ACHR News
search
Ask ACHR NEWS AI
cart
facebook twitter instagram linkedin youtube
  • Sign In
  • Subscribe
  • Sign Out
  • My Account
ACHR News
  • NEWS
    • Breaking News
    • New HVAC Products
    • Featured Products
    • Manufacturer Reports
    • HVAC Data
    • Legislation
    • ACHR NEWS Centennial
  • RESIDENTIAL
    • Air Conditioners
    • Furnaces
    • Residential Heat Pumps
    • Ductless
    • Residential IAQ
    • Testing, Monitoring, Tools
    • Components & Accessories
  • COMMERCIAL
    • Air Handlers
    • Rooftop Units
    • Chillers and Cooling Towers
    • Commercial Heat Pumps
    • Boilers and Hydronics
    • VRF/Ductless
    • Commercial IAQ
  • REFRIGERATION
    • Refrigerants
    • Refrigerant Regulations
    • Leak Management
  • CONTRACTOR PRO
    • Geothermal
    • Homeowner Study
    • VRF and VRV Ductless
    • Unitary Trends
  • EDUCATION
    • Training and Education
    • Business Management
    • Service and Maintenance
    • Continuing Education
    • Market Research >
      • HVAC Brand Awareness Report
      • VRV, VRF, VRVZ Report
      • Unitary Trends Report
      • Water Heat Professionals Report
    • Webinars
    • Sponsor Insights
    • eProducts Info
    • White Papers
  • EVENTS
    • HVAC Contractor Forum
    • Industry Events and Webinars
  • MEDIA
    • Videos
    • AHR Expo 2025 Videos
    • Podcasts >
      • ACHR News Podcast
      • HARDI Podcasts
      • AHR Expo Podcasts
      • ACCA Podcasts
    • Interactive Spotlights
    • Quizzes
    • eBooks
    • HVAC Talkback
  • HVAC GROUP
    • ACHR NEWS >
      • Current Issue
      • Digital Edition
      • Subscribe
    • Distribution Trends
    • SNIPS NEWS >
      • Join SNIPS NEWS
    • Engineered Systems News >
      • Join ES News
    • HVACR Directory
    • Contests
    • Newsletters
    • Contact
    • Advertise
    • My Account

Service Hotline: 01/01/2002

By Peter Powell
December 22, 2001

R-408A

QUESTION:
Karim Machiwalla
Atlanta, GA

I came across an ice cream cake display freezer. The system was retrofitted with R-408A by some technician. But the system did not work.

When I checked the system’s operating pressure, I found the head pressure at 250 psi, back pressure at 10 psi at –10 degrees F, and cabinet temperature at an ambient 65 degrees.

What really happens is when the cabinet temperature goes below –10 degrees, the back pressure goes into vacuum, and the system cycles on the low-pressure switch.

Since I could not find a pressure-temperature chart for 408A, I could not check the superheat of the system. I was wondering if 408A is the right refrigerant for this kind of application. If yes, then I could not understand why the back pressure is so low. I checked the piping for blocking. It seems to be all right. Also, there is no moisture problem.

ANSWER:
From Gus Rolotti
Technical Manager
Atofina Chemicals Inc.
Philadelphia, PA

I am assuming that the system was originally an R-502 system that was properly retrofitted to R-408A, but had stopped working prior to your servicing it.

First of all, you asked if you are using the right refrigerant. If the system was originally designed to operate with R-502, then R-408A is the right refrigerant for the application. If the system was not originally designed for use with R-502, then you need to ensure that the proper conversion was made. If not, you can either convert properly or switch to the correct refrigerant. You should be able to determine all this based on the nameplate on the compressor and/or system and, hopefully, on the retrofit information labels. Incidentally, I cannot emphasize enough how important these informational labels are for the future service of the system, either by you or any other technician.

Looking for quick answers on air conditioning, heating and refrigeration topics? Try Ask ACHR NEWS, our new smart AI search tool. Ask ACHR NEWS →

If your cabinet temperature was –10 degrees, then your coil should be at least –10 degrees or colder. From the pressure-temperature saturation charts, you can see that the corresponding pressure is approximately 20 psig and not the 10 psig you measured. The corresponding temperature for the 10 psig you measured is about –25 degrees.

Since this is not what you have, you probably have either an obstruction in one of your lines or filters (debris, etc.), your TXV could be undersized, or you are low on charge.

An important tool in troubleshooting your system would be to measure its superheat. You said you did not have a pressure-temperature chart. You can obtain one through your refrigerant supplier, or you can download one from our website at www.forane.com.

