ACHR News
search
Ask ACHR NEWS AI
cart
facebook twitter instagram linkedin youtube
  • Sign In
  • Subscribe
  • Sign Out
  • My Account
ACHR News
  • NEWS
    • Breaking News
    • New HVAC Products
    • Featured Products
    • Manufacturer Reports
    • HVAC Data
    • Legislation
    • ACHR NEWS Centennial
  • RESIDENTIAL
    • Air Conditioners
    • Furnaces
    • Residential Heat Pumps
    • Ductless
    • Residential IAQ
    • Testing, Monitoring, Tools
    • Components & Accessories
  • COMMERCIAL
    • Air Handlers
    • Rooftop Units
    • Chillers and Cooling Towers
    • Commercial Heat Pumps
    • Boilers and Hydronics
    • VRF/Ductless
    • Commercial IAQ
  • REFRIGERATION
    • Refrigerants
    • Refrigerant Regulations
    • Leak Management
  • CONTRACTOR PRO
    • Geothermal
    • Homeowner Study
    • VRF and VRV Ductless
    • Unitary Trends
  • EDUCATION
    • Training and Education
    • Business Management
    • Service and Maintenance
    • Continuing Education
    • Market Research >
      • HVAC Brand Awareness Report
      • VRV, VRF, VRVZ Report
      • Unitary Trends Report
      • Water Heat Professionals Report
    • Webinars
    • Sponsor Insights
    • eProducts Info
    • White Papers
  • EVENTS
    • HVAC Contractor Forum
    • Industry Events and Webinars
  • MEDIA
    • Videos
    • AHR Expo 2025 Videos
    • Podcasts >
      • ACHR News Podcast
      • HARDI Podcasts
      • AHR Expo Podcasts
      • ACCA Podcasts
    • Interactive Spotlights
    • Quizzes
    • eBooks
    • HVAC Talkback
  • HVAC GROUP
    • ACHR NEWS >
      • Current Issue
      • Digital Edition
      • Subscribe
    • Distribution Trends
    • SNIPS NEWS >
      • Join SNIPS NEWS
    • Engineered Systems News >
      • Join ES News
    • HVACR Directory
    • Contests
    • Newsletters
    • Contact
    • Advertise
    • My Account

Seven Tips For Servicing Ice Machines

October 31, 2001
Repairing commercial ice machines can be a tedious experience for some service techs. However, following these seven tips can make troubleshooting less difficult and less time consuming. 1. Recall the particular machine’s operating sequence in order to see what function is not being performed. It is important to have a wiring diagram handy to help you trace the electrical system if necessary. Wiring diagrams may be obtained from the ice machine’s manufacturer.

2. Before making any adjustments or repairs, ask the customer to describe the problem; then inspect the entire machine for any obvious defects. Look at the entire picture:

  • Where is the machine installed? Is it boxed in without sufficient ventilation? This is especially important regarding machines with air-cooled condensers; most manufacturers recommend at least a 6-in. clearance on all sides of the machine.
  • Is the proper voltage being supplied to the machine?
  • Is the ambient temperature too high or too low? Most ice machines should be installed in a room with temperatures ranging from 55¿ to 95¿F.
  • Is water supplied to the machine, and does an adequate supply exist? On most machines, a 3/8-in. water line is sufficient for proper supply.
  • 3. If you don’t see any visual defects, check the machine’s major components.

  • Does the water pump operate? Is the water flowing properly over the evaporator? You can easily check this by turning the selector switch to the wash position and observing the water flow.
  • If the water pump runs but does not pump, check for any restrictions or air pockets in the distribution system. If there are none, the pump may need to be replaced.
  • If the pump does not run, make sure the proper voltage is being supplied. If you can’t measure any voltage, trace the electrical system to find out why.
  • Is any water flowing into the bin, or down the overflow or dump drains? Water loss is often the result of an improperly adjusted inlet water float valve. Check the manufacturer’s specifications and readjust the valve accordingly. Also, make sure the ice machine is level; a machine that is not level may dump its water into the bin or down the drain.
  • 4. If you don’t find any problems in the water distribution system, examine the refrigeration system. Install both a suction and discharge gauge, and observe both pressures during the entire freeze and defrost cycles. The discharge pressure should be within the manufacturer’s specifications. A higher-than-normal discharge pressure can be caused by one of several problems, including but not limited to:

  • The presence of a noncondensable in the system;
  • A dirty condenser (air-cooled models only);
  • Improper airflow through the condenser (air-cooled models only);
  • Lack of water flow to the condenser (water-cooled models only); or
  • A misadjusted or defective water-regulating valve (water-cooled models only).
  • A lower-than-normal discharge pressure is usually caused by a low refrigerant charge; check the system for leaks. If you find one, repair it and recharge the system.

