ACHR News
search
Ask ACHR NEWS AI
cart
facebook twitter instagram linkedin youtube
  • Sign In
  • Subscribe
  • Sign Out
  • My Account
ACHR News
  • NEWS
    • Breaking News
    • New HVAC Products
    • Featured Products
    • Manufacturer Reports
    • HVAC Data
    • Legislation
    • ACHR NEWS Centennial
  • RESIDENTIAL
    • Air Conditioners
    • Furnaces
    • Residential Heat Pumps
    • Ductless
    • Residential IAQ
    • Testing, Monitoring, Tools
    • Components & Accessories
  • COMMERCIAL
    • Air Handlers
    • Rooftop Units
    • Chillers and Cooling Towers
    • Commercial Heat Pumps
    • Boilers and Hydronics
    • VRF/Ductless
    • Commercial IAQ
  • REFRIGERATION
    • Refrigerants
    • Refrigerant Regulations
    • Leak Management
  • CONTRACTOR PRO
    • Geothermal
    • Homeowner Study
    • VRF and VRV Ductless
    • Unitary Trends
  • EDUCATION
    • Training and Education
    • Business Management
    • Service and Maintenance
    • Continuing Education
    • Market Research >
      • HVAC Brand Awareness Report
      • VRV, VRF, VRVZ Report
      • Unitary Trends Report
      • Water Heat Professionals Report
    • Webinars
    • Sponsor Insights
    • eProducts Info
    • White Papers
  • EVENTS
    • HVAC Contractor Forum
    • Industry Events and Webinars
  • MEDIA
    • Videos
    • AHR Expo 2025 Videos
    • Podcasts >
      • ACHR News Podcast
      • HARDI Podcasts
      • AHR Expo Podcasts
      • ACCA Podcasts
    • Interactive Spotlights
    • Quizzes
    • eBooks
    • HVAC Talkback
  • HVAC GROUP
    • ACHR NEWS >
      • Current Issue
      • Digital Edition
      • Subscribe
    • Distribution Trends
    • SNIPS NEWS >
      • Join SNIPS NEWS
    • Engineered Systems News >
      • Join ES News
    • HVACR Directory
    • Contests
    • Newsletters
    • Contact
    • Advertise
    • My Account
HVAC ContractingTechnical

Why Multiple Boilers Make Sense

March 18, 2005
Whether you are faced with replacing an old, large hot water boiler, or when designing a new hydronic heating system, you must decide whether to install one large hot water boiler or multiple smaller boilers. Although most systems are designed around one large boiler, when you think about how most heating systems operate, multiple smaller boilers can make a lot of sense.

The first thing you want to do is perform a heat loss calculation. By establishing the true load on the building, the replacement boiler or boilers will not be oversized. However, the conditions we use to establish the heat loss of the building are assumed to be at design conditions, which means the coldest day of the year. If you want this capability, then you need to size the boiler or boilers for this maximum load. But, there are other considerations.

The Pitfalls Of Over-Sizing

Remember that the typical design conditions exist for less than 5 percent of the heating season. If you choose to use one large boiler, it will be oversized for 95 percent of the heating season. Oversized boilers generally do not operate very efficiently because there will be frequent on/off cycling since the load is generally less than what the boiler is capable of producing. Boiler manufacturers provide efficiency ratings that indicate how efficiently their boilers use a therm of gas or a gallon of oil. When testing for these efficiencies, the boiler is running at full capacity in a "steady state." However, in the real world, the boiler rarely operates at a steady state, and therefore it never realizes its rated efficiency.

With multiple smaller boilers, when the load on the building is light, only one of the boilers may be required to heat the space. This smaller boiler will operate for a long run cycle, increasing its operating efficiency, while the other boilers remain "off," keeping the building owner happy because he is not wasting fuel.

Typical multiple boiler system.

Primary/Secondary Pumping

When using multiple boilers to achieve all the potential efficiency gains, you must prevent water from flowing through the "off" boilers. The reason: whenever you have hot water flowing through an off boiler, the boiler becomes a radiator, wasting energy in the process.

