ACHR News
search
Ask ACHR NEWS AI
cart
facebook twitter instagram linkedin youtube
  • Sign In
  • Subscribe
  • Sign Out
  • My Account
ACHR News
  • NEWS
    • Breaking News
    • New HVAC Products
    • Featured Products
    • Manufacturer Reports
    • HVAC Data
    • Legislation
    • ACHR NEWS Centennial
  • RESIDENTIAL
    • Air Conditioners
    • Furnaces
    • Residential Heat Pumps
    • Ductless
    • Residential IAQ
    • Testing, Monitoring, Tools
    • Components & Accessories
  • COMMERCIAL
    • Air Handlers
    • Rooftop Units
    • Chillers and Cooling Towers
    • Commercial Heat Pumps
    • Boilers and Hydronics
    • VRF/Ductless
    • Commercial IAQ
  • REFRIGERATION
    • Refrigerants
    • Refrigerant Regulations
    • Leak Management
  • CONTRACTOR PRO
    • Geothermal
    • Homeowner Study
    • VRF and VRV Ductless
    • Unitary Trends
  • EDUCATION
    • Training and Education
    • Business Management
    • Service and Maintenance
    • Continuing Education
    • Market Research >
      • HVAC Brand Awareness Report
      • VRV, VRF, VRVZ Report
      • Unitary Trends Report
      • Water Heat Professionals Report
    • Webinars
    • Sponsor Insights
    • eProducts Info
    • White Papers
  • EVENTS
    • HVAC Contractor Forum
    • Industry Events and Webinars
  • MEDIA
    • Videos
    • AHR Expo 2025 Videos
    • Podcasts >
      • ACHR News Podcast
      • HARDI Podcasts
      • AHR Expo Podcasts
      • ACCA Podcasts
    • Interactive Spotlights
    • Quizzes
    • eBooks
    • HVAC Talkback
  • HVAC GROUP
    • ACHR NEWS >
      • Current Issue
      • Digital Edition
      • Subscribe
    • Distribution Trends
    • SNIPS NEWS >
      • Join SNIPS NEWS
    • Engineered Systems News >
      • Join ES News
    • HVACR Directory
    • Contests
    • Newsletters
    • Contact
    • Advertise
    • My Account
HVAC ContractingService and Maintenance

Btu Buddy 59: High Power Bills With a Heat Pump

By Bill Johnson
February 18, 2008

Bob is a service technician who is well trained and nationally certified. However, he sometimes suffers from the same confusion that all technicians occasionally do - the facts that he gathers may or may not point to the obvious cause of the problem or the best solution. But Bob has something that no one else has. He recalls his long-time HVACR mentor and imagines him accompanying him as “Btu Buddy,” someone who reminds him to take time to stop and think before rushing to judgment, helping keep him on the right track, even with facts that are confusing.

Bob was called to a new customer’s home that had a 5-ton heat pump. The home was a large ranch style home, all on one floor. The customer met Bob at the door and she explained to him that her power bills were considerably higher than the same months last year. Bob looked at the comparison and agreed. The seasons were similar, but the bills for this year were much higher.

Bob then went to the indoor air handler under the house and looked at the filter. All seemed normal with them.

He then went to the outside unit and looked around and nothing stood out to be a problem. He then went inside and checked the outlet temperature at one of the room registers. The temperature was 120°F. He then went to the room thermostat and checked the thermostat to see if the strip heat was calling for heat and it was not. He was looking confused when Btu Buddy appeared and asked, “What is the problem, Bob?”

Figure 1. This electric heat element is grounded to the frame of the furnace causing it to produce heat all of the time. (From Practical Heating Technology by William Johnson, published by Delmar Cengage Learning.)

Bob explained what he knew and asked Btu Buddy for some advice.

Btu Buddy said, “Check for amp draw at the strip heaters on both lines going to the heaters. Remember the time you had a strip heater that was grounded and it was drawing current all the time (Figure 1)?”

Bob got his ammeter from the truck and went under the house and checked all three strip heaters and there was no current flow. Bob then asked, “Now what?”

Btu Buddy then said, “You have ruled out heat from any source except the heat pump refrigerant cycle, so the excess heat must be coming from the heat pump coil itself. With an air discharge temperature like you are getting, I would suggest that you have a reduced airflow. A heat pump should not have a discharge temperature above about 105° and this one is running 120°. Feel the liquid line and tell me if it feels normal.”

Bob put his hand on the liquid line and exclaimed, “Boy, that line is really hot. Normally it would be about hand temperature, but that could burn you if you held it for long.”

“What does that tell you, Bob?” asked Btu Buddy.

“It tells me that the air stream is not taking the heat out of the refrigerant condenser coil, which is the indoor coil in the heat cycle,” said Bob.

Btu Buddy then asked, “What could be some reasons for these symptoms?”

Figure 2. This illustration shows several places where airflow can be blocked in an air distribution system. (From Refrigeration & Air Conditioning Technology, 5th Edition, by William Whitman, William Johnson, and John Tomczyk, published by Delmar Cengage Learning.)

