ACHR News
search
Ask ACHR NEWS AI
cart
facebook twitter instagram linkedin youtube
  • Sign In
  • Subscribe
  • Sign Out
  • My Account
ACHR News
  • NEWS
    • Breaking News
    • New HVAC Products
    • Featured Products
    • Manufacturer Reports
    • HVAC Data
    • Legislation
    • ACHR NEWS Centennial
  • RESIDENTIAL
    • Air Conditioners
    • Furnaces
    • Residential Heat Pumps
    • Ductless
    • Residential IAQ
    • Testing, Monitoring, Tools
    • Components & Accessories
  • COMMERCIAL
    • Air Handlers
    • Rooftop Units
    • Chillers and Cooling Towers
    • Commercial Heat Pumps
    • Boilers and Hydronics
    • VRF/Ductless
    • Commercial IAQ
  • REFRIGERATION
    • Refrigerants
    • Refrigerant Regulations
    • Leak Management
  • CONTRACTOR PRO
    • Geothermal
    • Homeowner Study
    • VRF and VRV Ductless
    • Unitary Trends
  • EDUCATION
    • Training and Education
    • Business Management
    • Service and Maintenance
    • Continuing Education
    • Market Research >
      • HVAC Brand Awareness Report
      • VRV, VRF, VRVZ Report
      • Unitary Trends Report
      • Water Heat Professionals Report
    • Webinars
    • Sponsor Insights
    • eProducts Info
    • White Papers
  • EVENTS
    • HVAC Contractor Forum
    • Industry Events and Webinars
  • MEDIA
    • Videos
    • AHR Expo 2025 Videos
    • Podcasts >
      • ACHR News Podcast
      • HARDI Podcasts
      • AHR Expo Podcasts
      • ACCA Podcasts
    • Interactive Spotlights
    • Quizzes
    • eBooks
    • HVAC Talkback
  • HVAC GROUP
    • ACHR NEWS >
      • Current Issue
      • Digital Edition
      • Subscribe
    • Distribution Trends
    • SNIPS NEWS >
      • Join SNIPS NEWS
    • Engineered Systems News >
      • Join ES News
    • HVACR Directory
    • Contests
    • Newsletters
    • Contact
    • Advertise
    • My Account

Symptom-Cause Troubleshooting

June 2, 2002
Figure 1. Electrical schematic diagram with a time clock controlling a defrost circuit and a refrigeration circuit.
Many service technicians troubleshoot refrigeration and air conditioning systems on a daily basis. Learning the most efficient methods of troubleshooting not only saves the service technician’s time, but also the customer’s money. Good, systematic troubleshooting techniques offer a win-win situation for both customer and technician.

This article presents an example of a systematic troubleshooting method incorporating the symptom-cause method.

Figure 1 illustrates an electrical schematic diagram showing a time clock controlling a defrost circuit and a refrigeration circuit. Notice in the refrigeration circuit that the compressor’s run winding has been opened from a motor overheating problem.

The service call is a “no-cooling” call for a low-temperature walk-in cooler. Once the technician quickly looks the system over and listens for any clues of what the problem may be, he should study the electrical schematic, if available. Understanding the logic or sequencing of the circuits before diving head over heels into the problem is of the utmost importance.

In this scenario, an open run winding gives certain symptoms that will not exist for other possible system problems. For example, the technician listened to and examined the refrigeration system, then studied the electrical schematic drawing. He then listed the symptoms.

SYMPTOMS

  • Compressor motor hums and will not turn.

  • Compressor motor draws locked rotor amps (LRA).

  • Compressor motor’s overload trips soon after drawing LRA; resets after 2 min.

    The technician then turns power off to the refrigeration system to let the motor cool down. After studying the electrical diagram again, the technician lists some possible causes that will correlate to every symptom listed. If a possible cause does not correlate to every symptom listed, it cannot be a possible cause.

    POSSIBLE CAUSES

  • Open start winding;

  • Open run winding;

  • Open run capacitor;

  • Open start capacitor;

  • Compressor mechanically stuck; or

  • Potential relay contacts between 1 and 2 stuck open.

    Notice that every possible cause listed correlated to all of the symptoms. All the technician has to do is check only these six possible causes to find out which one is causing the symptoms, instead of blindly checking out the entire system.

