ACHR News
search
Ask ACHR NEWS AI
cart
facebook twitter instagram linkedin youtube
  • Sign In
  • Subscribe
  • Sign Out
  • My Account
ACHR News
  • NEWS
    • Breaking News
    • New HVAC Products
    • Featured Products
    • Manufacturer Reports
    • HVAC Data
    • Legislation
    • ACHR NEWS Centennial
  • RESIDENTIAL
    • Air Conditioners
    • Furnaces
    • Residential Heat Pumps
    • Ductless
    • Residential IAQ
    • Testing, Monitoring, Tools
    • Components & Accessories
  • COMMERCIAL
    • Air Handlers
    • Rooftop Units
    • Chillers and Cooling Towers
    • Commercial Heat Pumps
    • Boilers and Hydronics
    • VRF/Ductless
    • Commercial IAQ
  • REFRIGERATION
    • Refrigerants
    • Refrigerant Regulations
    • Leak Management
  • CONTRACTOR PRO
    • Geothermal
    • Homeowner Study
    • VRF and VRV Ductless
    • Unitary Trends
  • EDUCATION
    • Training and Education
    • Business Management
    • Service and Maintenance
    • Continuing Education
    • Market Research >
      • HVAC Brand Awareness Report
      • VRV, VRF, VRVZ Report
      • Unitary Trends Report
      • Water Heat Professionals Report
    • Webinars
    • Sponsor Insights
    • eProducts Info
    • White Papers
  • EVENTS
    • HVAC Contractor Forum
    • Industry Events and Webinars
  • MEDIA
    • Videos
    • AHR Expo 2025 Videos
    • Podcasts >
      • ACHR News Podcast
      • HARDI Podcasts
      • AHR Expo Podcasts
      • ACCA Podcasts
    • Interactive Spotlights
    • Quizzes
    • eBooks
    • HVAC Talkback
  • HVAC GROUP
    • ACHR NEWS >
      • Current Issue
      • Digital Edition
      • Subscribe
    • Distribution Trends
    • SNIPS NEWS >
      • Join SNIPS NEWS
    • Engineered Systems News >
      • Join ES News
    • HVACR Directory
    • Contests
    • Newsletters
    • Contact
    • Advertise
    • My Account
HVAC ContractingService and Maintenance

Btu Buddy 113: Restriction in the Liquid Line Problem

By Bill Johnson
August 20, 2012
Bob is a service technician who is well trained and nationally certified. However, he has sometimes suffered from the same confusion that all technicians occasionally do — the facts that he gathers may or may not point to the obvious cause of the problem or the best solution. But Bob has had something that no one else has. He recalled his long-time HVACR mentor and imagines him accompanying him as “Btu Buddy,” someone who reminded him to take time to stop and think before rushing to judgment, helping keep him on the right track, even with facts that are confusing.

Now, Bob’s company has promoted him to help train a new employee, right out of a school specializing in HVAC, just like Bob was. Bob is now Tim’s Btu Buddy. Tim is anxious to travel with Bob. Tim realizes that he is right out of school, with the theory and lab work that he accomplished in school, but still needs help. He knows that he worked with many of the components of the systems in the school, under ideal conditions with good light and air conditioning. Now it is into the field, sometimes under the house with poor lighting, or out on the rooftop in the sun, where the real action is. He is naturally and normally reluctant, but he has Bob to help guide him.

Bob and Tim have been sent on a call to a house with no cooling. The system has just been installed and the construction crew has been having problems with startup.

When they arrived, the construction foreman explained, “The unit began to freeze up shortly after startup so I put gauges on the unit. The suction pressure was very low, so I added refrigerant. The suction pressure only rose a little, and the head pressure went up quickly. I stopped adding refrigerant and called the office.”

Bob and Tim took it from there. Bob said, “The system has a capillary tube metering device. Let’s look at what may be wrong. Start the unit and let it run for 10 minutes while we look over the system.”

After about 10 minutes, Bob said to Tim, “Write these numbers down. We know that:

1. The refrigerant is R-410A.

2. The return air temperature is 85°F because the inside of the house is hot and the unit has not been running.

3. The outside ambient is 95°.

Looking for quick answers on air conditioning, heating and refrigeration topics? Try Ask ACHR NEWS, our new smart AI search tool. Ask ACHR NEWS →

4. The metering device is a capillary tube.

5. The suction pressure is 75 psig, corresponding to 18°.

6. The head pressure is 506 psig, corresponding to 135°.

7. The head pressure should be about 445.8 psig, corresponding to 125° (95° + 30° = 125°).”

Bob asked Tim, “What do you see in these numbers?”