Bob answered, “The filter could be stopped up, the coil could be dirty, the fan may not be moving enough air, trash in the ductwork, insulation may have come loose and dropped down, supply registers or return grilles may be restricted are possibilities (Figure 2). The duct is insulated on the outside, so there shouldn’t be any insulation on the inside that could be loose and cause a restriction.”

Btu Buddy then said, “Then you must eliminate those possibilities one at the time. It may be a combination of several of those things.”

Bob said, “I never thought of it being more than one thing. Most all of the trouble calls that I have worked on get back to one problem.”

Btu Buddy said, “That is usually the case. Let’s go do some checking. The simplest things to check would be the supply registers and return air grilles. I noticed that this house has multiple returns, so be sure to check them all.”

Bob went from room to room and checked the airflow possibilities and told Btu Buddy, “I found several rooms that both the supply and return fixtures were shut off. I talked to the homeowner and she said she was trying to save money by not heating those rooms. I explained to her that closing those fixtures was at least part of the problem.”

Btu Buddy said, “Now check the liquid line temperature.”

Bob held the liquid line and said, “That is much better. I think I will check the temperature with my thermistor temperature tester.”

After the check, Bob said, “The temperature is still 107°. I am not sure that we have gotten to the bottom of this problem.”

Btu Buddy then said, “Good point, check further.”

Bob looked at the fan wheel and commented, “The fan wheel has a lot of dirt in the curves of the wheel. I think I will clean the wheel.”

“Good point, Bob”, said Btu Buddy. “If the fan wheel is dirty, where did the dirt come from?”

Bob responded, “It had to come through the filters. At some point the filters must have been really dirty and let dirt pass.”

Btu Buddy then said, “Most filters only get the larger particles of dirt; much of the fine dirt slips through. In the summer, the coil is wet and acts as a super filter. I would suspect that the coil is dirty also.”

Bob got set up and cleaned the fan wheel and the coil, and said, “I can’t believe how much dirt came out of the core of that coil. It is a good thing I had this pressure washer. It just kept pushing out dirt. That especially made detergent for coils really did the trick.”

When Bob got the system back together, he started the unit up and after it had run for about 20 minutes, he looked at the temperature of the liquid line and said, “The temperature is down to 100°. That works for me.”

Btu Buddy suggested, “Bob, you need to check the outlet air temperature now that you have made these changes.”

Bob went in the house and checked the air temperature at the same place he had checked before and the temperature was 100°.

Bob went back outside with Btu Buddy and told him the results and Btu Buddy said, “Now you have confidence that you got to the complete bottom of the situation. Be sure and talk to the homeowner and tell her what you did. Be sure and mention the outlet air temperatures will be lower, but that the system will be more efficient.”

Bob asked, “Why didn’t you suggest that we put gauges on the system and check the pressures?”

Btu Buddy explained, “You could have connected your gauges. However, we came to the same conclusions without installing gauges. Remember, every time you fasten your gauges, you let out some refrigerant. The system has a critical charge and you may alter the charge when connecting the gauges. Also, you always have the possibility of leaving a leak behind and then you would be called back to the same job later to add refrigerant.”

Bob then said, “None of that would be good.”

Bob talked to the homeowner and explained everything to her and she understood to leave all airflows alone.

When riding away, Bob asked Btu Buddy why high head pressure resulted in such a dramatic change in power consumption in a heat pump and Btu Buddy said, “Let’s go to lunch and talk about it. Bring your text book so we can discuss some examples.”

Publication date: 02/18/2008

Share This Story

Looking for a reprint of this article?
From high-res PDFs to custom plaques, order your copy today!

 

Active in the HVACR industry since the 1950s, Bill Johnson graduated in gas fuel technology and refrigeration from the Southern Technical Institute, a branch of Georgia Tech (now known as Southern Polytechnic Institute). He taught HVAC classes at Coosa Valley Vocational & Technical Institute for four years. He moved on to become service manager for Layne Trane, Charlotte, N.C. He taught for 15 years at Central Piedmont Community College, part of this time as program director. He had his own business for five years doing installation and service work. Now retired, he is the author of Practical Heating Technology and Practical Cooling Technology, and continues as a co-author of Refrigeration & Air Conditioning Technology, seventh edition, all published by Delmar Cengage Learning. For more information, he can be reached at 704-968-0000 or thebillj1@gmail.com.

Btu Buddy Notebook is a collection of more than 50 service call scenarios in book form covering both cooling season and heating season troubleshooting. For more information and to purchase the book, visit the HVACR Industry Store.

Recommended Content

JOIN TODAY
To unlock your recommendations.

