ACHR News
search
Ask ACHR NEWS AI
cart
facebook twitter instagram linkedin youtube
  • Sign In
  • Subscribe
  • Sign Out
  • My Account
ACHR News
  • NEWS
    • Breaking News
    • New HVAC Products
    • Featured Products
    • Manufacturer Reports
    • HVAC Data
    • Legislation
    • ACHR NEWS Centennial
  • RESIDENTIAL
    • Air Conditioners
    • Furnaces
    • Residential Heat Pumps
    • Ductless
    • Residential IAQ
    • Testing, Monitoring, Tools
    • Components & Accessories
  • COMMERCIAL
    • Air Handlers
    • Rooftop Units
    • Chillers and Cooling Towers
    • Commercial Heat Pumps
    • Boilers and Hydronics
    • VRF/Ductless
    • Commercial IAQ
  • REFRIGERATION
    • Refrigerants
    • Refrigerant Regulations
    • Leak Management
  • CONTRACTOR PRO
    • Geothermal
    • Homeowner Study
    • VRF and VRV Ductless
    • Unitary Trends
  • EDUCATION
    • Training and Education
    • Business Management
    • Service and Maintenance
    • Continuing Education
    • Market Research >
      • HVAC Brand Awareness Report
      • VRV, VRF, VRVZ Report
      • Unitary Trends Report
      • Water Heat Professionals Report
    • Webinars
    • Sponsor Insights
    • eProducts Info
    • White Papers
  • EVENTS
    • HVAC Contractor Forum
    • Industry Events and Webinars
  • MEDIA
    • Videos
    • AHR Expo 2025 Videos
    • Podcasts >
      • ACHR News Podcast
      • HARDI Podcasts
      • AHR Expo Podcasts
      • ACCA Podcasts
    • Interactive Spotlights
    • Quizzes
    • eBooks
    • HVAC Talkback
  • HVAC GROUP
    • ACHR NEWS >
      • Current Issue
      • Digital Edition
      • Subscribe
    • Distribution Trends
    • SNIPS NEWS >
      • Join SNIPS NEWS
    • Engineered Systems News >
      • Join ES News
    • HVACR Directory
    • Contests
    • Newsletters
    • Contact
    • Advertise
    • My Account

The Hotline: 07/05/2004

July 2, 2004

Moisture Detection

QUESTION:
By Loy Lobo
Via E-mail

Is there a device that will detect moisture in a refrigeration system, which would act as a relay to trip off the system if the moisture level rose above a specific set value?

As refrigeration systems get older, the heat exchangers are prone to leak in the tubes or at tube sheets, especially when the water quality is not maintained. In this scenario, if a device was installed to detect this moisture, it could trip off the system, thus raising an alarm indicating that the system needs to be checked, which would save further damage to the system.

ANSWER:
From Dan Kramer, P.E.
Specialist Grade Member of RSES

There is a panel-mount dewpoint monitor/alarm by Mitchell Instruments. I would note that the sensor is aluminum oxide and could have a short life span in a wet environment with CFC, HCFC, or HFC refrigerants, which would hydrolyze to strong acids. If you want more help, call Mitchell Instruments at 888-270-2690.

Superheat Settings

QUESTION:
From Bill Blackwell
Diboll, Texas

I have a couple of questions about superheat settings on thermostatic expansion valves and subcooling in condensers. I can't seem to find out if the superheat setting on the valve is the same for a residential unit (8 degrees to 12 degrees F) and a walk-in freezer. I recently had to work on a reach-in unit and the valve superheat was about 18 degrees. The heat load wasn't high and airflow was good. The system pressures were OK.

Does the superheat setting for a valve change when you go from residential to commercial cooling? What about from commercial to refrigeration and from refrigeration to ice machines? Or does 8 degrees to 12 degrees apply to all of these applications?

My subcooling question is similar. Does the 5 degrees to 15 degrees subcooling for residential applications apply to commercial refrigeration and ice machine condensing units? Are these ranges (8 degrees to 12 degrees, and 5 degrees to 15 degrees) die-hard rules, or can you be plus or minus 3 degrees to 4 degrees?

Looking for quick answers on air conditioning, heating and refrigeration topics? Try Ask ACHR NEWS, our new smart AI search tool. Ask ACHR NEWS →

ANSWER:
By Don McClanahan
Technical Engineer
Emerson Flow Controls
St. Louis

The proper superheat would change based on the particular evaporator temperature. Take a look at the following examples:

Air conditioning at 40 degrees should be 10 degrees superheat.

Refrigeration at 35 degrees should be 8 degrees superheat.