There are several methods available to prevent this unwanted flow from occurring through the off boilers, but the best method is to pipe them by using the technique called primary/secondary pumping, whereby each boiler has its own circulator which is sized just for the flow rate and pressure drop of its boiler.

The boilers are piped into a manifold, which is connected to the primary loop through a set of closely spaced tees. Piped this way, the primary loop circulator will not create flow through any of the boilers. The circulator on the individual boiler will cause the only flow that occurs.

Owner Benefits

A multiple boiler system gives the building owner these features and benefits:

Built-in redundancy. Because design conditions typically exist for only 3-5 percent of the heating season, if one of the smaller, multiple boilers goes down, the remaining boilers will meet the building's heating load.

Off-the-shelf high-efficiency boilers can be used to satisfy the heat load in light commercial applications. The boiler plant thus operates at higher efficiencies and replacement parts are easily accessible.

Smaller packaged residential boilers may be used in some commercial buildings, instead of bringing in commercial sections and constructing the boiler in place.

Looking for quick answers on air conditioning, heating and refrigeration topics? Try Ask ACHR NEWS, our new smart AI search tool. Ask ACHR NEWS →

Large domestic hot water loads in commercial and large residential applications can be met with multiple boilers. The staging control will fire the appropriate number of boilers to satisfy both the heating and domestic water load, and then shut them off as the domestic load is satisfied.

Summer operation efficiencies can be realized in some commercial applications where the only load is domestic hot water. Here, a staging control will fire only the appropriate number of boilers to satisfy the domestic water load, no matter how heavy or light.

Reprinted with permission from the Bell & Gossett newsletter CounterPointâ„¢, volume 11, issue 1, June 2004. For more information, visit the Bell & Gossett Web site at www.bellgossett.com.

Publication date: 03/21/2005

Share This Story

Looking for a reprint of this article?
From high-res PDFs to custom plaques, order your copy today!

 

Recommended Content

JOIN TODAY
To unlock your recommendations.

Already have an account? Sign In

  • HVAC-enrollment

    The Trades Are Back: HVACR Programs See Nearly 30% Enrollment Spike

    A new wave of future technicians is entering the pipeline.  
    News
    By: Matt Jachman
  • 2025 Top 40 Under 40

    2025 Top 40 Under 40 HVACR Professionals List

    The 11th annual Top 40 Under 40 list highlights those...
    HVAC Residential Market
    By: Hannah Belloli-Oster
  • LG Ductless Mini-Split Systems

    The 9 Types of Heat Pumps

    As the U.S. moves toward electrification, heat pumps are...
    HVAC Commercial Market
    By: Joanna R. Turpin
Subscription Center
  • Create an Account
  • Start a Subscription
  • Manage My Account
  • Sign Up for Newsletters
  • Visit Customer Service
  • Update Preferences

More Videos

Sponsored Content

Sponsored Content is a special paid section where industry companies provide high quality, objective, non-commercial content around topics of interest to The News audience. All Sponsored Content is supplied by the advertising company and any opinions expressed in this article are those of the author and not necessarily reflect the views of The News or its parent company, BNP Media. Interested in participating in our Sponsored Content section? Contact your local rep!

close
  • Piggy Bank
    Sponsored byWatercress Financial

    Energy Prices, Inflation, and HVAC: What Today’s Homeowners Care About

  • Refrigerated Food
    Sponsored bySolstice Advanced Materials

    R-455A Refrigeration: A Cold Storage Solution for the Future

  • Airex Rooftop Units
    Sponsored byAirex Manufacturing Inc

    Consolidating Roof Penetrations: A Growing Trend in Multifamily HVAC Design

Popular Stories

Outdoor-condensing-units.jpg

EPA Removes R-410A Installation Deadline

Trump-Section-232.jpg

Trump Reduces Section 232 Tariffs on HVAC Equipment to 15%

HVAC-Price-Increase-graphic

HVAC Price Increase List: June 2026

cooling-habits.jpg

50 Percent of Americans Have Skipped HVAC Maintenance

ACHR NEWS Editor Chris Gray Presenting HVAC Minute 5-18-2026

HVAC Manufacturers Fight Pricing Lawsuits

View The ACHR NEWS
Centennial Anniversary Timeline

The ACHR News Timeline Chart
Submit a Letter
Submit a letter to our editors.

