ACHR News
search
Ask ACHR NEWS AI
cart
facebook twitter instagram linkedin youtube
  • Sign In
  • Subscribe
  • Sign Out
  • My Account
ACHR News
  • NEWS
    • Breaking News
    • New HVAC Products
    • Featured Products
    • Manufacturer Reports
    • HVAC Data
    • Legislation
    • ACHR NEWS Centennial
  • RESIDENTIAL
    • Air Conditioners
    • Furnaces
    • Residential Heat Pumps
    • Ductless
    • Residential IAQ
    • Testing, Monitoring, Tools
    • Components & Accessories
  • COMMERCIAL
    • Air Handlers
    • Rooftop Units
    • Chillers and Cooling Towers
    • Commercial Heat Pumps
    • Boilers and Hydronics
    • VRF/Ductless
    • Commercial IAQ
  • REFRIGERATION
    • Refrigerants
    • Refrigerant Regulations
    • Leak Management
  • CONTRACTOR PRO
    • Geothermal
    • Homeowner Study
    • VRF and VRV Ductless
    • Unitary Trends
  • EDUCATION
    • Training and Education
    • Business Management
    • Service and Maintenance
    • Continuing Education
    • Market Research >
      • HVAC Brand Awareness Report
      • VRV, VRF, VRVZ Report
      • Unitary Trends Report
      • Water Heat Professionals Report
    • Webinars
    • Sponsor Insights
    • eProducts Info
    • White Papers
  • EVENTS
    • HVAC Contractor Forum
    • Industry Events and Webinars
  • MEDIA
    • Videos
    • AHR Expo 2025 Videos
    • Podcasts >
      • ACHR News Podcast
      • HARDI Podcasts
      • AHR Expo Podcasts
      • ACCA Podcasts
    • Interactive Spotlights
    • Quizzes
    • eBooks
    • HVAC Talkback
  • HVAC GROUP
    • ACHR NEWS >
      • Current Issue
      • Digital Edition
      • Subscribe
    • Distribution Trends
    • SNIPS NEWS >
      • Join SNIPS NEWS
    • Engineered Systems News >
      • Join ES News
    • HVACR Directory
    • Contests
    • Newsletters
    • Contact
    • Advertise
    • My Account
HVAC ContractingService and Maintenance

Btu Buddy 84: Condensing Furnace Problems

By Bill Johnson
March 22, 2010

Bob is a service technician who is well trained and nationally certified. However, he sometimes suffers from the same confusion that all technicians occasionally do - the facts that he gathers may or may not point to the obvious cause of the problem or the best solution. But Bob has something that no one else has. He recalls his long-time HVACR mentor and imagines him accompanying him as “Btu Buddy,” someone who reminds him to take time to stop and think before rushing to judgment, helping keep him on the right track, even with facts that are confusing.

The first call of the day already had Bob confused. It started with a call from the dispatcher who described a gas heat customer who had no heat. It was a new installation and the customer was upset because the new system was not heating. It was up to Bob to make the customer as happy as possible. The weather was really cold, 10°F at night and only 20° during the day.

Bob arrived to find an angry housewife. It was hard to be polite, but he had to. He assured the woman that he would do all in his power to get the system started quickly. Meanwhile, he recommended that she take the two children to the kitchen and put a pan of water on each stove eye to boil. This would keep the electric cooking elements from getting too hot and put some humidity in the air. He then went to the furnace in the garage.

When he got to the garage and the furnace, the first thing that he noticed was that the furnace was cold. It had not been operating. He decided to check the power supply and found that he had 24 volts at the low voltage power supply. This proved that both the low and high voltage power was on. He then checked from the common terminal to the “W” terminal to see if the thermostat was calling for heat and it was not. Now Bob was sure that the thermostat was defective.

Bob then went to the thermostat and removed it from the sub-base. He then jumped from the “R” terminal, which is the hot terminal, to the “W” terminal for heat. He was expecting the heat to come on so he went to the furnace and was surprised the furnace was not running. He was standing there confused when Btu Buddy arrived and said, “What is the problem, Bob?”

Figure 1. This wiring diagram shows where a jumper can be applied to temporarily operate the furnace. Don’t forget to remove the jumper. It is recommenced to use a long jumper that will be obvious so you won’t forget it. (From Refrigeration & Air Conditioning Technology, 5th Edition, by William Whitman, William Johnson, and John Tomczyk, published by Delmar Cengage Learning.) (©Delmar Cengage Learning.)

Bob explained what he had done and Btu Buddy said, “Why don’t you jump from ‘R’ to ‘W’ on the furnace (Figure 1)?”

Bob then said, “When I get confused, my thinking ability seems to stop.”

Bob jumped the terminals and the furnace started.

“What does that tell you, Bob?” asked Btu Buddy.

Bob said, “It tells me that the furnace will operate and the signal telling it to operate is not getting through. It has to be in the field wiring somewhere. I am going to let the furnace run while I try to figure it out.”