Freezer at 0 degrees should be 4 degrees superheat.

Blower Motor

QUESTION:
By Richard Hawkins
Via E-mail

A while ago I had a flood in my basement. I had it cleaned up, but now my blower motor is not working. It does put out heat, but not enough. The furnace does turn on, but also shuts off after a minute or two. It does put out heat upstairs, but not downstairs.

ANSWER:
From Dave Anderlik
Consultant

It is not unusual for a furnace blower motor to fail due to a flooded basement. With a failed blower motor, you are seeing your furnace cycling on the high-limit control. This control is to prevent damage to your furnace from overheating and protect your property. The furnace blower motor needs to be replaced as soon as possible and the furnace should not be used until it is replaced. The reason you are getting some heat upstairs is because hot air is less dense (lighter), which causes it to rise.

I strongly encourage you not to use the furnace until the proper repair is made.

‘Dirty Sock' Syndrome

QUESTION:
From John Moorefield
Via E-Mail

I am looking for more information regarding the UVC solutions for the dreaded "Dirty Sock Syndrome." Specifically, how much does this cost? Can our local service dealer install the unit? How long does the UVC solution last?

ANSWER:
By Dan Kramer P.E.
Specialist Grade Member of RSES

Dirty Sock Syndrome is a disgusting occurrence when it affects air conditioners. It is caused by the growth of molds on and around the evaporator. It frequently arises when the drain pan is badly pitched or when organic matter accumulates on or near the evaporator, sometimes because the air filter has been (temporarily?) removed to improve the cooling effect.

The way to cope with this syndrome is to get at both sides of the evaporator and the drain pan and drain. I would spray the entire surface with a cleaner/oxidizer such as Clorox's "Cleanup" cleanser with bleach.

I wear a nose mask and goggles when using this stuff. It's fierce. Then I would wash everything down with a bristle brush and a detergent (like dishwasher detergent) to be sure that all of the solid remnants of the mold and the dirt on which it has been growing have been removed. Then I would rinse everything thoroughly since some of these chemicals may attack aluminum and/or copper over periods of time. If there is any sign that water has been collecting in the drain pan, the pan pitch must be corrected and the drain cleaned and enlarged, if necessary.

While I agree that UV may prevent further occurrences, I would not try to correct an existing situation using UV only. I believe that manual cleaning is the only sure fix, maybe then followed by UV lamps.

Another option to consider is replacing the evaporator with a new one.

Do-It-Yourself Installation

QUESTION:
Name Withheld by Request

What does the law state about the do-it-yourselfer market and the installation of residential split systems? To be more specific: If a contractor sells an A coil, line set, and a condensing unit to a homeowner who wants to install his/her own central air system in his/her own home, is the contractor in violation of any EPA refrigerant-handling laws? Is the homeowner required to have EPA-approved certification for refrigerant handling or transportation?

ANSWER:
From Julius Banks
US EPA Global Programs Division
Stratospheric Protection Implementation Branch

EPA regulations are not specific to the DIY market but apply to any person who maintains, services, repairs, or disposes of any refrigeration or air conditioning equipment containing an ODS refrigerant, as well as those who purchase or sell an ODS refrigerant. This holds for the sale and installation of split systems.

The refrigerant sales restriction discussed in great detail at www.epa.gov/ozone/title6/608/sales/sales.html does not include the sale of split systems containing an ODS refrigerant. However, the installation of such systems is restricted to technicians certified under Section 608 of the Clean Air Act. So, a homeowner would not be able to legally install such a system unless the homeowner was properly certified.

Wholesalers (or in this case the contractor) may sell different components of precharged split systems at different times to uncertified individuals as long as the contractor has reason to believe that these will be assembled into new split systems. This does not sound like the case in the scenario outlined. It appears that the contractor has knowledge or reason to believe that a certified technician will not install the system.

I encourage readers to visit our Web page for information concerning EPA refrigerant regulations at www.epa.gov/ozone/title6/608/608fact.html.

Contact The Hotline
Do you have a technical question for the pros? Submit your Hotline question directly by visiting our Extra Edition page and clicking on The Hotline link in the left-hand column.

Publication date: 07/05/2004

Share This Story

Looking for a reprint of this article?
From high-res PDFs to custom plaques, order your copy today!

 

Recommended Content

JOIN TODAY
To unlock your recommendations.

