ACHR News
search
Ask ACHR NEWS AI
cart
facebook twitter instagram linkedin youtube
  • Sign In
  • Subscribe
  • Sign Out
  • My Account
ACHR News
  • NEWS
    • Breaking News
    • New HVAC Products
    • Featured Products
    • Manufacturer Reports
    • HVAC Data
    • Legislation
    • ACHR NEWS Centennial
  • RESIDENTIAL
    • Air Conditioners
    • Furnaces
    • Residential Heat Pumps
    • Ductless
    • Residential IAQ
    • Testing, Monitoring, Tools
    • Components & Accessories
  • COMMERCIAL
    • Air Handlers
    • Rooftop Units
    • Chillers and Cooling Towers
    • Commercial Heat Pumps
    • Boilers and Hydronics
    • VRF/Ductless
    • Commercial IAQ
  • REFRIGERATION
    • Refrigerants
    • Refrigerant Regulations
    • Leak Management
  • CONTRACTOR PRO
    • Geothermal
    • Homeowner Study
    • VRF and VRV Ductless
    • Unitary Trends
  • EDUCATION
    • Training and Education
    • Business Management
    • Service and Maintenance
    • Continuing Education
    • Market Research >
      • HVAC Brand Awareness Report
      • VRV, VRF, VRVZ Report
      • Unitary Trends Report
      • Water Heat Professionals Report
    • Webinars
    • Sponsor Insights
    • eProducts Info
    • White Papers
  • EVENTS
    • HVAC Contractor Forum
    • Industry Events and Webinars
  • MEDIA
    • Videos
    • AHR Expo 2025 Videos
    • Podcasts >
      • ACHR News Podcast
      • HARDI Podcasts
      • AHR Expo Podcasts
      • ACCA Podcasts
    • Interactive Spotlights
    • Quizzes
    • eBooks
    • HVAC Talkback
  • HVAC GROUP
    • ACHR NEWS >
      • Current Issue
      • Digital Edition
      • Subscribe
    • Distribution Trends
    • SNIPS NEWS >
      • Join SNIPS NEWS
    • Engineered Systems News >
      • Join ES News
    • HVACR Directory
    • Contests
    • Newsletters
    • Contact
    • Advertise
    • My Account
HVAC ContractingTechnical

The Impact of Air Duct Leakage

April 21, 2008

INTRODUCTION

Air duct leakage should be a concern to both the designer and the building owner because of its potential impact on initial construction costs, energy usage, and system performance.

Every duct system requires power. Power drives the fan or blower unit needed to move the air over or through the resistance elements and power operates the compressor or heating elements depending on the desired function. No matter the size, the total benefit of the duct system is based and measured on the peak fan efficiency for that system.

BACKGROUND

Small commercial buildings typically use a packaged air-handling unit where all of the supply and return air ductwork is in the conditioned space. If the design airflows are not properly delivered to the building HVAC loads, the occupants will respond with corresponding higher or lower temperature settings to meet their comfort requirements. The end result is higher energy costs.

In large complex buildings, particularly those with variable air volume systems (VAV), recent research has found that a more complex interaction occurs which requires computer simulation to quantify the energy impact. The Public Interest Energy Research Program (PIER) reported, “… when conditioned air leaks from the supply ducts, the heating or cooling energy associated with leakage heats or cools the return air and changes its temperature (and enthalpy).”1

Typically “…one third of the total annual energy consumption is related to HVAC (heating, ventilation, and cooling). In addition, 39 percent of this HVAC consumption is associated with fan operation.”2

DUCTWORK

The key elements influencing ductwork leakage start with the very basics - size, shape, and construction materials. Ductwork is made from a wide range of materials - galvanized steel, carbon steel, aluminum, stainless steel, fiberglass, polyvinyl chloride (PVC), polyvinyl steel (PVS), duct board, and others. Perhaps the most common material used is galvanized steel. Ductwork is available in rectangular, round, and flat oval geometric shapes. The particular shape that is selected for a specific system should adhere to minimizing the initial installed cost and annual operating costs, as well as conform to the constraints of the building envelope.

There are many reasons why the Sheet Metal and Air Conditioning Contractors’ National Association (SMACNA) HVAC Systems Duct Design Manual recommends the following:

1. Use the minimum number of fittings;

2. Consider the use of semi-extended plenums;

3. Seal ductwork to minimize air leakage;

4. Consider using round duct; and

5. When using rectangular ductwork, maintain an aspect ratio as close to 1-to-1 as possible.

There are several reasons for specifying round ductwork versus rectangular ductwork:

1. Lowest possible duct friction loss for a given perimeter;

2. Lowest weight based upon the same airflows, pressures, and friction loss rates;

3. Requires less supports per running foot;

4. Handles negative pressures with less weight and reinforcement;

5. Handles higher air velocities than rectangular ductwork while achieving the same acoustic design criteria6; and

6. Least expensive to seal for air leakage.

DUCTWORK SEALING

The engineering community has traditionally specified SMACNA’s three distinct duct sealing classes (A, B, or C), which differ in their requirements for sealing the transverse joint, longitudinal seams, and duct penetrations. Typically the designer will specify a Seal Class and a percentage of the design airflow as an acceptable air leakage rate.