Already have an account? Sign In

  • HVAC-enrollment

    The Trades Are Back: HVACR Programs See Nearly 30% Enrollment Spike

    A new wave of future technicians is entering the pipeline.  
    News
    By: Matt Jachman
  • 2025 Top 40 Under 40

    2025 Top 40 Under 40 HVACR Professionals List

    The 11th annual Top 40 Under 40 list highlights those...
    HVAC Residential Market
    By: Hannah Belloli-Oster
  • LG Ductless Mini-Split Systems

    The 9 Types of Heat Pumps

    As the U.S. moves toward electrification, heat pumps are...
    HVAC Residential Market
    By: Joanna R. Turpin
Subscription Center
  • Create an Account
  • Start a Subscription
  • Manage My Account
  • Sign Up for Newsletters
  • Visit Customer Service
  • Update Preferences

More Videos

Sponsored Content

Sponsored Content is a special paid section where industry companies provide high quality, objective, non-commercial content around topics of interest to The News audience. All Sponsored Content is supplied by the advertising company and any opinions expressed in this article are those of the author and not necessarily reflect the views of The News or its parent company, BNP Media. Interested in participating in our Sponsored Content section? Contact your local rep!

close
  • Piggy Bank
    Sponsored byWatercress Financial

    Energy Prices, Inflation, and HVAC: What Today’s Homeowners Care About

  • Refrigerated Food
    Sponsored bySolstice Advanced Materials

    R-455A Refrigeration: A Cold Storage Solution for the Future

  • Airex Rooftop Units
    Sponsored byAirex Manufacturing Inc

    Consolidating Roof Penetrations: A Growing Trend in Multifamily HVAC Design

Popular Stories

Refrigerants-and-gauge.jpg

HVAC Industry Warns of Counterfeit Refrigerants Entering U.S. Supply Chain

U.S. Supreme Court building

95% Furnace Efficiency Rule to Get New Hearing

Midea-training.jpg

HVAC Workforce Crisis Expands Beyond Technicians to Instructor Shortages

Data_Center_facility.jpg

HVAC Manufacturers Respond to Growing Data Center Backlash

HVAC Minute retail refrigeration system

EPA Final Rule’s Impact on R-410A Deadlines

View The ACHR NEWS
Centennial Anniversary Timeline

The ACHR News Timeline Chart
Submit a Letter
Submit a letter to our editors.

Events

November 6, 2025

Next-Gen Data Center Cooling: HVAC Innovation and Real-World Solutions

On Demand As AI workloads and high-density computing push traditional cooling methods to their limits, the data center industry is accelerating the adoption of next-generation HVAC technologies.

June 23, 2026

HVAC Duct Sealing Mastics: Why Selection Matters

In this webinar we will detail what HVAC material buyers and technicians need to know when selecting duct mastics, including matching mastic to substrate, alternatives to liquid mastic, and where UL 181 Listings fit into real world installations.

View All Submit An Event

Poll

Summer Staff

Are you fully staffed for the summer season?
View Results Poll Archive

Products

BNI Mechanical/Electrical Square Foot Costbook, 2026 Edition

BNI Mechanical/Electrical Square Foot Costbook, 2026 Edition

See More Products
HVAC Duct Sealing Mastics: Why Selection Matters - Free Webinar - 6/23/2026

Related Articles

  • Btu Buddy 142: High Power Bill with a Heat Pump

    See More
  • Btu Buddy 94: A Heat Pump That's Not Getting Up to Temperature

    See More
  • Btu Buddy 44: Stolen Outdoor Unit for a Heat Pump

    See More

Related Products

See More Products
  • A-Heat-Pump-That-Won__t-Cool-DVD-Cover-214x300.jpg

    A Heat Pump That Won't Cool

  • A-Heat-Pump-Thats-Not-Delivering-Any-Air-DVD-Cover-218x300.jpg

    A Heat Pump That’s Not Delivering Any Air

  • HPOIS.png

    Heat Pump Operation, Installation, Service

See More Products

Related Directories

  • BP Porter Inc. (Heat Pump Controls/Thermostats)

    BP Porter Inc., the products of this company BPC-1 Bill Porter Control (a fossil fuel control) and BPC-ODS micro'stat was developed (invented) by Bill Porter, an HVAC technician in early 1994.
  • IGSHPA-International Ground Source Heat Pump Assn.

    IGSHPA is an association of companies, professionals and users dedicated to promoting the science, utility and use of geothermal (ground source) heating and cooling technology.
×

Sign Up. Stay Informed.

The #1 trusted source for the HVACR industry since 1926

SUBSCRIBE
  • RESOURCES
    • Advertise
    • Contact Us
    • Advisory Board
    • Classifieds
    • Submit a Letter
    • Directories
    • Store
  • ACCOUNT CENTER
    • Create an Account
    • Start a Subscription
    • Manage My Account
    • Sign Up for Newsletters
    • Visit Customer Service
    • Update Preferences
  • SERVICES
    • Marketing Services
    • Reprints
    • Market Research
    • List Rental
    • Survey/Respondent Access
  • STAY CONNECTED
    • LinkedIn
    • Facebook
    • Instagram
    • YouTube
    • X (Twitter)
  • PRIVACY
    • PRIVACY POLICY
    • TERMS & CONDITIONS
    • DO NOT SELL MY PERSONAL INFORMATION
    • PRIVACY REQUEST
    • ACCESSIBILITY

Copyright ©2026. All Rights Reserved BNP Media, Inc. and BNP Media II, LLC.

Design, CMS, Hosting & Web Development :: ePublishing