    With the power off, the technician takes a wire off of the start winding and ohms the winding. The technician finds that it has 4 ohms, meaning that it is not open. The technician now takes a wire off of the run winding and ohms that winding. The technician finds that it is an open winding because of the infinity reading on the ohmmeter. The compressor has to be replaced. With either winding open, the compressor has no phase shift for starting and will lock its rotor, drawing LRA until the overload trips.

    If either capacitor was bad, the motor may not have had enough phase shift to start. This is especially true if the motor was under a high load. In certain cases, the motor may slowly turn. If the compressor was mechanically stuck (for example, if something was wedged between the piston and cylinder), the motor would lock its rotor and draw LRA.

    If the contacts between terminals 1 and 2 of the potential relay were stuck open for some reason, the start capacitor would be out of the circuit. This again probably will not cause enough phase shift to start the motor turning. The motor would again draw LRA.

    Notice that in every case, all symptoms were met.

    IMPROBABLE CAUSES

    What about an open overload, or an open potential relay coil between terminals 2 and 5 of the potential relay? If the overload were opened at the beginning, maybe from too high of a compressor amp draw, the compressor would not hum or draw LRA. This would not correlate with all of the symptoms listed and could not be a possible cause.

    If the coil of the potential relay was open, the contacts between 1 and 2 of the potential relay would stay in their normally closed position and would not open. This would cause the start capacitor to be in the circuit all the time. The motor would turn, drawing higher-than-normal amperage, and eventually open the overload. These symptoms do not correlate with the original symptoms listed, thus they cannot be a possible cause.

    Once the technician has replaced the compressor and the system is up and running, it is important to run a system check to see what caused the compressor overheating that opened the winding. Evaporator superheat, total superheat, condenser subcooling — along with suction pressure and head pressure — must be taken for the system check.

    In this case, the technician took a system check and found the evaporator superheat to be very high at 40 degrees F and the total superheat to be a very high 90 degrees. Condenser subcooling was fine at 12 degrees. Both suction and head pressures were low (see Table 1).

    THE SOLUTION

    The problem that caused the overheating was a faulty thermostatic expansion valve. The valve would not open enough and the entire low side of the system was being starved. The compressor was refrigerant-cooled. This caused the compressor to overheat and cycle on its overload until the run winding finally opened.

    Without this final system check, the new compressor surely would have failed in a short time.

    Tomczyk is a professor of hvac at Ferris State University, Big Rapids, MI, and the author of Troubleshooting and Servicing Modern Air Conditioning & Refrigeration Systems, published by ESCO Press. To order, call 800-726-9696. Tomczyk can be reached at tomczykj@tucker-usa.com (e-mail).

    Publication date: 06/03/2002

  • Looking for quick answers on air conditioning, heating and refrigeration topics? Try Ask ACHR NEWS, our new smart AI search tool. Ask ACHR NEWS →

    Share This Story

    Looking for a reprint of this article?
    From high-res PDFs to custom plaques, order your copy today!

     

    Recommended Content

    JOIN TODAY
    To unlock your recommendations.

    Already have an account? Sign In

    • HVAC-enrollment

      The Trades Are Back: HVACR Programs See Nearly 30% Enrollment Spike

      A new wave of future technicians is entering the pipeline.  
      News
      By: Matt Jachman
    • 2025 Top 40 Under 40

      2025 Top 40 Under 40 HVACR Professionals List

      The 11th annual Top 40 Under 40 list highlights those...
      HVAC Light Commercial Market
      By: Hannah Belloli-Oster
    • LG Ductless Mini-Split Systems

      The 9 Types of Heat Pumps

      As the U.S. moves toward electrification, heat pumps are...
      HVAC Residential Market
      By: Joanna R. Turpin
    Subscription Center
    • Create an Account
    • Start a Subscription
    • Manage My Account
    • Sign Up for Newsletters
    • Visit Customer Service
    • Update Preferences

    More Videos

    Sponsored Content

    Sponsored Content is a special paid section where industry companies provide high quality, objective, non-commercial content around topics of interest to The News audience. All Sponsored Content is supplied by the advertising company and any opinions expressed in this article are those of the author and not necessarily reflect the views of The News or its parent company, BNP Media. Interested in participating in our Sponsored Content section? Contact your local rep!

