ACHR News
search
Ask ACHR NEWS AI
cart
facebook twitter instagram linkedin youtube
  • Sign In
  • Subscribe
  • Sign Out
  • My Account
ACHR News
  • NEWS
    • Breaking News
    • New HVAC Products
    • Featured Products
    • Manufacturer Reports
    • HVAC Data
    • Legislation
    • ACHR NEWS Centennial
  • RESIDENTIAL
    • Air Conditioners
    • Furnaces
    • Residential Heat Pumps
    • Ductless
    • Residential IAQ
    • Testing, Monitoring, Tools
    • Components & Accessories
  • COMMERCIAL
    • Air Handlers
    • Rooftop Units
    • Chillers and Cooling Towers
    • Commercial Heat Pumps
    • Boilers and Hydronics
    • VRF/Ductless
    • Commercial IAQ
  • REFRIGERATION
    • Refrigerants
    • Refrigerant Regulations
    • Leak Management
  • CONTRACTOR PRO
    • Geothermal
    • Homeowner Study
    • VRF and VRV Ductless
    • Unitary Trends
  • EDUCATION
    • Training and Education
    • Business Management
    • Service and Maintenance
    • Continuing Education
    • Market Research >
      • HVAC Brand Awareness Report
      • VRV, VRF, VRVZ Report
      • Unitary Trends Report
      • Water Heat Professionals Report
    • Webinars
    • Sponsor Insights
    • eProducts Info
    • White Papers
  • EVENTS
    • HVAC Contractor Forum
    • Industry Events and Webinars
  • MEDIA
    • Videos
    • AHR Expo 2025 Videos
    • Podcasts >
      • ACHR News Podcast
      • HARDI Podcasts
      • AHR Expo Podcasts
      • ACCA Podcasts
    • Interactive Spotlights
    • Quizzes
    • eBooks
    • HVAC Talkback
  • HVAC GROUP
    • ACHR NEWS >
      • Current Issue
      • Digital Edition
      • Subscribe
    • Distribution Trends
    • SNIPS NEWS >
      • Join SNIPS NEWS
    • Engineered Systems News >
      • Join ES News
    • HVACR Directory
    • Contests
    • Newsletters
    • Contact
    • Advertise
    • My Account

Ice Breaker: System Charging for Flooded Condensers

By Joe Marchese
November 1, 2010

Refrigeration systems utilizing an outdoor air-cooled condenser located in an area where the outdoor temperature can drop below approximately 70°F must be designed to prevent the system’s discharge pressure from dropping too low. There are several different industry methods that can be used to successfully accomplish this task. The condenser fan motor(s) can be cycled on and off or its speed varied in response to a change in the system’s high side pressure. Another method (though not used very often) is to reduce the airflow across a condenser with some type of damper arrangement.

A popular method used by many designers is to flood the condenser with refrigerant during low ambient temperatures. This approach reduces the effective area of the condenser which in turn causes the discharge pressure to rise. A head pressure control valve installed on the outlet of the condenser restricts the refrigerant flow as the outdoor temperature drops. The refrigerant will begin to back up in the condenser causing it to become flooded with refrigerant.

In order for this valve to properly maintain a minimum high-side pressure, additional refrigerant needs to be added to the system to allow the condenser to become flooded. The system actually requires more refrigerant during low ambient temperatures than during peak load conditions at high outdoor ambient temperatures. The amount of additional refrigerant which must be added to the system is basically a factor of the size of the condenser and the lowest anticipated operating ambient temperature. To determine the additional amount of refrigerant that needs to be added, always refer to the system manufacturer’s guidelines.

TABLE IT

If these guidelines are not available, the head pressure control valve manufacturer may also have a recommended procedure. One suggested method is to first properly charge the system using normal industry methods. Then, weigh in the amount of additional refrigerant required to adequately flood the condenser. To determine the amount of additional refrigerant required, you must first determine the amount of refrigerant required to completely flood the condenser. This is done by using a table supplied by the valve manufacturer. To use this table you will need to record the following information:

• The diameter of the condenser tubing;

• Its total length (including the return bends of the condenser);

• Type of refrigerant used; and

• The lowest ambient conditions to be encountered.

For example, suppose a system utilizing an air-cooled condenser with a total length of 128 feet of 3/8-inch tubing needs to operate properly at an outdoor temperature of 0°F. If the system is using HFC-134a, then using the valve manufacturer’s table you determine the density factor per foot of tubing to be 0.054. This means for each foot of condenser tubing, you need to add 0.054 pounds of additional refrigerant. In this example, you have 128 feet of equivalent tubing, so 6.91 pounds of additional refrigerant needs to be added to completely flood the condenser (128 feet × 0.054 pounds/foot = 6.91 pounds).

However, completely flooding a condenser to achieve proper head control is not necessary. Another table is then used to adjust this value to determine the actual amount of additional refrigerant required to adequately maintain the system’s high-side pressure during the lowest anticipated outdoor temperature.

For example, if our system is operating at a 20° evaporating temperature, using another table you will find the original value of 6.91 pounds needs to be reduced by a factor of 78 percent, so you only really need to add 5.39 pounds (6.91 lbs × 0.78 = 5.39 lbs) of refrigerant to adequately flood the condenser at an outdoor temperature of 0°.

FACTORING IT ALL IN

There is one other concern using this method: You must also factor the current outdoor temperature when originally charging the system. If the outdoor air temperature is already below approximately 70°, the condenser will be partially flooded when charged using standard industry procedures. The weigh-in charge must again be adjusted to compensate for the already partially flooded condenser. To do this, you take the difference between the factor used for the lowest anticipated outdoor temperature and the current outdoor temperature.

