ACHR News
search
Ask ACHR NEWS AI
cart
facebook twitter instagram linkedin youtube
  • Sign In
  • Subscribe
  • Sign Out
  • My Account
ACHR News
  • NEWS
    • Breaking News
    • New HVAC Products
    • Featured Products
    • Manufacturer Reports
    • HVAC Data
    • Legislation
    • ACHR NEWS Centennial
  • RESIDENTIAL
    • Air Conditioners
    • Furnaces
    • Residential Heat Pumps
    • Ductless
    • Residential IAQ
    • Testing, Monitoring, Tools
    • Components & Accessories
  • COMMERCIAL
    • Air Handlers
    • Rooftop Units
    • Chillers and Cooling Towers
    • Commercial Heat Pumps
    • Boilers and Hydronics
    • VRF/Ductless
    • Commercial IAQ
  • REFRIGERATION
    • Refrigerants
    • Refrigerant Regulations
    • Leak Management
  • CONTRACTOR PRO
    • Geothermal
    • Homeowner Study
    • VRF and VRV Ductless
    • Unitary Trends
  • EDUCATION
    • Training and Education
    • Business Management
    • Service and Maintenance
    • Continuing Education
    • Market Research >
      • HVAC Brand Awareness Report
      • VRV, VRF, VRVZ Report
      • Unitary Trends Report
      • Water Heat Professionals Report
    • Webinars
    • Sponsor Insights
    • eProducts Info
    • White Papers
  • EVENTS
    • HVAC Contractor Forum
    • Industry Events and Webinars
  • MEDIA
    • Videos
    • AHR Expo 2025 Videos
    • Podcasts >
      • ACHR News Podcast
      • HARDI Podcasts
      • AHR Expo Podcasts
      • ACCA Podcasts
    • Interactive Spotlights
    • Quizzes
    • eBooks
    • HVAC Talkback
  • HVAC GROUP
    • ACHR NEWS >
      • Current Issue
      • Digital Edition
      • Subscribe
    • Distribution Trends
    • SNIPS NEWS >
      • Join SNIPS NEWS
    • Engineered Systems News >
      • Join ES News
    • HVACR Directory
    • Contests
    • Newsletters
    • Contact
    • Advertise
    • My Account

Taking The Mystery Out Of R-410A

By Peter Powell
May 29, 2003
WINNIPEG, Manitoba — The single most talked about new refrigerant in the industry is R-410A. Perhaps the least understood refrigerant among contractors and technicians could well be R-410A. The refrigerant raising the most caution flags when it comes to higher pressure is R-410A.

These and other reasons caused the Winnipeg Chapter of the Refrigeration Service Engineers Society to offer a daylong seminar on the subject. Some aspects of the presentations were specific to Canada, but much applied to technicians everywhere. The seminar included the basics of refrigeration, as well as the unique aspects of R-410A.

Portions of the program drew upon material from the publication Universal R-410A Safety and Training from ESCO Press.

Mark Miller

The Environment

Mark Miller, executive director of the Manitoba Ozone Protection Industry Association, noted the furor over R-410A is because it is an HFC and therefore “not an ozone depletor,” and the fact that it is “a binary near-azeotrope,” meaning it has only two refrigerants in its blend and little temperature glide. One theme of the conference was the concept that binary is better than ternary (three-refrigerant blends) and the lower the glide, the better.

Like his counterparts in the environmental movement in the United States, Miller is passionate about the need to protect the ozone layer, with the phaseout of CFCs and HCFCs as an important part of that effort.

He said, “The ozone layer is currently at its most vulnerable state and will be for the next 15 years. Severe ozone depletion in the Arctic spring could become more frequent.” Reduction of ozone-depleting substances such as CFCs and HCFCs “may have a positive environmental impact in the future.”

He added, “Given full implementation of the Montreal Protocol by all countries, the ozone layer will recover by the middle of this century.”

The Basics

Botho Kramer, a retired instructor from Red River College in Winnipeg, led attendees through some of the fundamentals of refrigeration and air conditioning, with an emphasis on R-410A. He specifically looked at each component in the refrigeration cycle.

It was noted that manufacturers have redesigned compressors to work with R-410A. Part of the redesign is an increased wall thickness due to higher pressures.