Tim said, “It is just like the construction foreman said, there is plenty of load on the unit and it is still freezing up. He added refrigerant and something is not right because the suction pressure is still well below freezing and the head pressure is too high. I think that now it has too much refrigerant in the system.”

Bob asked, “What do you think we should do next?”

Tim said, “You are asking me some hard questions, but I think there must be a restriction somewhere. How do we find it?”

Bob said, “Let’s do a touch test of the liquid line and see what we can find.”

capillary tube connected to a strainer-drier
Figure 1. This is a one circuit example of a capillary tube connected to a strainer-drier. (From Refrigeration & Air Conditioning Technology, seventh edition, by William Whitman, William Johnson, John Tomczyk, and Eugene Silberstein, published by Delmar Cengage Learning.) (©Delmar Cengage Learning.)

They started at the condensing unit and felt the liquid line all the way to the strainer-drier just before the capillary tubes. All seemed normal.

Bob said, “I believe the restriction is either in the strainer-drier or in the capillary tube system. Let’s recover the refrigerant and remove the strainer-drier. Then we can see if we can push nitrogen through it. If it seems as though it is not restricted, we will then remove the capillary tube system and change them both.”

Tim then asked, “Why not just remove the capillary tube system and the strainer-drier and change them both?”

Bob said, “There are actually four circuits which each have a capillary tube feeding it. If we can just change the strainer-drier, we will have a much easier repair. We will not have to deal with all of the silver brazing by removing the four circuits from the coil and then re-silver brazing them. At that point, I believe we would ask for a new coil and change it.”

They recovered the refrigerant and evacuated the system and raised the system pressure to 0 psig with nitrogen and removed the strainer-drier.

Bob said, “Take the nitrogen hose and nozzle and see how much nitrogen will blow through the strainer-drier. Use about 100 psig of pressure.”

Tim tried it and said, “Not very much is coming out.”

Bob then said, “Now try blowing it backwards. Put the hose in the outlet of the strainer-drier. Use this clean white handkerchief to see if you catch anything.”

Tim did it and said, “Wow, some trash came out and I caught it in the handkerchief. It seems as though more will flow now.”

Bob said, “You have found the problem. That is trash from when the unit was assembled at the factory. Use your cell phone and take a picture of the trash. Someone was careless. When we write the service report we will spell out what happened and include the photo. When our company bills the manufacturer for our time, they will be able to trace this problem right to the source in the factory. You have the evidence to show. Also, save the strainer-drier. They may also want to see it.”

They changed the strainer-drier, evacuated the system, and charged the unit with fresh refrigerant by weighing in the charge and started it up.

Tim looked at the gauges and said, “That was a really interesting set of circumstances. Things are different every day it seems like. I think I like that.”

Bob added, “In this business of troubleshooting, the education never ends. I like that because not just everybody will take the time to learn this business. That means that the opportunity and income keeps going up.”

Publication date: 8/20/2012

KEYWORDS: maintenance for HVACR metering devices troubleshooting and HVACR

Share This Story

Looking for a reprint of this article?
From high-res PDFs to custom plaques, order your copy today!

 

Active in the HVACR industry since the 1950s, Bill Johnson graduated in gas fuel technology and refrigeration from the Southern Technical Institute, a branch of Georgia Tech (now known as Southern Polytechnic Institute). He taught HVAC classes at Coosa Valley Vocational & Technical Institute for four years. He moved on to become service manager for Layne Trane, Charlotte, N.C. He taught for 15 years at Central Piedmont Community College, part of this time as program director. He had his own business for five years doing installation and service work. Now retired, he is the author of Practical Heating Technology and Practical Cooling Technology, and continues as a co-author of Refrigeration & Air Conditioning Technology, seventh edition, all published by Delmar Cengage Learning. For more information, he can be reached at 704-968-0000 or thebillj1@gmail.com.

Btu Buddy Notebook is a collection of more than 50 service call scenarios in book form covering both cooling season and heating season troubleshooting. For more information and to purchase the book, visit the HVACR Industry Store.

Recommended Content

JOIN TODAY
To unlock your recommendations.

