ACHR News
search
Ask ACHR NEWS AI
cart
facebook twitter instagram linkedin youtube
  • Sign In
  • Subscribe
  • Sign Out
  • My Account
ACHR News
  • NEWS
    • Breaking News
    • New HVAC Products
    • Featured Products
    • Manufacturer Reports
    • HVAC Data
    • Legislation
    • ACHR NEWS Centennial
  • RESIDENTIAL
    • Air Conditioners
    • Furnaces
    • Residential Heat Pumps
    • Ductless
    • Residential IAQ
    • Testing, Monitoring, Tools
    • Components & Accessories
  • COMMERCIAL
    • Air Handlers
    • Rooftop Units
    • Chillers and Cooling Towers
    • Commercial Heat Pumps
    • Boilers and Hydronics
    • VRF/Ductless
    • Commercial IAQ
  • REFRIGERATION
    • Refrigerants
    • Refrigerant Regulations
    • Leak Management
  • CONTRACTOR PRO
    • Geothermal
    • Homeowner Study
    • VRF and VRV Ductless
    • Unitary Trends
  • EDUCATION
    • Training and Education
    • Business Management
    • Service and Maintenance
    • Continuing Education
    • Market Research >
      • HVAC Brand Awareness Report
      • VRV, VRF, VRVZ Report
      • Unitary Trends Report
      • Water Heat Professionals Report
    • Webinars
    • Sponsor Insights
    • eProducts Info
    • White Papers
  • EVENTS
    • HVAC Contractor Forum
    • Industry Events and Webinars
  • MEDIA
    • Videos
    • AHR Expo 2025 Videos
    • Podcasts >
      • ACHR News Podcast
      • HARDI Podcasts
      • AHR Expo Podcasts
      • ACCA Podcasts
    • Interactive Spotlights
    • Quizzes
    • eBooks
    • HVAC Talkback
  • HVAC GROUP
    • ACHR NEWS >
      • Current Issue
      • Digital Edition
      • Subscribe
    • Distribution Trends
    • SNIPS NEWS >
      • Join SNIPS NEWS
    • Engineered Systems News >
      • Join ES News
    • HVACR Directory
    • Contests
    • Newsletters
    • Contact
    • Advertise
    • My Account
RefrigerationIce Machines

The Professor: Ice Flake Machine Troubleshooting

By John Tomczyk
February 7, 2011
Figure 1. A cutting edge, or flight, is shown to the right in this photo of an auger. (Courtesy of Ferris State University.)

This article is part one of a two-part series on ice flake machine troubleshooting. This article will examine troubleshooting low and high water levels. Next month’s article will examine water impurities and mechanical problems.

Many ice flake machines employ an auger rotating within an insulated freezing cylinder or evaporator. The auger, which is driven and geared down by a gear motor and gear box to about 8-16 rpm, has cutting edges or flights. The flights shave ice from the walls of the freezing cylinder (evaporator) which is flooded with water and has refrigerant lines wrapped around its outer circumference (Figure 1). The refrigerant lines have vaporizing refrigerant in them which will freeze the water that is in close proximity or contact to the inside of the freezing cylinder.

Figure 2. This schematic shows the relationship of the water level with the freezing cylinder in a flake ice machine. (Courtesy of Hoshizaki America.)

A water reservoir supplies the right height or level of water to the freezing cylinder.

Because water will seek its own level, the water level or height in the water reservoir will also be the level in the freezing cylinder (Figure 2). Water level in the reservoir is usually controlled by a single float mechanism, or a dual-float mechanism which controls an electric solenoid valve to bring water to the reservoir.

The water-logged shaved ice is then carried through the water to the top or head of the freezing cylinder where it is squeezed, extruded, shaped, cut and eventually falls to an insulated ice storage bin for use (Figure 3).

It is of utmost importance that the water level in the reservoir and freezing cylinder are at the proper levels for the ice flake machine to operate effectively. What follows are some scenarios for improper water levels in the freezing cylinder, and how they affect other components of the ice flake machine.

LOW WATER LEVELS

If a float mechanism in the water reservoir is adjusted wrong and the water level is low in the reservoir, it will also be low in the freezing cylinder because of water seeking its own level. Since water is the refrigerating load for an ice flake machine, low water level in the freezing cylinder means low load on the evaporator. This condition will cause lower than usual evaporator pressures, thus lower evaporator temperatures.

These low evaporator temperatures will produce harder and colder ice for the auger to cut. This will put an extra load on the auger, gears, and gear motor. Often, the gear motor will trip on its overload and sometimes has to be manually reset. Water reservoirs should have a line indicating the correct water level for that particular machine.

Figure 3. Water-logged shaved ice is carried through the water to the top or head of the freezing cylinder where it is squeezed, extruded, shaped, cut and eventually falls to an insulated ice storage bin for use. (Courtesy of Ferris State University.)

HIGH WATER LEVELS

If the float mechanism in the water reservoir is adjusted wrong, or the seat in the float chamber is leaking and the water level is too high, the freezing cylinder will experience high water levels. This will cause stress on the gear motor from the auger doing more work because there is more surface area of ice to cut.

Again, the overload may trip on the gear motor. When the gear motor’s overload reset button must be reset often, a service technician should suspect water level problems as a possible cause. Often, high water levels will cause water to pour over into the ice storage bin and cause a large melting depression in the stored flaked ice. Also, this new water constantly coming into the freezing cylinder will impose extra heat load on the evaporator and cause higher than normal evaporating pressures and poor ice quality and quantity. This happens because the higher quantities of new water will have to be refrigerated to the freezing point to start making ice.