No Data Plate

COMMENT:
From Brett Potter
Journeyman Mechanic
Sierra Refrigeration
Fresno, CA

I want to offer some additional comments to the questions dealing with charging systems with no data plate that appeared in the Jan. 8 and May 14 issues of The News.

Just because a system has a sight glass, it should not be a direct indication of charge until the glass is full. Using 10 degrees to 15 degrees suction superheat is a good general rule as measured at the compressor service valve. Low-temp systems can run suction superheats as high as 50 degrees.

In addition, liquid subcooling is just as important as superheat when “blindly” charging a system.

Superheat is important in maintaining compressor longevity and proper motor cooling. However, to focus only on superheat when charging a system that you have no idea what the weighed charge should be, could be asking for trouble.

Most important is to determine whether or not the system requires a critical charge. Systems that utilize a TXV metering device and a liquid receiver can usually charge to a full glass and 99% of the time will be trouble free as long as no other system problems are present.

This will not always hold true for the replacement refrigerants that we are seeing these days and on some special applications. But let’s assume a standard R-22 air conditioning application. Critical-charge systems require a little more investigating on the tech’s part as to what method he should use to charge the system. The tech should determine the refrigerant and the type of metering device if not known.

For example, a system that uses a fixed orifice to meter the refrigerant flow to the evaporator would require a superheat-type charging method to obtain a correct charge. Any fixed metering device is relying solely on the pressure differential across it to determine its flow rate. For this reason, evaporator load, suction superheat, and ambient temps become critical in determining the proper charge.

However, the same system that has a TXV should be charged using a subcooling method to obtain both the proper charge and the maximum evaporator efficiency. Of course, this does not mean you should ignore the suction superheat when charging a TXV system. This metering device has the ability to throttle the refrigerant flow in an attempt to maintain its set superheat value. It requires only quality liquid from the condenser and it takes care of the rest, based on the evaporator load.

It is quite common to see a system that is fully charged, but at the same time has poor evaporator performance and poor superheat due to a faulty metering device. Attempting to charge this system based only on a superheat reading would never work. If you were able to get the superheat anywhere near 10 degrees, the system would more than likely be way overcharged.

Obtaining the saturated condensing temperature and the amount of liquid subcooling when charging confirms that you have quality liquid refrigerant, as well as giving the technicians a baseline to work from.

To attempt to achieve a 100% efficient evaporator with a lower superheat adjustment is silly. First off, there is no such thing as a 100% efficient evaporator because of the flash gas that occurs during initial expansion at the evaporator inlet. Lowering the superheat setting on the TXV will not reduce the amount of flash gas. Subcooling the liquid, however, will reduce flash gas at the TXV, and allow the efficiency of the evaporator to rise without lowering the superheat. Given the same load on two evap coils — with 0 degrees subcooling and 10 degrees suction superheat — it will be less efficient than that having 10 degrees of subcooling with the same superheat.

Also, “X” degrees of superheat is X degrees no matter how long the line is. Yes, long line runs tend to pick up some extra superheat. But I would be more inclined to pay attention to line sizing and piping practices to maintain compressor life in long suction lines.

There is no question that superheat is important when charging a system. But subcooling is something that also should always be checked when charging and/or determining the performance of any system — data plate or not.

Brazing Help

COMMENT:
By Gary Bass
General Manager
American Lokring Corp.
Winter Haven, FL

I want to offer some additional assistance to the writer of a question on brazing that appeared in the June 4, 2001 issue of The News. I would suggest checking out the website www.lokringusa.com for more assistance in this area.

With the new energy restrictions, technicians will see more and more of the aluminum/copper joints.

Publication date: 01/01/2002

Share This Story

Looking for a reprint of this article?
From high-res PDFs to custom plaques, order your copy today!

 

Peter Powell is Refrigeration Editor. He can be contacted at 815-654-7270 or peterpowell@achrnews.com. Peter was formerly Editor/Publisher of Service & Contracting, where he gained his refrigeration experience. Among his duties, Powell is responsible for the monthly Refrigeration Zone sections in The NEWS

Recommended Content

JOIN TODAY
To unlock your recommendations.