Bob then said, “I know the problem is in the field wiring. I think I will trace it out and try to find the problem by just observing.”

Bob then started with the wire that connected to the “W” terminal and followed it. It went for a ways and then went up in the wall towards the room thermostat. There was no visible problem.

He then started following the wire on the “R” terminal. It went to the other side of the furnace to a terminal on the condensate pump. He turned to Btu Buddy and asked, “Why would the wire go to the condensate pump? Also, the pump seems to be running. What is that all about? I thought that pump was for the air conditioning only.”

Btu Buddy then explained, “I thought you would hear that pump running when we walked in. Probably you only had your mind on why the furnace was not running and did not notice what else was happening.

Figure 2. This is a cutaway of a condensing furnace. Notice the last heat exchanger is in the return air so it can remove the most heat from the flue gases. This will condense water out of the flue gases that must be piped to a termination point. (From Refrigeration & Air Conditioning Technology, 5th Edition, by William Whitman, William Johnson, and John Tomczyk, published by Delmar Cengage Learning.) (©Delmar Cengage Learning.)

“This is a condensing furnace and it actually generates condensate. It is a 96 percent efficient furnace. It gets some of that extra efficiency by running the flue gases through an extra coil that is mounted where the cool return air passes over it (Figure 2). This cools the flue gases enough that the water in the flue gas condenses. This furnace makes enough condensate that it must be dealt with like you would with air conditioning condensate. This system has to pipe the condensate outside since the furnace is below ground level. Now you need to find out where the condensate pump line terminates.”

Bob followed the condensate line to the end and said, “The line terminates about four feet from the house under a bush.”

Btu Buddy then asked, “Is there any water on the ground?”

Bob said, “No, everything is frozen including the condensate line. I am going to cut it off closer to the house and see what happens.”

Bob then said, “Wow, water is rushing out of the line.”

Btu Buddy said, “Now take your jumper off of the furnace terminal board and see what happens.”

Bob removed the jumper and said, “The furnace is still running. I don’t get it.”

Figure 3. This shows a condensate pump that may be used for air conditioning and heating to move the condensate to a proper drain. (From Practical Cooling Technology, by William Johnson, published by Delmar Cengage Learning.) (©Delmar Cengage Learning.)

Btu Buddy explained, “The condensate pump has two float switches in it. The first one is supposed to start the pump. The second switch is wired into the hot side of the control wiring and interrupts the signal to the thermostat and neither heating or cooling will start. That is why the pump was running but the furnace would not start. It also prevented condensate from getting all over the floor. When the outlet froze solid, the next time it called for pumping out the pump reservoir, the pump started and just ran, but did not pump. It is a centrifugal pump so no damage occurred (Figure 3).”

Bob told the homeowner what had happened and she was relieved and thankful that it wasn’t a whole system failure.

As they were leaving, Bob said, “That was another brain twister. What should I have noticed first to shorten the call?”

Btu Buddy said, “The pump running was the first sign. It doesn’t make much noise, but it shouldn’t have been running all of the time. You really did the right thing by keeping the furnace running while figuring out the problem. It helped make the homeowner more comfortable as the service procedure was figured out.”

Bob then said, “Thanks again. You can’t teach me how to think, but your guidance sure helps.”

Publication date: 03/22/2010

Share This Story

Looking for a reprint of this article?
From high-res PDFs to custom plaques, order your copy today!

 

Active in the HVACR industry since the 1950s, Bill Johnson graduated in gas fuel technology and refrigeration from the Southern Technical Institute, a branch of Georgia Tech (now known as Southern Polytechnic Institute). He taught HVAC classes at Coosa Valley Vocational & Technical Institute for four years. He moved on to become service manager for Layne Trane, Charlotte, N.C. He taught for 15 years at Central Piedmont Community College, part of this time as program director. He had his own business for five years doing installation and service work. Now retired, he is the author of Practical Heating Technology and Practical Cooling Technology, and continues as a co-author of Refrigeration & Air Conditioning Technology, seventh edition, all published by Delmar Cengage Learning. For more information, he can be reached at 704-968-0000 or thebillj1@gmail.com.

Btu Buddy Notebook is a collection of more than 50 service call scenarios in book form covering both cooling season and heating season troubleshooting. For more information and to purchase the book, visit the HVACR Industry Store.

Recommended Content

JOIN TODAY
To unlock your recommendations.