Already have an account? Sign In

  • HVAC-enrollment

    The Trades Are Back: HVACR Programs See Nearly 30% Enrollment Spike

    A new wave of future technicians is entering the pipeline.  
    Training and Education
    By: Matt Jachman
  • 2025 Top 40 Under 40

    2025 Top 40 Under 40 HVACR Professionals List

    The 11th annual Top 40 Under 40 list highlights those...
    HVAC Residential Market
    By: Hannah Belloli-Oster
  • LG Ductless Mini-Split Systems

    The 9 Types of Heat Pumps

    As the U.S. moves toward electrification, heat pumps are...
    News
    By: Joanna R. Turpin
Subscription Center
  • Create an Account
  • Start a Subscription
  • Manage My Account
  • Sign Up for Newsletters
  • Visit Customer Service
  • Update Preferences

More Videos

Sponsored Content

Sponsored Content is a special paid section where industry companies provide high quality, objective, non-commercial content around topics of interest to The News audience. All Sponsored Content is supplied by the advertising company and any opinions expressed in this article are those of the author and not necessarily reflect the views of The News or its parent company, BNP Media. Interested in participating in our Sponsored Content section? Contact your local rep!

close
  • Piggy Bank
    Sponsored byWatercress Financial

    Energy Prices, Inflation, and HVAC: What Today’s Homeowners Care About

  • Refrigerated Food
    Sponsored bySolstice Advanced Materials

    R-455A Refrigeration: A Cold Storage Solution for the Future

  • Airex Rooftop Units
    Sponsored byAirex Manufacturing Inc

    Consolidating Roof Penetrations: A Growing Trend in Multifamily HVAC Design

Popular Stories

HVAC-Price-Increase-graphic

HVAC Price Increase List: June 2026

Trump-Section-232.jpg

Trump Reduces Section 232 Tariffs on HVAC Equipment to 15%

ACHR NEWS Editor Chris Gray Presenting HVAC Minute 5-18-2026

HVAC Manufacturers Fight Pricing Lawsuits

R410A-Refrigerant-Cylinder.jpg

Refrigerant Recovery is a Revenue Opportunity

Heat-pump-cutaway.jpg

PFAS Rules and A2L Building Codes Continue to Evolve

View The ACHR NEWS
Centennial Anniversary Timeline

The ACHR News Timeline Chart
Submit a Letter
Submit a letter to our editors.

Events

November 6, 2025

Next-Gen Data Center Cooling: HVAC Innovation and Real-World Solutions

On Demand As AI workloads and high-density computing push traditional cooling methods to their limits, the data center industry is accelerating the adoption of next-generation HVAC technologies.

June 9, 2026

Before You Go All In on AI: Set Up Your Business to Actually Win

In this webinar, we'll walk you through exactly what to get in place before you add AI to your business. You'll leave with a clear picture of where you stand today and a practical action plan to set yourself up for real results.

View All Submit An Event

Poll

Summer Staff

Are you fully staffed for the summer season?
View Results Poll Archive

Products

BNI Mechanical/Electrical Square Foot Costbook, 2026 Edition

BNI Mechanical/Electrical Square Foot Costbook, 2026 Edition

See More Products
A2L Refrigerants - Free Webinar - May 21, 2026

Related Articles

  • Btu Buddy 137: Heat Pump Problem in the Summer

    See More
  • cooling a hot compressor

    Btu Buddy 163: Suction Line Restriction

    See More
  • Btu Buddy 80: Duct Restriction

    See More
×

Sign Up. Stay Informed.

The #1 trusted source for the HVACR industry since 1926

SUBSCRIBE
  • RESOURCES
    • Advertise
    • Contact Us
    • Advisory Board
    • Classifieds
    • Submit a Letter
    • Directories
    • Store
  • ACCOUNT CENTER
    • Create an Account
    • Start a Subscription
    • Manage My Account
    • Sign Up for Newsletters
    • Visit Customer Service
    • Update Preferences
  • SERVICES
    • Marketing Services
    • Reprints
    • Market Research
    • List Rental
    • Survey/Respondent Access
  • STAY CONNECTED
    • LinkedIn
    • Facebook
    • Instagram
    • YouTube
    • X (Twitter)
  • PRIVACY
    • PRIVACY POLICY
    • TERMS & CONDITIONS
    • DO NOT SELL MY PERSONAL INFORMATION
    • PRIVACY REQUEST
    • ACCESSIBILITY

Copyright ©2026. All Rights Reserved BNP Media, Inc. and BNP Media II, LLC.

Design, CMS, Hosting & Web Development :: ePublishing