    close
    • Piggy Bank
      Sponsored byWatercress Financial

      Energy Prices, Inflation, and HVAC: What Today’s Homeowners Care About

    • Refrigerated Food
      Sponsored bySolstice Advanced Materials

      R-455A Refrigeration: A Cold Storage Solution for the Future

    • Airex Rooftop Units
      Sponsored byAirex Manufacturing Inc

      Consolidating Roof Penetrations: A Growing Trend in Multifamily HVAC Design

    Popular Stories

    Refrigerants-and-gauge.jpg

    HVAC Industry Warns of Counterfeit Refrigerants Entering U.S. Supply Chain

    U.S. Supreme Court building

    95% Furnace Efficiency Rule to Get New Hearing

    Data_Center_facility.jpg

    HVAC Manufacturers Respond to Growing Data Center Backlash

    Midea-training.jpg

    HVAC Workforce Crisis Expands Beyond Technicians to Instructor Shortages

    HVAC Minute retail refrigeration system

    EPA Final Rule’s Impact on R-410A Deadlines

    View The ACHR NEWS
    Centennial Anniversary Timeline

    The ACHR News Timeline Chart
    Submit a Letter
    Submit a letter to our editors.

    Events

    November 6, 2025

    Next-Gen Data Center Cooling: HVAC Innovation and Real-World Solutions

    On Demand As AI workloads and high-density computing push traditional cooling methods to their limits, the data center industry is accelerating the adoption of next-generation HVAC technologies.

    June 23, 2026

    HVAC Duct Sealing Mastics: Why Selection Matters

    In this webinar we will detail what HVAC material buyers and technicians need to know when selecting duct mastics, including matching mastic to substrate, alternatives to liquid mastic, and where UL 181 Listings fit into real world installations.

    View All Submit An Event

    Poll

    Summer Staff

    Are you fully staffed for the summer season?
    View Results Poll Archive

    Products

    BNI Mechanical/Electrical Square Foot Costbook, 2026 Edition

    BNI Mechanical/Electrical Square Foot Costbook, 2026 Edition

    See More Products
    HVAC Duct Sealing Mastics: Why Selection Matters - Free Webinar - 6/23/2026

    Related Articles

    • Troubleshooting the Root Cause for a Refrigerant Starved Evaporator

      See More
    • The Professor: Symptom Variations With Different Devices

      See More
    • Electrical Schematic Diagram.

      Improving Your Systematic Troubleshooting Skills

      See More

    Related Products

    See More Products
    • Troubleshooting Tips for Servicing Refrigeration Systems

    • HVAC/R Electrical Troubleshooting: Deciding where to begin DVD

    • ttabewdip.png

      HVACR Troubleshooting Fundamentals Technician Training Package

    See More Products

    Related Directories

    • Superior Signal Co. LLC

      Superior Signal AccuTrak® Ultrasonic Leak Detectors "hear" any gas or refrigerant leak, troubleshoot expansion valves in minutes! Superior® Smoke Generators unequaled for Leak/Air Flow Testing.
    ×

    Sign Up. Stay Informed.

    The #1 trusted source for the HVACR industry since 1926

    SUBSCRIBE
    • RESOURCES
      • Advertise
      • Contact Us
      • Advisory Board
      • Classifieds
      • Submit a Letter
      • Directories
      • Store
    • ACCOUNT CENTER
      • Create an Account
      • Start a Subscription
      • Manage My Account
      • Sign Up for Newsletters
      • Visit Customer Service
      • Update Preferences
    • SERVICES
      • Marketing Services
      • Reprints
      • Market Research
      • List Rental
      • Survey/Respondent Access
    • STAY CONNECTED
      • LinkedIn
      • Facebook
      • Instagram
      • YouTube
      • X (Twitter)
    • PRIVACY
      • PRIVACY POLICY
      • TERMS & CONDITIONS
      • DO NOT SELL MY PERSONAL INFORMATION
      • PRIVACY REQUEST
      • ACCESSIBILITY

    Copyright ©2026. All Rights Reserved BNP Media, Inc. and BNP Media II, LLC.

    Design, CMS, Hosting & Web Development :: ePublishing