Already have an account? Sign In

  • HVAC-enrollment

    The Trades Are Back: HVACR Programs See Nearly 30% Enrollment Spike

    A new wave of future technicians is entering the pipeline.  
    Training and Education
    By: Matt Jachman
  • 2025 Top 40 Under 40

    2025 Top 40 Under 40 HVACR Professionals List

    The 11th annual Top 40 Under 40 list highlights those...
    HVAC Commercial Market
    By: Hannah Belloli-Oster
  • LG Ductless Mini-Split Systems

    The 9 Types of Heat Pumps

    As the U.S. moves toward electrification, heat pumps are...
    Heat Pumps
    By: Joanna R. Turpin
Subscription Center
  • Create an Account
  • Start a Subscription
  • Manage My Account
  • Sign Up for Newsletters
  • Visit Customer Service
  • Update Preferences

More Videos

Sponsored Content

Sponsored Content is a special paid section where industry companies provide high quality, objective, non-commercial content around topics of interest to The News audience. All Sponsored Content is supplied by the advertising company and any opinions expressed in this article are those of the author and not necessarily reflect the views of The News or its parent company, BNP Media. Interested in participating in our Sponsored Content section? Contact your local rep!

close
  • Piggy Bank
    Sponsored byWatercress Financial

    Energy Prices, Inflation, and HVAC: What Today’s Homeowners Care About

  • Refrigerated Food
    Sponsored bySolstice Advanced Materials

    R-455A Refrigeration: A Cold Storage Solution for the Future

  • Airex Rooftop Units
    Sponsored byAirex Manufacturing Inc

    Consolidating Roof Penetrations: A Growing Trend in Multifamily HVAC Design

Popular Stories

HVAC-Price-Increase-graphic

HVAC Price Increase List: June 2026

Trump-Section-232.jpg

Trump Reduces Section 232 Tariffs on HVAC Equipment to 15%

R410A-Refrigerant-Cylinder.jpg

Refrigerant Recovery is a Revenue Opportunity

Heat-pump-cutaway.jpg

PFAS Rules and A2L Building Codes Continue to Evolve

Kroger.jpg

Kroger to Spend $100 Million to Reduce Refrigerant Leaks

View The ACHR NEWS
Centennial Anniversary Timeline

The ACHR News Timeline Chart
Submit a Letter
Submit a letter to our editors.

Events

November 6, 2025

Next-Gen Data Center Cooling: HVAC Innovation and Real-World Solutions

On Demand As AI workloads and high-density computing push traditional cooling methods to their limits, the data center industry is accelerating the adoption of next-generation HVAC technologies.

June 17, 2026

Decarbonization Without Disruption

This webinar will explore practical HVAC decarbonization strategies that minimize disruption while maximizing long-term performance and ROI.

View All Submit An Event

Poll

Summer Staff

Are you fully staffed for the summer season?
View Results Poll Archive

Products

BNI Mechanical/Electrical Square Foot Costbook, 2026 Edition

BNI Mechanical/Electrical Square Foot Costbook, 2026 Edition

See More Products
Decarbonization Without Disruption - Free Webinar - 6/17/2026

Related Articles

  • The Hotline: 07/05/2004

    See More
  • The Hotline: 06/07/2004

    See More
  • The Hotline: 06/07/2004

    See More

Related Products

See More Products
  • Modern Geothermal HVAC Engineering and Control Applications

  • Uncomplicating The Heat Pump: Refrigeration & Air Flow Systems DVD

See More Products

Related Directories

  • The Whalen Co.

    The Whalen Company is the pioneering manufacturer of HVAC vertical stack riser heat-exchanger fan coil units and water-source heat pumps for hotels, apartments and other multi-story buildings.
×

Sign Up. Stay Informed.

The #1 trusted source for the HVACR industry since 1926

SUBSCRIBE
  • RESOURCES
    • Advertise
    • Contact Us
    • Advisory Board
    • Classifieds
    • Submit a Letter
    • Directories
    • Store
  • ACCOUNT CENTER
    • Create an Account
    • Start a Subscription
    • Manage My Account
    • Sign Up for Newsletters
    • Visit Customer Service
    • Update Preferences
  • SERVICES
    • Marketing Services
    • Reprints
    • Market Research
    • List Rental
    • Survey/Respondent Access
  • STAY CONNECTED
    • LinkedIn
    • Facebook
    • Instagram
    • YouTube
    • X (Twitter)
  • PRIVACY
    • PRIVACY POLICY
    • TERMS & CONDITIONS
    • DO NOT SELL MY PERSONAL INFORMATION
    • PRIVACY REQUEST
    • ACCESSIBILITY

Copyright ©2026. All Rights Reserved BNP Media, Inc. and BNP Media II, LLC.

Design, CMS, Hosting & Web Development :: ePublishing