Publication date: 02/07/2011
KEYWORDS: maintenance for HVACR troubleshooting and HVACR

Share This Story

Looking for a reprint of this article?
From high-res PDFs to custom plaques, order your copy today!

 

John Tomczyk is HVACR professor emeritus, Ferris State University, Big Rapids, Michigan, and coauthor of Refrigeration & Air Conditioning Technology, published by Cengage Learning. Contact him at tomczykjohn@gmail.com.

Recommended Content

JOIN TODAY
To unlock your recommendations.

Already have an account? Sign In

  • HVAC-enrollment

    The Trades Are Back: HVACR Programs See Nearly 30% Enrollment Spike

    A new wave of future technicians is entering the pipeline.  
    News
    By: Matt Jachman
  • 2025 Top 40 Under 40

    2025 Top 40 Under 40 HVACR Professionals List

    The 11th annual Top 40 Under 40 list highlights those...
    HVAC Residential Market
    By: Hannah Belloli-Oster
  • LG Ductless Mini-Split Systems

    The 9 Types of Heat Pumps

    As the U.S. moves toward electrification, heat pumps are...
    HVAC Residential Market
    By: Joanna R. Turpin
Subscription Center
  • Create an Account
  • Start a Subscription
  • Manage My Account
  • Sign Up for Newsletters
  • Visit Customer Service
  • Update Preferences

More Videos

Sponsored Content

Sponsored Content is a special paid section where industry companies provide high quality, objective, non-commercial content around topics of interest to The News audience. All Sponsored Content is supplied by the advertising company and any opinions expressed in this article are those of the author and not necessarily reflect the views of The News or its parent company, BNP Media. Interested in participating in our Sponsored Content section? Contact your local rep!

close
  • Piggy Bank
    Sponsored byWatercress Financial

    Energy Prices, Inflation, and HVAC: What Today’s Homeowners Care About

  • Refrigerated Food
    Sponsored bySolstice Advanced Materials

    R-455A Refrigeration: A Cold Storage Solution for the Future

  • Airex Rooftop Units
    Sponsored byAirex Manufacturing Inc

    Consolidating Roof Penetrations: A Growing Trend in Multifamily HVAC Design

Popular Stories

Refrigerants-and-gauge.jpg

HVAC Industry Warns of Counterfeit Refrigerants Entering U.S. Supply Chain

U.S. Supreme Court building

95% Furnace Efficiency Rule to Get New Hearing

Data_Center_facility.jpg

HVAC Manufacturers Respond to Growing Data Center Backlash

Midea-training.jpg

HVAC Workforce Crisis Expands Beyond Technicians to Instructor Shortages

HVAC Minute retail refrigeration system

EPA Final Rule’s Impact on R-410A Deadlines

View The ACHR NEWS
Centennial Anniversary Timeline

The ACHR News Timeline Chart
Submit a Letter
Submit a letter to our editors.

Events

November 6, 2025

Next-Gen Data Center Cooling: HVAC Innovation and Real-World Solutions

On Demand As AI workloads and high-density computing push traditional cooling methods to their limits, the data center industry is accelerating the adoption of next-generation HVAC technologies.

June 23, 2026

HVAC Duct Sealing Mastics: Why Selection Matters

In this webinar we will detail what HVAC material buyers and technicians need to know when selecting duct mastics, including matching mastic to substrate, alternatives to liquid mastic, and where UL 181 Listings fit into real world installations.

View All Submit An Event

Poll

Summer Staff

Are you fully staffed for the summer season?
View Results Poll Archive

Products

BNI Mechanical/Electrical Square Foot Costbook, 2026 Edition

BNI Mechanical/Electrical Square Foot Costbook, 2026 Edition

See More Products
HVAC Duct Sealing Mastics: Why Selection Matters - Free Webinar - 6/23/2026

Related Articles

  • The Professor: More Ice Flake Machine Troubleshooting

    See More
  • Manitowoc Ice, Inc.: Flake Ice Machine

    See More
  • The Professor: Ice Machine Control Schemes

    See More

Related Products

See More Products
  • Uncomplicating The Heat Pump: Electrical System Troubleshooting DVD

  • Troubleshooting Tips for Servicing Refrigeration Systems

  • HVACR Troubleshooting Fundamentals  Electrical Book Cover Image.jpg

    HVACR Troubleshooting Fundamentals: Electricity and Wiring Diagrams

See More Products
×

Sign Up. Stay Informed.

The #1 trusted source for the HVACR industry since 1926

SUBSCRIBE
  • RESOURCES
    • Advertise
    • Contact Us
    • Advisory Board
    • Classifieds
    • Submit a Letter
    • Directories
    • Store
  • ACCOUNT CENTER
    • Create an Account
    • Start a Subscription
    • Manage My Account
    • Sign Up for Newsletters
    • Visit Customer Service
    • Update Preferences
  • SERVICES
    • Marketing Services
    • Reprints
    • Market Research
    • List Rental
    • Survey/Respondent Access
  • STAY CONNECTED
    • LinkedIn
    • Facebook
    • Instagram
    • YouTube
    • X (Twitter)
  • PRIVACY
    • PRIVACY POLICY
    • TERMS & CONDITIONS
    • DO NOT SELL MY PERSONAL INFORMATION
    • PRIVACY REQUEST
    • ACCESSIBILITY

Copyright ©2026. All Rights Reserved BNP Media, Inc. and BNP Media II, LLC.

Design, CMS, Hosting & Web Development :: ePublishing