    5. Observe the machine’s suction pressure, and even initiate the end of the freeze cycle by monitoring the suction with a low-pressure control. At the start of the cycle, the suction pressure will start out high and gradually pull down. Consult with the manufacturer regarding the proper pressure (values vary slightly with each machine). A higher-than-normal pressure may be a sign of an inefficient compressor, leaking hot gas solenoid valve, or overcharge of refrigerant. Lower-than-normal initial suction pressure can be caused by a low refrigerant charge, restricted system, or defective thermostatic expansion valve. As the water freezes and the evaporator temperature drops, the suction pressure will pull down and reach its final value just before the machine goes into the defrost cycle. If the machine goes into the cycle before reaching this final value, the ice cube slab may be too small and may fail to meet the manufacturer’s specifications. In this case, adjust the cube-size control and let the machine run longer in the freeze cycle. If the suction pressure drops below its designated value, the slab may be too large and difficult to separate from the evaporator plate during the defrost cycle. Most machines should be adjusted to form a 1/8-in. bridge on the slab, which allows the cubes to separate from the evaporator in one piece and then break apart easily as the slab drops into the bin.

    6. If both the water distribution system and freeze cycle operate normally, check the defrost cycle. Hot gas from the refrigeration system discharge should bypass the condenser and thermostatic expansion valve and enter the evaporator. This warms the ice slab, allowing it to separate from the evaporator and drop into the bin. The water pump should also shut down to prevent the ice from becoming wet and the water from dumping into the bin. Suction pressure will rise during this cycle and should be monitored to make sure it stays within the manufacturer’s limits. If the pressure goes beyond the limits, the compressor could overheat and possibly damage the windings. If it is too low or does not change over from the freeze cycle, the slab may be unable to separate and fall into the bin. This can result from a defective hot gas solenoid valve (doesn’t open) or a defective cube-size control (doesn’t switch the machine into the defrost cycle).

    7. After any repairs or adjustments are made, watch and time at least one complete cycle. Observe at least two cycles on any new installation. This ensures that the machine functions according to the manufacturer’s specifications, and that any adjustments or repairs were done correctly. Above all, ice machines should be cleaned regularly for continued proper operation, and the manufacturer’s cleaning procedures should be followed exactly.

    Marchese is owner of Arctic-Air Refrigeration, Pittsburgh, PA. He can be reached at P.O. Box 97022, Pittsburgh, PA 15229; 412-734-4433.

    Publication date: 11/05/2001

    Looking for quick answers on air conditioning, heating and refrigeration topics? Try Ask ACHR NEWS, our new smart AI search tool. Ask ACHR NEWS →

    Share This Story

    Looking for a reprint of this article?
    From high-res PDFs to custom plaques, order your copy today!

     

    Recommended Content

    JOIN TODAY
    To unlock your recommendations.

    Already have an account? Sign In

    • HVAC-enrollment

      The Trades Are Back: HVACR Programs See Nearly 30% Enrollment Spike

      A new wave of future technicians is entering the pipeline.  
      Training and Education
      By: Matt Jachman
    • 2025 Top 40 Under 40

      2025 Top 40 Under 40 HVACR Professionals List

      The 11th annual Top 40 Under 40 list highlights those...
      HVAC Contracting
      By: Hannah Belloli-Oster
    • LG Ductless Mini-Split Systems

      The 9 Types of Heat Pumps

      As the U.S. moves toward electrification, heat pumps are...
      Ground Source Heat Pumps
      By: Joanna R. Turpin
    Subscription Center
    • Create an Account
    • Start a Subscription
    • Manage My Account
    • Sign Up for Newsletters
    • Visit Customer Service
    • Update Preferences