It was also noted that a compressor designed for R-22 should never be used with R-410A. The R-410A compressors have internal pressure relief (IPR) settings that are different than those for R-22. For example, the IPR will open at a pressure of 375 to 450 psig for R-22 systems and a pressure of 550 to 625 psig for R-410A systems. Kramer noted that the suction and discharge pressures are 50 percent to 70 percent greater with R-410A than R-22, but the discharge temperature of R-410A is lower due to its higher vapor heat capacity.

Looking for quick answers on air conditioning, heating and refrigeration topics? Try Ask ACHR NEWS, our new smart AI search tool. Ask ACHR NEWS →

It was noted that R-410A will require a change in the high- and low-pressure switch settings due to increased pressure of the refrigerant.

As far as the condenser is concerned, it was noted that equipment designed for R-22 cannot withstand the higher pressure of R-410A. A condensing unit must be replaced with a specific model designed for R-410A.

Concerning filter-driers, Kramer said such components must have a rated working pressure of no less than 600 psig and must be approved for use with R-410A. And technicians need to check with system manufacturers for specific driers to use.

Kramer did note that liquid lines designed for R-22 can also be used with R-410A “if sized correctly and cleaned properly.”

A major issue concerned metering devices, with Kramer noting that if the same metering device was used in an R-410A system and an R-22 system, it would be oversized in the 410A system, because the higher pressures of 410A systems make for greater refrigerant mass flow rates through the metering device. Kramer said R-410A metering systems are designed to be about 15 percent smaller than those in R-22 systems in order to achieve the same capacity.

One question that arose concerned being able to use the evaporator or indoor coil from an R-22 system when changing out to a 410A air conditioner. It was noted that although some R-22 indoor coils meet the UL-approved design and service pressure rating of 235 psig, a technician should discuss the situation with the manufacturer before using an R-22 indoor coil with R-410A. And Kramer said suction lines used with R-22 can also be used with R-410A, provided they are properly sized and properly cleaned.

George Kurowski

The Chemistry

In looking at the chemistry of R-410A, George Kurowski, an instructor at Red River College, began his discussion by noting the widespread use of R-22 may have contributed to its phaseout. While HCFC-22 did not have near the ozone depleting potential of CFCs, it was so widely used that any leakage came from so many places and applications as to raise concern of environmentalists.

“R-22 was its own worst enemy,” he said.

Another issue for contractors to be aware of, he said, is the color of refrigerant containers. R-410A has rose color cylinders while

R-407C cylinders are said to be medium brown. “But I’m seeing variations in this color for 407C, with cylinders that may look tan.”

Much of his talk focused on temperature glides of HFC refrigerants and terminology such as azeotropic, near-azeotropic, and zeotrophic. He noted that R-410A is typically classified as a near-azeotropic. “But because R-410A has a very small temperature glide and fractionation potential, the blend is often referred to as an azeotropic blend. This is because it acts much like a single component or pure compound refrigerant.” By contrast, he said, R-407C has a high temperature glide. “The technician will have to use a pressure/temperature chart and note that there is both a dew point temperature and a bubble point temperature for each pressure value listed for 407C.”

One argument advanced for use of R-407C in place of R-22 is that is does not require a major equipment changeout as does R-410A. But because of issues like glide and efficiencies, Kurowski said, “If an R-22 system is in real trouble, the technician would prefer a total conversion to R-410A rather than a retrofit to 407C.”

He took a look at the tools for R-410A. He said the gauge manifold needs to be specially designed to withstand high pressures. Manifold sets for this application range up to 800 psig on the high side and 250 psig on the low side with a 550 psig low-side retard. Hoses need a service rating of 800 psig. Micron gauges need to be used when evacuating a system to 500 microns, as manifolds will not read the deeper vacuum measurements accurately.

On top of this, Kurowski noted that a 500-micron evacuation will not separate moisture from POE oils in R-410A systems. So, in addition to a 500-micron evacuation, a liquid line filter-drier must be installed and replaced whenever a system is opened.

He did speak favorably of tools, test instruments, and recovery equipment on the market today for use with R-410A. One piece of advice to technicians concerned adding R-410A to a system and making sure it comes out of the charging cylinder as a liquid to avoid any fractionation and for optimum system performance.