Already have an account? Sign In

  • HVAC-enrollment

    The Trades Are Back: HVACR Programs See Nearly 30% Enrollment Spike

    A new wave of future technicians is entering the pipeline.  
    News
    By: Matt Jachman
  • 2025 Top 40 Under 40

    2025 Top 40 Under 40 HVACR Professionals List

    The 11th annual Top 40 Under 40 list highlights those...
    News
    By: Hannah Belloli-Oster
  • LG Ductless Mini-Split Systems

    The 9 Types of Heat Pumps

    As the U.S. moves toward electrification, heat pumps are...
    HVAC Residential Market
    By: Joanna R. Turpin
Subscription Center
  • Create an Account
  • Start a Subscription
  • Manage My Account
  • Sign Up for Newsletters
  • Visit Customer Service
  • Update Preferences

More Videos

Sponsored Content

Sponsored Content is a special paid section where industry companies provide high quality, objective, non-commercial content around topics of interest to The News audience. All Sponsored Content is supplied by the advertising company and any opinions expressed in this article are those of the author and not necessarily reflect the views of The News or its parent company, BNP Media. Interested in participating in our Sponsored Content section? Contact your local rep!

close
  • Piggy Bank
    Sponsored byWatercress Financial

    Energy Prices, Inflation, and HVAC: What Today’s Homeowners Care About

  • Refrigerated Food
    Sponsored bySolstice Advanced Materials

    R-455A Refrigeration: A Cold Storage Solution for the Future

  • Airex Rooftop Units
    Sponsored byAirex Manufacturing Inc

    Consolidating Roof Penetrations: A Growing Trend in Multifamily HVAC Design

Popular Stories

HVAC-Price-Increase-graphic

HVAC Price Increase List: June 2026

Trump-Section-232.jpg

Trump Reduces Section 232 Tariffs on HVAC Equipment to 15%

R410A-Refrigerant-Cylinder.jpg

Refrigerant Recovery is a Revenue Opportunity

Heat-pump-cutaway.jpg

PFAS Rules and A2L Building Codes Continue to Evolve

Kroger.jpg

Kroger to Spend $100 Million to Reduce Refrigerant Leaks

View The ACHR NEWS
Centennial Anniversary Timeline

The ACHR News Timeline Chart
Submit a Letter
Submit a letter to our editors.

Events

November 6, 2025

Next-Gen Data Center Cooling: HVAC Innovation and Real-World Solutions

On Demand As AI workloads and high-density computing push traditional cooling methods to their limits, the data center industry is accelerating the adoption of next-generation HVAC technologies.

June 17, 2026

Decarbonization Without Disruption

This webinar will explore practical HVAC decarbonization strategies that minimize disruption while maximizing long-term performance and ROI.

View All Submit An Event

Poll

Summer Staff

Are you fully staffed for the summer season?
View Results Poll Archive

Products

BNI Mechanical/Electrical Square Foot Costbook, 2026 Edition

BNI Mechanical/Electrical Square Foot Costbook, 2026 Edition

See More Products
Decarbonization Without Disruption - Free Webinar - 6/17/2026

Related Articles

  • Service Hotline - 01/08/2001: Charge It and Wet Systems

    See More
  • Service Hotline: 10/01/2001

    See More
  • Service Hotline: 03/04/2002

    See More

Related Products

See More Products
  • ac.png

    Air Conditioning Service Guide R-410A and R-22 Systems 2nd Edition

  • HPOIS.png

    Heat Pump Operation, Installation, Service

  • Service-Management-Excellence-Image-2A.jpg

    Service Management Excellence

See More Products

Related Directories

  • Service Logic

    Headquartered in Charlotte, Service Logic is the largest privately held HVAC company, with more than 120 locations, in the US and Canada. Our HVAC services optimize energy efficiency, comfort, productivity, health and safety.
×

Sign Up. Stay Informed.

The #1 trusted source for the HVACR industry since 1926

SUBSCRIBE
  • RESOURCES
    • Advertise
    • Contact Us
    • Advisory Board
    • Classifieds
    • Submit a Letter
    • Directories
    • Store
  • ACCOUNT CENTER
    • Create an Account
    • Start a Subscription
    • Manage My Account
    • Sign Up for Newsletters
    • Visit Customer Service
    • Update Preferences
  • SERVICES
    • Marketing Services
    • Reprints
    • Market Research
    • List Rental
    • Survey/Respondent Access
  • STAY CONNECTED
    • LinkedIn
    • Facebook
    • Instagram
    • YouTube
    • X (Twitter)
  • PRIVACY
    • PRIVACY POLICY
    • TERMS & CONDITIONS
    • DO NOT SELL MY PERSONAL INFORMATION
    • PRIVACY REQUEST
    • ACCESSIBILITY

Copyright ©2026. All Rights Reserved BNP Media, Inc. and BNP Media II, LLC.

Design, CMS, Hosting & Web Development :: ePublishing