As reported in the SMACNA 1990 HVAC Systems Duct Design Manual, duct leakage previously specified as an arbitrarily established percentage of the airflow was impossible to attain by the installing contractor. Joint research conducted by SMACNA and the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) has since developed a methodology used to relate the amount of ductwork leakage to the ductwork surface area and the design static pressure independent of the actual airflow in the ductwork.

SMACNA publishes a table (Table 1) that correlates the Seal Class (A, B, or C) and the Leakage Class (typically 3, 6, 12, or 48). Obviously, this assumes a superior application of sealants to the ductwork system.

ASHRAE’s Energy Standard 90.1 recognizes the Leakage Class method for

Lmax = CLP0.65

where:
Lmax = maximum permitted leakage in cfm/100 ft2 ductwork surface area
CL = duct leakage class, cfm/100ft2 at 1 inch water gauge
P = test pressure, which shall be equal to the design duct pressure class rating in inches water column

In addition, the leakage class recognizes that under the best conditions, rectangular ductwork will leak air at a rate twice greater than round.

METHODS OF SEALING DUCTWORK

Various recognized methods of sealing ductwork also vary in degrees of cost, quality, visual appearance, and performance. Choices range from various types of flanges, to slip fit connections that require liquids, mastics, tapes, or heat-applied materials to seal the joints. In addition, several ductwork manufacturers offer a factory-applied gasket with self-sealing characteristics that do not require the field application of external sealants. Exposed ductwork remains in vogue with the architectural tastes of both designers and building owners, a trend that requires more attention be paid to the ductwork sealing methods than in the past because of the visual aesthetics.

Click on the table for an enlarged view.

ENERGY COSTS

A typical response to unanticipated ductwork air leakage has been:

1. Increased design airflows which increase the initial construction costs for equipment and ductwork;

2. Increased fan energy;

3. Increased energy for heating, cooling, and dehumidifying the air stream;

4. Increased difficulty in air balancing the system airflows;

5. Impacts on indoor air quality (IAQ); and

6. Compromised occupant comfort.

Computer simulations previously reported through PIER1 and confirmed by actual field measurements found the impact of air duct leakage on the total energy used to condition the occupied space as follows:

• “…the increase in total annual HVAC site energy is 2 percent – 14 percent” and this

• “…includes supply and return fan electricity consumption, chiller and cooling tower electricity consumption, boiler electricity consumption, and boiler natural gas consumption.”

For a less complex constant volume system, the annual increase in energy consumption for the supply fan alone (Table 2) ranges from 4 percent for a Leakage Class 6 system to 101 percent for a Leakage Class 48. Leakage Class 3 is the tightest leakage class currently recognized by SMACNA and ASHRAE. A Leakage Class 48 is what one may expect with unsealed rectangular ductwork and is the highest recognized leakage class. This table represents what would be expected in an actual operating system based upon: changes in the system delivered cfm (CFM2) due to air leakage; revised system total static pressure (TSP2) as calculated using established fan laws; and the actual required fan brake horsepower (BHP2) using the published fan performance data from a nationally recognized fan manufacturer.

CONCLUSIONS

HVAC systems account for upwards of 40 percent of a building’s annual energy usage. High efficiency equipment is one way to reduce annual utility costs; however, understanding the different styles of duct systems and the impact of duct leakage is key to realizing maximum system efficiency.

References

1. The Public Interest Energy Research (PIER) Program, “Duct Leakage Impacts on VAV System Performance in California Large Commercial Buildings,” Contract Number 400-99-012-1, conducted by the Energy Performance of Buildings Group, Environmental Energy Technologies Division of the Lawrence Berkeley National Laboratory (Published October 2003)
2. California Energy Commission Year 2000 Energy Estimates
3. SMACNA HVAC Duct Construction Standards
4. SMACNA HVAC Systems Duct Design
5. ASHRAE 90.1
6. ASHRAE 2003 HVAC Applications Chapter 17 Sound and Vibration Control

Reprinted with permission from Lindab Inc.’s Duct Leakage White Paper. Lindab manufactures spiral ductwork and fittings for indoor climate solutions. For more information, visit www.lindabusa.com.

Publication date: 04/21/2008

Links

  • Lindab Inc.

Share This Story

Looking for a reprint of this article?
From high-res PDFs to custom plaques, order your copy today!

 

Recommended Content

JOIN TODAY
To unlock your recommendations.

