Determining a System's Btu Capacity

Many field-assembled refrigeration systems require the installing contractor or sales engineer to select the system components. This involves choosing the correct condensing unit (compressor), unit cooler (evaporator), metering device, refrigerant, accessories, and piping.

Before any of the system components can be selected, however, the required Btu capacity of the system must be determined. This is accomplished by performing a heat load calculation.

The required Btu capacity is the baseline for selecting the proper components for any installation. Many of the major system components are selected based on the Btu capacity of the system.

After determining the required Btu capacity, the sales engineer or installing contractor will choose the type of refrigerant to use in the system. Today, R-134a is popular for medium-temperature applications; R-404A is popular for low-temperature applications.

FIRST THINGS FIRST

Normally, the first major system component selected is the condensing unit, or the compressor if the system will have a remote condenser. The Btu capacity of any compressor or condensing unit is based on the suction pressure of the refrigerant entering the compressor.

Because of this, most manufacturers will provide the Btu capacity of their compressors or condensing units at a specific entering suction pressure; in particular, at a specific saturation temperature. The saturation temperature of the refrigerant is obtained by using a standard pressure-temperature (P-T) chart and converting the suction pressure to its equivalent saturation temperature.

For example, if R-134a were the refrigerant and the entering suction pressure was 18.5 psig, the corresponding saturation temperature entering the compressor would be 20°F. To determine the saturation temperature of refrigerant entering a compressor, the design evaporator temperature must first be determined.

Many standard medium-temperature applications are designed around an evaporator temperature of 20° to 25°. Many low-temperature applications are designed around an evaporating temperature of -10°.

Once the design evaporator temperature is determined, subtract any suction line pressure losses to determine the approximated saturation temperature at the inlet of the compressor. A pressure loss equivalent to a 2° reduction in saturation temperature is used for most applications (e.g., if the design evaporating temperature were 22°, the assumed saturation temperature entering the compressor would be 20°).

NEXT SELECTIONS

The next component selected is the unit cooler or evaporator. The unit cooler must closely match the design Btu capacity of the compressor or condensing unit. Manufacturers of unit coolers will provide Btu capacity at a specific temperature difference (TD: the difference between the air entering the unit cooler and the evaporating temperature of the refrigerant leaving the unit cooler).

The desired TD of the unit cooler is selected to match the humidity requirements of the product being stored. A TD of 10° is normally used for storage of general packaged products at 85 percent rh. Other types of products may require different relative humidity conditions; this will change the design TD.

Once the unit cooler has been selected, the metering device is next. Most field-installed systems use a thermostatic or electronic expansion valve. Capillary tubes and automatic expansion valves are normally used on self-contained systems, which are completely assembled at the factory.

The thermostatic expansion valve (TXV) is also selected based on the system's Btu capacity, both the capacity of the condensing unit and the unit cooler. The capacity of a TXV is based on several system characteristics. Always follow the TXV manufacturer's selection guidelines.

LINE SIZE

Once all the major system components have been chosen, the line size for the ACR tubing is selected. The size of the tubing is also based on the Btu capacity of the system, as well as the length of run.

It is important to use correctly sized suction, discharge, and liquid lines on any application. Using too small of a suction line will reduce the overall system capacity. Using a suction line that's too large may lead to oil return problems.

Always follow the equipment component manufacturer's guidelines for selecting the correct line sizes.

Selecting the correct components for a refrigeration system is not difficult as long as the installing contractor understands the basic principles of the selection process.

Publication date: 08/07/2006

Joe Marchese is an author and instructor and former HVACR contractor. He can be reached at joe@reachtechnicaltraining.com.

Recent Articles by Joe Marchese

You must register or login in order to post comments.

Multimedia

Videos

Image Galleries

2012 ACCA Conference & Indoor Air Expo

Highlights from the 2012 ACCA Conference & Indoor Air Expo in Las Vegas.

Podcasts

NEWSMakers: Doyle James
Angela Harris sat down with Doyle James, president of Aire Serv to discuss the ins and outs of franchising. Whether you are looking for a franchise opportunity or are content with the way things are, this man has some business tips for every HVAC contractor.
More Podcasts

THE MAGAZINE

ACHRNEWS

NEWS 05-21-12 cover

2012 May 21

Check out the weekly edition of The NEWS today!

TABLE OF CONTENTS SUBSCRIBE

Energy management

Do you think home energy management will gain traction in the residential market?
See Poll Results Poll Archive

HVACR INDUSTRY STORE

prof-reference-master-ed-2.gif
DEWALT HVAC/R Professional Reference Master Edition

With more than 500 pages of extensive information on such important topics as refrigeration systems, piping, ductwork, motors, compressors, fans, pumps and more, this "answer book" is one of the most complete HVAC/R professional references available.

More Products

Clear Seas Research

Clear Seas ResearchWith access to over one million professionals and more than 60 industry-specific publications, Clear Seas Research offers relevant insights from those who know your industry best. Let us customize a market research solution that exceeds your marketing goals.

DON'T MISS A THING

Magazine image
 
Register today for complete access to ACHRNews.com. Get full access to the latest features, Extra Edition, and more.

STAY CONNECTED

Facebook Twitter  Linkedin  YouTube logo