the NEWS
Advertisement:
HVACR Directory | Extra Edition | Learning Center | Editorial Blogs | Product Gallery
  Home
  About the NEWS
  Subscription Info
  e-Newsletters
  Contact Us
  Resources
  Archived Editorial
  Blogs
  Career Center - Employers
  Career Center - Job Seekers
  Columns
  Distributor Corner
  Calendar of Events
  HVACR Directory
  Industry Links
  Learning Center
  Letters
  Manufacturer Reports
  Regional Reports
  Reprints
  Survey Says
  Training Track
  Webinars
  AEC Store
  Market Research
  Extra Edition
  HVACR Forum
  Legal forum
  Business Management
  Dot Comment
  Energy Matters
  Features
  Newsline
  People
  Service Hotline
  Service & Maintenance
  Technical
  Advertising
  Ad Index
  Media Kit
  Submit Press Release
  Services
  Classifieds
  Digital Edition
  Post Cards
Search in: EditorialProductsCompanies
Btu Buddy 71: Dry House Problem
by Bill Johnson
February 16, 2009

ARTICLE TOOLS
EmailEmailPrintPrintReprintsReprintsshareShare



Bob is a service technician who is well trained and nationally certified. However, he sometimes suffers from the same confusion that all technicians occasionally do — the facts that he gathers may or may not point to the obvious cause of the problem or the best solution. But Bob has something that no one else has. He recalls his long-time HVACR mentor and imagines him accompanying him as “Btu Buddy,” someone who reminds him to take time to stop and think before rushing to judgment, helping keep him on the right track, even with facts that are confusing.


Enlarge this picture
Figure 1. This is a photo of a cabinet door that is showing shrinkage due to low humidity. (Click on the image for an enlarged view.)
Bob got a call from a customer who said her house was so dry that the wood was shrinking. He wasn’t sure what she was talking about until he arrived at the house and talked to her.

She explained that the painted surfaces on some of her cabinets were shrinking to the point that she could see the unpainted surfaces (Figure 1).

Bob looked around the house and could see signs of wood shrinkage in several places. He was standing there scratching his head when Btu Buddy made an appearance and asked, “What is the problem, Bob?”

Bob said, “Boy am I glad to see you. This house is so dry that the wood is drying up and shrinking. I have never noticed that before, until the homeowner showed it to me. I don’t know why a house would be so dry.”


Figure 2. 2-A (above) shows an older sling psychrometer; 2-B (below) shows newer electronic instruments for taking humidity readings. (Figure is from Refrigeration & Air Conditioning Technology, 5th Edition, by William Whitman, William Johnson, and John Tomczyk, published by Delmar Cengage Learning.)
Btu Buddy then asked Bob if he knew what level of humidity the house was maintaining.

Bob said, “No, but I can take a reading and find out.”

Bob went to the truck and brought in his sling psychrometer (Figure 2) and took some readings. He then said, “This house is very dry; the humidity is down to about 15 percent. What should the humidity be?”

Btu Buddy said, “Most people in the industry would like to hold the humidity somewhere between 40 percent and 60 percent for a typical home. Below 40 percent is uncomfortable and the wood in the house will begin to suffer. If the humidity is above 60 percent, mold can grow in some places in the house.”

Bob then said, “I wonder why the humidity in this home is so low.”


Btu Buddy said, “This house is about 25 years old, so we should look for several things. To start with, I would think that the house is not nearly as tight as modern homes. If there is too much infiltration, the humidity will be low. For example, when outdoor air at 35°F at 50 percent humidity enters through infiltration, and it is mixed with indoor air at about 70°, the indoor humidity level drops to about 19 percent. That is a large drop in humidity (Figure 3). Houses of older construction have much more infiltration than the newer constructed houses. Many of the older houses have 50 percent of the air changed out in the house every hour; certainly an older house would have at least 25 percent of the air changed every hour. It is easy to see from the chart, that would easily lower the humidity in the house.”

Bob then asked, “How in the world can that much air change out in a house? It would seem like it would be like a wind tunnel.”


Enlarge this picture
Figure 3. An excerpt from a psychrometric chart showing air entering at 35°F and 50 percent humidity mixing with air in the home at 70° and the humidity of that air dropping to 19 percent. (Figure is from Practical Cooling Technology by William Johnson, published by Delmar Cengage Learning.) (Click on the image for an enlarged view.)
Btu Buddy explained, “All houses are subject to the prevailing breeze or wind. The air is rarely still. The wind causes a positive pressure on one side of the house, and when it drops off of the other side of the house, it creates a negative pressure (Figure 4). This causes air to enter on the positive side and exit on the negative side. The house is a vessel, but it is not an air tight vessel.”

Bob then asked, “Now what do we do?”

Btu Buddy then suggested, “I think you should show the owner what is going on with the structure and suggest that she get a contractor to offer suggestions. Your company can explore and repair some of the problems. The air distribution duct system can also cause excess outdoor air to be pulled into the structure. If the supply duct leaks, the return air will cause the home to go into a slight vacuum, sucking in outdoor air. If the return duct leaks, it will suck in outdoor air from either under the house or the attic when the duct is routed in these locations. This will force air into the structure and put it into a positive pressure. You can check those yourself and instigate a repair. Meanwhile, you can install a humidifier in the central duct system and a humidistat to help stabilize the humidity in the house.”


Enlarge this picture
Figure 4. This illustration shows how infiltration air enters a structure from the prevailing breezes. (Figure is from Practical Heating Technology by William Johnson, published by Delmar Cengage Learning.) (Click on the image for an enlarged view.)
Bob explained all of this to the homeowner and she told him to go ahead with the duct examination and repair and to add a humidifier.

Bob found several places in the supply duct that needed attention. He also applied mastic to all of the duct connections that he could access. He then turned his attention to the return duct and found several places where it was obvious that air was leaking in and repaired them. He then called the company and asked for a duct pressure test technician to come out and test the duct for leaks. They did this by taping all duct outlets and returns and applied a fan to the furnace fan section and pulled room air into the duct system pressurizing it. They then measured the amount of leakage and told Bob that he had done a good job of sealing the system. It had very little leakage.

Meanwhile, a contractor showed up and Bob explained what was going on. The contractor looked around and suggested to the homeowner that she had storm windows that were not great, but adequate. He looked under the sinks on the outside walls and suggested that all penetrations to the home be sealed, including plumbing and electrical (Figure 4). He explained to her that it would take a few materials and only a few hours to complete this job.

Bob then said, “Now for the big question: What type of humidifier should we use?”

Btu Buddy responded, “That is a big question. You are not going to install it today. Let’s go to lunch and explore that topic with some research.”

Bob said, “Well, this simple job turned into a learning experience, but I love it.”

Publication date: 02/16/2009


Bill Johnson
Active in the HVACR industry since the 1950s, Bill Johnson graduated in gas fuel technology and refrigeration from the Southern Technical Institute, a branch of Georgia Tech (now known as Southern Polytechnic Institute). He taught HVAC classes at Coosa Valley Vocational & Technical Institute for four years. He moved on to become service manager for Layne Trane, Charlotte, N.C. He taught for 15 years at Central Piedmont Community College, part of this time as program director. He had his own business for five years doing installation and service work. Now retired, he is the author of "Practical Heating Technology" and "Practical Cooling Technology," and continues as a co-author of "Refrigeration & Air Conditioning Technology," 5th Edition, all published by Delmar Cengage Learning. For more information, he can be reached at 704-553-0087, 704-643-3928 (fax), or billj@carolina.rr.com.