Already have an account? Sign In

  • HVAC-enrollment

    The Trades Are Back: HVACR Programs See Nearly 30% Enrollment Spike

    A new wave of future technicians is entering the pipeline.  
    News
    By: Matt Jachman
  • 2025 Top 40 Under 40

    2025 Top 40 Under 40 HVACR Professionals List

    The 11th annual Top 40 Under 40 list highlights those...
    News
    By: Hannah Belloli-Oster
  • LG Ductless Mini-Split Systems

    The 9 Types of Heat Pumps

    As the U.S. moves toward electrification, heat pumps are...
    Air Source Heat Pumps
    By: Joanna R. Turpin
Subscription Center
  • Create an Account
  • Start a Subscription
  • Manage My Account
  • Sign Up for Newsletters
  • Visit Customer Service
  • Update Preferences

More Videos

Sponsored Content

Sponsored Content is a special paid section where industry companies provide high quality, objective, non-commercial content around topics of interest to The News audience. All Sponsored Content is supplied by the advertising company and any opinions expressed in this article are those of the author and not necessarily reflect the views of The News or its parent company, BNP Media. Interested in participating in our Sponsored Content section? Contact your local rep!

close
  • Piggy Bank
    Sponsored byWatercress Financial

    Energy Prices, Inflation, and HVAC: What Today’s Homeowners Care About

  • Refrigerated Food
    Sponsored bySolstice Advanced Materials

    R-455A Refrigeration: A Cold Storage Solution for the Future

  • Airex Rooftop Units
    Sponsored byAirex Manufacturing Inc

    Consolidating Roof Penetrations: A Growing Trend in Multifamily HVAC Design

Popular Stories

HVAC-Price-Increase-graphic

HVAC Price Increase List: June 2026

Trump-Section-232.jpg

Trump Reduces Section 232 Tariffs on HVAC Equipment to 15%

R410A-Refrigerant-Cylinder.jpg

Refrigerant Recovery is a Revenue Opportunity

Heat-pump-cutaway.jpg

PFAS Rules and A2L Building Codes Continue to Evolve

Midea-training.jpg

HVAC Workforce Crisis Expands Beyond Technicians to Instructor Shortages

View The ACHR NEWS
Centennial Anniversary Timeline

The ACHR News Timeline Chart
Submit a Letter
Submit a letter to our editors.

Events

November 6, 2025

Next-Gen Data Center Cooling: HVAC Innovation and Real-World Solutions

On Demand As AI workloads and high-density computing push traditional cooling methods to their limits, the data center industry is accelerating the adoption of next-generation HVAC technologies.

June 17, 2026

Decarbonization Without Disruption

This webinar will explore practical HVAC decarbonization strategies that minimize disruption while maximizing long-term performance and ROI.

View All Submit An Event

Poll

Summer Staff

Are you fully staffed for the summer season?
View Results Poll Archive

Products

BNI Mechanical/Electrical Square Foot Costbook, 2026 Edition

BNI Mechanical/Electrical Square Foot Costbook, 2026 Edition

See More Products
Decarbonization Without Disruption - Free Webinar - 6/17/2026

Related Articles

  • May 18, 2012: SMACNA’s HVAC Air Duct Leakage Test Manual Receives ANSI Accreditation

    See More
  • May 17, 2011: SMACNA Introduces Free iPhone App to Estimate Air Duct Leakage

    See More
  • AABC Low Leakage Duct

    Mike Kelly on Duct Leakage, Craftsmanship, and the Invisible Costs of Air

    See More

Related Products

See More Products
  • HVAC Air Duct Leakage Test Manual, 2nd Edition

  • test manual.gif

    HVAC Air Duct Leakage Test Manual

See More Products
×

Sign Up. Stay Informed.

The #1 trusted source for the HVACR industry since 1926

SUBSCRIBE
  • RESOURCES
    • Advertise
    • Contact Us
    • Advisory Board
    • Classifieds
    • Submit a Letter
    • Directories
    • Store
  • ACCOUNT CENTER
    • Create an Account
    • Start a Subscription
    • Manage My Account
    • Sign Up for Newsletters
    • Visit Customer Service
    • Update Preferences
  • SERVICES
    • Marketing Services
    • Reprints
    • Market Research
    • List Rental
    • Survey/Respondent Access
  • STAY CONNECTED
    • LinkedIn
    • Facebook
    • Instagram
    • YouTube
    • X (Twitter)
  • PRIVACY
    • PRIVACY POLICY
    • TERMS & CONDITIONS
    • DO NOT SELL MY PERSONAL INFORMATION
    • PRIVACY REQUEST
    • ACCESSIBILITY

Copyright ©2026. All Rights Reserved BNP Media, Inc. and BNP Media II, LLC.

Design, CMS, Hosting & Web Development :: ePublishing