The Anti-Sweat Module (ASM-115) for glass door walk-ins alleviates condensation buildup on glass doors and frames. The module runs heaters when the door surface temperature is lower than the dew point. An exterior-mounted doorframe sensor modulates the door and frame heaters as needed. The sensor is designed to automatically shut off glass and frame door heaters when door heat is unnecessary. The sensor is mounted to the coldest part of the doorframe, usually putting it directly in front of the electrical connections on the opposite side of the frame. The body of the ASM-115 is mounted to the walk-in roof, or a location that is clear of product stacking and other items that might cause damage to the unit. The ASM-115 meets California energy standards.

Master-Bilt, 908 Highway 15 North, New Albany, MS 38652; 800-647-1284; 800-232-3966 (fax); sales@master-bilt; www.master-bilt.com