Events

November 6, 2025

Next-Gen Data Center Cooling: HVAC Innovation and Real-World Solutions

On Demand As AI workloads and high-density computing push traditional cooling methods to their limits, the data center industry is accelerating the adoption of next-generation HVAC technologies.

June 9, 2026

Before You Go All In on AI: Set Up Your Business to Actually Win

In this webinar, we'll walk you through exactly what to get in place before you add AI to your business. You'll leave with a clear picture of where you stand today and a practical action plan to set yourself up for real results.

View All Submit An Event

Poll

EPA Decision

Are you happy the EPA decided contractors can continue to install R-410A equipment?
View Results Poll Archive

Products

BNI Mechanical/Electrical Square Foot Costbook, 2026 Edition

BNI Mechanical/Electrical Square Foot Costbook, 2026 Edition

See More Products
A2L Refrigerants - Free Webinar - May 21, 2026

Related Articles

  • Why Hybrid Systems Make Sense

    See More
  • Geothermal Checklist: Does Your Project Make Sense?

    See More
  • Daikin-ODU-Heat-Pump---tech-install.png

    When Does a Compressor Swap Still Make Sense?

    See More

Related Products

See More Products
  • Lessons Learned in a Boiler Room: A common sense approach to servicing and installing commercial boilers

  • fanfelaysdvd.jpg

    Understanding Fan Relays and Multiple Speed Motors

  • ghpm.png

    Gas Heating: Furnaces, Boilers, Controls, Components

See More Products

Events

View AllSubmit An Event
  • June 23, 2026

    HVAC Duct Sealing Mastics: Why Selection Matters

    In this webinar we will detail what HVAC material buyers and technicians need to know when selecting duct mastics, including matching mastic to substrate, alternatives to liquid mastic, and where UL 181 Listings fit into real world installations.
  • December 9, 2025

    Beyond Smart Buildings: Why BMS Needs to Move Past Division 23 — For Every Building

    On Demand Let’s reframe Division 25 not as a lofty ideal, but as a practical and alternate approach to specifying facility systems such as a building management systems (BMS).
View AllSubmit An Event

Related Directories

  • Rite Boiler

    Rite manufactures and provides Low- and High-Pressure Steam Boilers, Hot Water Boilers, Blowdown Tanks, Boiler Feed System, Water Softeners, Chemical Feed Systems, and more.
×

Sign Up. Stay Informed.

The #1 trusted source for the HVACR industry since 1926

SUBSCRIBE
  • RESOURCES
    • Advertise
    • Contact Us
    • Advisory Board
    • Classifieds
    • Submit a Letter
    • Directories
    • Store
  • ACCOUNT CENTER
    • Create an Account
    • Start a Subscription
    • Manage My Account
    • Sign Up for Newsletters
    • Visit Customer Service
    • Update Preferences
  • SERVICES
    • Marketing Services
    • Reprints
    • Market Research
    • List Rental
    • Survey/Respondent Access
  • STAY CONNECTED
    • LinkedIn
    • Facebook
    • Instagram
    • YouTube
    • X (Twitter)
  • PRIVACY
    • PRIVACY POLICY
    • TERMS & CONDITIONS
    • DO NOT SELL MY PERSONAL INFORMATION
    • PRIVACY REQUEST
    • ACCESSIBILITY

Copyright ©2026. All Rights Reserved BNP Media, Inc. and BNP Media II, LLC.

Design, CMS, Hosting & Web Development :: ePublishing