    More Videos

    Sponsored Content

    Sponsored Content is a special paid section where industry companies provide high quality, objective, non-commercial content around topics of interest to The News audience. All Sponsored Content is supplied by the advertising company and any opinions expressed in this article are those of the author and not necessarily reflect the views of The News or its parent company, BNP Media. Interested in participating in our Sponsored Content section? Contact your local rep!

    close
    • Piggy Bank
      Sponsored byWatercress Financial

      Energy Prices, Inflation, and HVAC: What Today’s Homeowners Care About

    • Refrigerated Food
      Sponsored bySolstice Advanced Materials

      R-455A Refrigeration: A Cold Storage Solution for the Future

    • Airex Rooftop Units
      Sponsored byAirex Manufacturing Inc

      Consolidating Roof Penetrations: A Growing Trend in Multifamily HVAC Design

    Popular Stories

    Outdoor-condensing-units.jpg

    EPA Removes R-410A Installation Deadline

    Trump-Section-232.jpg

    Trump Reduces Section 232 Tariffs on HVAC Equipment to 15%

    cooling-habits.jpg

    50 Percent of Americans Have Skipped HVAC Maintenance

    ACHR NEWS Editor Chris Gray Presenting HVAC Minute 5-18-2026

    HVAC Manufacturers Fight Pricing Lawsuits

    tim-brooks.jpeg

    2026’s Best Distributor Partners With Customers

    View The ACHR NEWS
    Centennial Anniversary Timeline

    The ACHR News Timeline Chart
    Submit a Letter
    Submit a letter to our editors.

    Events

    November 6, 2025

    Next-Gen Data Center Cooling: HVAC Innovation and Real-World Solutions

    On Demand As AI workloads and high-density computing push traditional cooling methods to their limits, the data center industry is accelerating the adoption of next-generation HVAC technologies.

    June 9, 2026

    Before You Go All In on AI: Set Up Your Business to Actually Win

    In this webinar, we'll walk you through exactly what to get in place before you add AI to your business. You'll leave with a clear picture of where you stand today and a practical action plan to set yourself up for real results.

    View All Submit An Event

    Poll

    EPA Decision

    Are you happy the EPA decided contractors can continue to install R-410A equipment?
    View Results Poll Archive

    Products

    BNI Mechanical/Electrical Square Foot Costbook, 2026 Edition

    BNI Mechanical/Electrical Square Foot Costbook, 2026 Edition

    See More Products
    A2L Refrigerants - Free Webinar - May 21, 2026

    Related Articles

    • Seven Tips for a Healthy Computer

      See More
    • Installing Variable Refrigerant Flow on a Roof - The ACHR News

      Seven Tips for Installing Variable Refrigerant Flow on a Roof

      See More
    • QuickPurge® range

      Seven Tips for Inert Gas Weld Purging of Pipes

      See More

    Related Products

    See More Products
    • Troubleshooting Tips for Servicing Refrigeration Systems

    • Green Tips for Building Maintenance Engineers

    • Lessons Learned Servicing Boilers

    See More Products

    Related Directories

    • Blueair Food Service Equipment LLC

      Blueair Food Service Equipment LLC- Purveyors of self-contained refrigeration and ice machines. Reach ins, ice machines, sandwich prep tables, merchandisers, back bar equipment, etc.
    ×

    Sign Up. Stay Informed.

    The #1 trusted source for the HVACR industry since 1926

    SUBSCRIBE
    • RESOURCES
      • Advertise
      • Contact Us
      • Advisory Board
      • Classifieds
      • Submit a Letter
      • Directories
      • Store
    • ACCOUNT CENTER
      • Create an Account
      • Start a Subscription
      • Manage My Account
      • Sign Up for Newsletters
      • Visit Customer Service
      • Update Preferences
    • SERVICES
      • Marketing Services
      • Reprints
      • Market Research
      • List Rental
      • Survey/Respondent Access
    • STAY CONNECTED
      • LinkedIn
      • Facebook
      • Instagram
      • YouTube
      • X (Twitter)
    • PRIVACY
      • PRIVACY POLICY
      • TERMS & CONDITIONS
      • DO NOT SELL MY PERSONAL INFORMATION
      • PRIVACY REQUEST
      • ACCESSIBILITY

    Copyright ©2026. All Rights Reserved BNP Media, Inc. and BNP Media II, LLC.

    Design, CMS, Hosting & Web Development :: ePublishing