Already have an account? Sign In

  • HVAC-enrollment

    The Trades Are Back: HVACR Programs See Nearly 30% Enrollment Spike

    A new wave of future technicians is entering the pipeline.  
    News
    By: Matt Jachman
  • 2025 Top 40 Under 40

    2025 Top 40 Under 40 HVACR Professionals List

    The 11th annual Top 40 Under 40 list highlights those...
    HVAC Residential Market
    By: Hannah Belloli-Oster
  • LG Ductless Mini-Split Systems

    The 9 Types of Heat Pumps

    As the U.S. moves toward electrification, heat pumps are...
    Ground Source Heat Pumps
    By: Joanna R. Turpin
Subscription Center
  • Create an Account
  • Start a Subscription
  • Manage My Account
  • Sign Up for Newsletters
  • Visit Customer Service
  • Update Preferences

More Videos

Sponsored Content

Sponsored Content is a special paid section where industry companies provide high quality, objective, non-commercial content around topics of interest to The News audience. All Sponsored Content is supplied by the advertising company and any opinions expressed in this article are those of the author and not necessarily reflect the views of The News or its parent company, BNP Media. Interested in participating in our Sponsored Content section? Contact your local rep!

close
  • Piggy Bank
    Sponsored byWatercress Financial

    Energy Prices, Inflation, and HVAC: What Today’s Homeowners Care About

  • Refrigerated Food
    Sponsored bySolstice Advanced Materials

    R-455A Refrigeration: A Cold Storage Solution for the Future

  • Airex Rooftop Units
    Sponsored byAirex Manufacturing Inc

    Consolidating Roof Penetrations: A Growing Trend in Multifamily HVAC Design

Popular Stories

HVAC-Price-Increase-graphic

HVAC Price Increase List: June 2026

Trump-Section-232.jpg

Trump Reduces Section 232 Tariffs on HVAC Equipment to 15%

R410A-Refrigerant-Cylinder.jpg

Refrigerant Recovery is a Revenue Opportunity

Heat-pump-cutaway.jpg

PFAS Rules and A2L Building Codes Continue to Evolve

Midea-training.jpg

HVAC Workforce Crisis Expands Beyond Technicians to Instructor Shortages

View The ACHR NEWS
Centennial Anniversary Timeline

The ACHR News Timeline Chart
Submit a Letter
Submit a letter to our editors.

Events

November 6, 2025

Next-Gen Data Center Cooling: HVAC Innovation and Real-World Solutions

On Demand As AI workloads and high-density computing push traditional cooling methods to their limits, the data center industry is accelerating the adoption of next-generation HVAC technologies.

June 17, 2026

Decarbonization Without Disruption

This webinar will explore practical HVAC decarbonization strategies that minimize disruption while maximizing long-term performance and ROI.

View All Submit An Event

Poll

Summer Staff

Are you fully staffed for the summer season?
View Results Poll Archive

Products

BNI Mechanical/Electrical Square Foot Costbook, 2026 Edition

BNI Mechanical/Electrical Square Foot Costbook, 2026 Edition

See More Products
Decarbonization Without Disruption - Free Webinar - 6/17/2026

Related Articles

  • a typical condensing furnace vent termination

    Btu Buddy 162: A Furnace That Won’t Vent

    See More
  • Btu Buddy 76: Condenser Fan Motor Problems

    See More
  • Fig 1

    Btu Buddy 175: Control Wiring Problems

    See More

Related Products

See More Products
  • Evaluating-and-Troubleshooting-Refrigeration-Systems-Video-Cover-210x300.jpg

    Evaluating Refrigeration Systems Troubleshooting & Identifying Problems CONTINUED

See More Products

Events

View AllSubmit An Event
  • July 16, 2025

    Let’s Talk: Condensing Equipment, (Acidic) Condensate, and the Code

    On Demand During this webinar, we will define what acidic condensate is, illustrate how it’s formed in today’s high-efficiency, gas-fired heating appliances, and hit on the damage it can cause if not treated.
View AllSubmit An Event

Related Directories

  • Condenser and Chiller Services

    Offers in-field eddy current inspection, remote video inspection, protective epoxy coatings and complete retubing service with tubes in stock.
×

Sign Up. Stay Informed.

The #1 trusted source for the HVACR industry since 1926

SUBSCRIBE
  • RESOURCES
    • Advertise
    • Contact Us
    • Advisory Board
    • Classifieds
    • Submit a Letter
    • Directories
    • Store
  • ACCOUNT CENTER
    • Create an Account
    • Start a Subscription
    • Manage My Account
    • Sign Up for Newsletters
    • Visit Customer Service
    • Update Preferences
  • SERVICES
    • Marketing Services
    • Reprints
    • Market Research
    • List Rental
    • Survey/Respondent Access
  • STAY CONNECTED
    • LinkedIn
    • Facebook
    • Instagram
    • YouTube
    • X (Twitter)
  • PRIVACY
    • PRIVACY POLICY
    • TERMS & CONDITIONS
    • DO NOT SELL MY PERSONAL INFORMATION
    • PRIVACY REQUEST
    • ACCESSIBILITY

Copyright ©2026. All Rights Reserved BNP Media, Inc. and BNP Media II, LLC.

Design, CMS, Hosting & Web Development :: ePublishing