An additional consideration concerns the concept of ‘throttle.’ If a service tech wants to add liquid refrigerant to an operating system, it is important to make sure the liquid is throttled, and thus vaporized into the low side of the system to avoid compressor damage. A throttling valve can be used to ensure that liquid is converted to vapor prior to entering the system.

Kurowski’s enthusiasm for HFCs came in part from what he sees as a rapid movement away from R-22 by major manufacturers. He cautioned attendees not to assume supplies will be adequate by relying on secondary — and sometimes questionable — sources of R-22.

“I’m talking about smuggling. If you get involved with that situation, you can be seen as a bandit, a thief, a bad guy. And we don’t need that in our industry.”

Another motive, he said, for moving from HCFCs is what he perceived as pending Canadian legislation designed to crack down on improper practices working with CFCs and HCFCs. Kurowski claimed that in some provinces in Canada there are recertification requirements and legislation “that are enough to make one’s blood run cold.”

Ted Schulz

The Oil Issue

Ted Schulz, a technician from Trane Canada, called for “diligence on oil.” He noted polyolester oils (POEs) have become the oils of choice for such HFC refrigerants as R-410A, R-407C, and R-404A. The fact that they are wax-free “gives a lower pour point.” The caution flag goes up, he said, because they “are very hygroscopic,” meaning they will attract and retain moisture easily.

“POEs are big sponges,” he said. “There can never be enough concern about how to handle them.”

He then ticked off special concerns with POE such as:

  • Never store POE in a plastic container. Always use a glass or metal container. (He did note that “no one would carry a glass one in a truck.”)

  • Use a pump to transfer POE lubricants.

  • Use an approved POE lubricant, because lubricants are not always interchangeable.

  • POE can be irritating to skin, so use rubber gloves and safety glasses.

    Brian Baker

    The Safety Factor

    Brian Baker, a Winnipeg contractor and an RSES regional director, talked about safety, stressing the need to wear eye protection, to be aware of emergency exits, fire extinguishers, and first aid stations, and to keep work areas clean of debris and free of spilled liquids.

    Bill Grywinski, service manager of Trane Canada, reviewed classifications of refrigerants based on flammability and toxicity, noting that most of the refrigerants used throughout the industry have been determined to be nonflammable and nontoxic. He also took the technicians through procedures regarding the Material Safety Data Sheet.

    Publication date: 06/02/2003

  • Share This Story

    Looking for a reprint of this article?
    From high-res PDFs to custom plaques, order your copy today!

     

    Peter Powell is Refrigeration Editor. He can be contacted at 815-654-7270 or peterpowell@achrnews.com. Peter was formerly Editor/Publisher of Service & Contracting, where he gained his refrigeration experience. Among his duties, Powell is responsible for the monthly Refrigeration Zone sections in The NEWS

    Recommended Content

    JOIN TODAY
    To unlock your recommendations.

    Already have an account? Sign In

    • HVAC-enrollment

      The Trades Are Back: HVACR Programs See Nearly 30% Enrollment Spike

      A new wave of future technicians is entering the pipeline.  
      News
      By: Matt Jachman
    • 2025 Top 40 Under 40

      2025 Top 40 Under 40 HVACR Professionals List

      The 11th annual Top 40 Under 40 list highlights those...
      HVAC Commercial Market
      By: Hannah Belloli-Oster
    • LG Ductless Mini-Split Systems

      The 9 Types of Heat Pumps

      As the U.S. moves toward electrification, heat pumps are...
      Ground Source Heat Pumps
      By: Joanna R. Turpin
    Subscription Center
    • Create an Account
    • Start a Subscription
    • Manage My Account
    • Sign Up for Newsletters
    • Visit Customer Service
    • Update Preferences

    More Videos

    Sponsored Content

    Sponsored Content is a special paid section where industry companies provide high quality, objective, non-commercial content around topics of interest to The News audience. All Sponsored Content is supplied by the advertising company and any opinions expressed in this article are those of the author and not necessarily reflect the views of The News or its parent company, BNP Media. Interested in participating in our Sponsored Content section? Contact your local rep!