For example, suppose the current outdoor temperature is 40°, and at this temperature the chart shows you to reduce the completely flooded charge by a factor of 60 percent.  You must use the difference between the factor of 78 percent (at 0°) and 60 percent (at 40°), so you now use a multiplication factor of only 18 percent (78 percent – 60 percent = 18 percent). That means you now multiply the original 6.91 pounds (completely flooded charge) by 18 percent, which means you now only add 1.24 pounds of additional refrigerant to the system.

Publication date: 11/01/2010

Share This Story

Looking for a reprint of this article?
From high-res PDFs to custom plaques, order your copy today!

 

Joe marchese

Joe Marchese is an author, instructor and HVACR service contractor. He can be reached at joe@koldcraft.com.

Recommended Content

JOIN TODAY
To unlock your recommendations.

Already have an account? Sign In

  • HVAC-enrollment

    The Trades Are Back: HVACR Programs See Nearly 30% Enrollment Spike

    A new wave of future technicians is entering the pipeline.  
    News
    By: Matt Jachman
  • 2025 Top 40 Under 40

    2025 Top 40 Under 40 HVACR Professionals List

    The 11th annual Top 40 Under 40 list highlights those...
    HVAC Commercial Market
    By: Hannah Belloli-Oster
  • LG Ductless Mini-Split Systems

    The 9 Types of Heat Pumps

    As the U.S. moves toward electrification, heat pumps are...
    News
    By: Joanna R. Turpin
Subscription Center
  • Create an Account
  • Start a Subscription
  • Manage My Account
  • Sign Up for Newsletters
  • Visit Customer Service
  • Update Preferences

More Videos

Sponsored Content

Sponsored Content is a special paid section where industry companies provide high quality, objective, non-commercial content around topics of interest to The News audience. All Sponsored Content is supplied by the advertising company and any opinions expressed in this article are those of the author and not necessarily reflect the views of The News or its parent company, BNP Media. Interested in participating in our Sponsored Content section? Contact your local rep!

close
  • Piggy Bank
    Sponsored byWatercress Financial

    Energy Prices, Inflation, and HVAC: What Today’s Homeowners Care About

  • Refrigerated Food
    Sponsored bySolstice Advanced Materials

    R-455A Refrigeration: A Cold Storage Solution for the Future

  • Airex Rooftop Units
    Sponsored byAirex Manufacturing Inc

    Consolidating Roof Penetrations: A Growing Trend in Multifamily HVAC Design

Popular Stories

HVAC-Price-Increase-graphic

HVAC Price Increase List: June 2026

Trump-Section-232.jpg

Trump Reduces Section 232 Tariffs on HVAC Equipment to 15%

Refrigerants-and-gauge.jpg

HVAC Industry Warns of Counterfeit Refrigerants Entering U.S. Supply Chain

Midea-training.jpg

HVAC Workforce Crisis Expands Beyond Technicians to Instructor Shortages

U.S. Supreme Court building

95% Furnace Efficiency Rule to Get New Hearing

View The ACHR NEWS
Centennial Anniversary Timeline

The ACHR News Timeline Chart
Submit a Letter
Submit a letter to our editors.

Events

November 6, 2025

Next-Gen Data Center Cooling: HVAC Innovation and Real-World Solutions

On Demand As AI workloads and high-density computing push traditional cooling methods to their limits, the data center industry is accelerating the adoption of next-generation HVAC technologies.

June 17, 2026

Decarbonization Without Disruption

This webinar will explore practical HVAC decarbonization strategies that minimize disruption while maximizing long-term performance and ROI.

View All Submit An Event

Poll

Summer Staff

Are you fully staffed for the summer season?
View Results Poll Archive

Products

BNI Mechanical/Electrical Square Foot Costbook, 2026 Edition

BNI Mechanical/Electrical Square Foot Costbook, 2026 Edition

See More Products
Decarbonization Without Disruption - Free Webinar - 6/17/2026

Related Articles

  • Ice Breaker: Refrigerant Numbering System Explained

    See More
  • Joe Marchese

    Ice Breaker: The Essence of a System Startup

    See More
  • Ice Breaker: Suction Line Pressure and System Capacity

    See More

Related Products

See More Products
  • Manual LLH Cover_Final.jpg

    Manual LLH - 2019 (HVAC System Design for Low Load Homes)

  • Troubleshooting Tips for Servicing Refrigeration Systems

  • Uncomplicating The Heat Pump: Electrical System Troubleshooting DVD

See More Products
×

Sign Up. Stay Informed.

The #1 trusted source for the HVACR industry since 1926

SUBSCRIBE
  • RESOURCES
    • Advertise
    • Contact Us
    • Advisory Board
    • Classifieds
    • Submit a Letter
    • Directories
    • Store
  • ACCOUNT CENTER
    • Create an Account
    • Start a Subscription
    • Manage My Account
    • Sign Up for Newsletters
    • Visit Customer Service
    • Update Preferences
  • SERVICES
    • Marketing Services
    • Reprints
    • Market Research
    • List Rental
    • Survey/Respondent Access
  • STAY CONNECTED
    • LinkedIn
    • Facebook
    • Instagram
    • YouTube
    • X (Twitter)
  • PRIVACY
    • PRIVACY POLICY
    • TERMS & CONDITIONS
    • DO NOT SELL MY PERSONAL INFORMATION
    • PRIVACY REQUEST
    • ACCESSIBILITY

Copyright ©2026. All Rights Reserved BNP Media, Inc. and BNP Media II, LLC.

Design, CMS, Hosting & Web Development :: ePublishing