRIBE
  • RESOURCES
    • Advertise
    • Contact Us
    • Advisory Board
    • Classifieds
    • Submit a Letter
    • Directories
    • Store
  • ACCOUNT CENTER
    • Create an Account
    • Start a Subscription
    • Manage My Account
    • Sign Up for Newsletters
    • Visit Customer Service
    • Update Preferences
  • SERVICES
    • Marketing Services
    • Reprints
    • Market Research
    • List Rental
    • Survey/Respondent Access
  • STAY CONNECTED
    • LinkedIn
    • Facebook
    • Instagram
    • YouTube
    • X (Twitter)
  • PRIVACY
    • PRIVACY POLICY
    • TERMS & CONDITIONS
    • DO NOT SELL MY PERSONAL INFORMATION
    • PRIVACY REQUEST
    • ACCESSIBILITY

Copyright ©2026. All Rights Reserved BNP Media, Inc. and BNP Media II, LLC.

Design, CMS, Hosting & Web Development :: ePublishing