    close
    • Piggy Bank
      Sponsored byWatercress Financial

      Energy Prices, Inflation, and HVAC: What Today’s Homeowners Care About

    • Refrigerated Food
      Sponsored bySolstice Advanced Materials

      R-455A Refrigeration: A Cold Storage Solution for the Future

    • Airex Rooftop Units
      Sponsored byAirex Manufacturing Inc

      Consolidating Roof Penetrations: A Growing Trend in Multifamily HVAC Design

    Popular Stories

    HVAC-Price-Increase-graphic

    HVAC Price Increase List: June 2026

    Trump-Section-232.jpg

    Trump Reduces Section 232 Tariffs on HVAC Equipment to 15%

    R410A-Refrigerant-Cylinder.jpg

    Refrigerant Recovery is a Revenue Opportunity

    Heat-pump-cutaway.jpg

    PFAS Rules and A2L Building Codes Continue to Evolve

    Kroger.jpg

    Kroger to Spend $100 Million to Reduce Refrigerant Leaks

    View The ACHR NEWS
    Centennial Anniversary Timeline

    The ACHR News Timeline Chart
    Submit a Letter
    Submit a letter to our editors.

    Events

    November 6, 2025

    Next-Gen Data Center Cooling: HVAC Innovation and Real-World Solutions

    On Demand As AI workloads and high-density computing push traditional cooling methods to their limits, the data center industry is accelerating the adoption of next-generation HVAC technologies.

    June 9, 2026

    Before You Go All In on AI: Set Up Your Business to Actually Win

    In this webinar, we'll walk you through exactly what to get in place before you add AI to your business. You'll leave with a clear picture of where you stand today and a practical action plan to set yourself up for real results.

    View All Submit An Event

    Poll

    Summer Staff

    Are you fully staffed for the summer season?
    View Results Poll Archive

    Products

    BNI Mechanical/Electrical Square Foot Costbook, 2026 Edition

    BNI Mechanical/Electrical Square Foot Costbook, 2026 Edition

    See More Products
    A2L Refrigerants - Free Webinar - May 21, 2026

    Related Articles

    • Prime Time to Educate Consumers About the Benefits of R-410A

      See More
    • A Contractor’s View of R-410A

      See More
    • April 17, 2007: Three Chinese Manufacturers Meet Criteria of Honeywell R-410A Certified Program

      See More

    Related Products

    See More Products
    • ac.png

      Air Conditioning Service Guide R-410A and R-22 Systems 2nd Edition

    • Electrical Fundamentals for HVAC/R Technicians

    See More Products

    Events

    View AllSubmit An Event
    • May 21, 2026

      The A2L Genie is Out of the Refrigerant Canister – What Now?

      On Demand Join this webinar to learn about key updates to refrigerant regulations. We will cover practical installation and servicing content gathered from thousands of our interactions with contractors across the US and Canada.
    • October 14, 2012

      Taking Energy Solutions to the Next Level: Selling Efficiency Effectively

      MSCA LIVE 2012's optional program, Taking Energy Solutions to the Next Level: Selling Efficiency Effectively,will highlight the true value of improving energy efficiency.
    View AllSubmit An Event

    Related Directories

    • Solstice Advanced Materials Inc.

      Developer and manufacturer of LGWP HFO refrigerants. Solstice® N41, nonflammable and reduced GWP replacement for R-410A and Solstice® N40 for new supermarkets and R-404A retrofits.
    ×

    Sign Up. Stay Informed.

    The #1 trusted source for the HVACR industry since 1926

    SUBSCRIBE
    • RESOURCES
      • Advertise
      • Contact Us
      • Advisory Board
      • Classifieds
      • Submit a Letter
      • Directories
      • Store
    • ACCOUNT CENTER
      • Create an Account
      • Start a Subscription
      • Manage My Account
      • Sign Up for Newsletters
      • Visit Customer Service
      • Update Preferences
    • SERVICES
      • Marketing Services
      • Reprints
      • Market Research
      • List Rental
      • Survey/Respondent Access
    • STAY CONNECTED
      • LinkedIn
      • Facebook
      • Instagram
      • YouTube
      • X (Twitter)
    • PRIVACY
      • PRIVACY POLICY
      • TERMS & CONDITIONS
      • DO NOT SELL MY PERSONAL INFORMATION
      • PRIVACY REQUEST
      • ACCESSIBILITY

    Copyright ©2026. All Rights Reserved BNP Media, Inc. and BNP Media II, LLC.

    Design, CMS, Hosting & Web Development :: ePublishing