Engineered Systems NEWSHVAC Engineering SectorsVentilation and IAQCommercial HVAC

Misunderstood CO2: IAQ And Beyond

Why is carbon dioxide so misunderstood? And what role does it play in IAQ and ventilation?

By Stephanie Taylor, M.D., M. Arch, CIC
Figure 1: model of carbon dioxide molecules

Figure 1: model of carbon dioxide molecules.

January 4, 2017

Now that I have your attention, let’s talk about the pros and cons of inhaled carbon dioxide.

Carbon dioxide (CO2) is generally thought of as a bad thing. Engineers usually monitor indoor CO2 levels as an indicator of appropriate ventilation to manage unpleasant smells such as body odors, but they do not consider it a toxin itself. Public opinion tends be more negative, regarding CO2 as only a waste product or even a toxin, sometimes confusing it with carbon monoxide. In fact, this is far from true! Let’s take a closer look at the role of this maligned little molecule in human (and all mammalian) physiology so that we can strive for ventilation that promotes health without becoming excessive.

 

One of life’s essential nutrients

CO2, like oxygen, is essential for human life, and blood levels need to be precisely regulated. Metabolically active tissues such as our muscles release CO2, which then rapidly forms carbonic acid (H2CO3) in our bloodstream. Carbonic acid is a critical acid-base modulator that maintains our body pH within a narrow and healthy range. Eventually, excess CO2 is removed from the body via the lungs in exhaled air.

One common misconception is that CO2 and oxygen are antagonistic, so that when the blood level of one rises, the other one is crowded out and correspondently decreases. This is incorrect! A person’s blood may be high in both gases, or low in both gases, because each are transported by different means and each promotes the diffusion of the other. In the 1800s, scientists Bohr and Verigo found that dissolved CO2 in the blood is needed to release the oxygen carried by hemoglobin. Therefore, when carbonic acid levels are even slightly low, oxygen supply to critical tissues in the body such as the brain, heart, kidneys, and muscles is decreased.

Another misunderstanding for many people is the belief that breathing is stimulated by low oxygen levels. Again, this is incorrect. Normally elevated blood CO2 is what triggers our next breath. Many kids over the years have experimented with intentionally hyperventilating before an underwater race. By breathing rapidly, we lower our blood CO2 level and thereby reduce our respiratory drive, allowing us to break our usual breath holding limit. While we might win the underwater race because of reduced air hunger, we risk drowning. Our unnaturally low CO2 causes rapidly diminishing oxygen to be held onto tightly by hemoglobin, making it unavailable to our oxygen-starved brain and greatly increasing our chance of an underwater blackout.

Chronically low levels of CO2 leads to abnormal nerve and muscle excitability, causing the familiar symptoms of hyperventilation such as “pins and needles” and muscle cramps in one’s hands and feet, dizziness, visual disturbances, and anxiety. Insufficient CO2 can also cause more serious muscle contractions that worsen asthma attacks, migraines, high blood pressure, and chest pain.

 

At what inhaled concentration does CO2 become toxic to humans?

Dalton’s law can be applied to determine the partial pressures of individual gases exchanged between inhaled air in the lungs and the blood stream:

 

p(air) = p(N2) + p(O2) + p(CO2) + …

 

At sea level air pressure (760 mm Hg), the air consists of 78% nitrogen, 21% oxygen, and 0.04% CO2 so each of these three molecules exerts the following pressure:

 

N2: (78/100)*760 = 593 mm Hg

O2: (21/100)*760 = 160 mm Hg

CO2: (0.04/100)*760 = 0.3 mm Hg

 

The partial pressure of the CO2 in our blood generated by metabolic processes is approximately 45 mm Hg, or 6%, which equals 60,000 ppm. For this CO2 to cross from the blood to the lungs, the inhaled air simply needs to have a downhill partial pressure gradient. Therefore, theoretically, the partial pressure of CO2 in the air that we breathe just needs to be less than 60,000 ppm! Since this is the lethal level of CO2, conventional wisdom tells us to give ourselves some leeway with indoor ventilation standards. Exactly how much lower is argued, but at least we can relate our ppm goal to human physiology rather than to inherited levels based on body odors! ES

Share This Story

Looking for a reprint of this article?
From high-res PDFs to custom plaques, order your copy today!

 

Dr. Stephanie Taylor is the president and founder of Building4Health Inc. After working as a physician for many decades, Dr. Taylor obtained a Masters in Architecture as well as Infection Control certification. Her lifelong commitment to patient care includes focusing on improving the healthcare physical environment and clinical work processes to help patients heal quickly and save hospitals valuable dollars. Dr. Taylor is a graduate of Harvard Medical School (MD), and Norwich University (Masters Architecture). She has numerous research publications in Nature, Science, and other peer-reviewed journals. She can be contacted at stephanie@b4hinc.com or (860) 501-8950.

Recommended Content

JOIN TODAY
To unlock your recommendations.

Already have an account? Sign In

  • HVAC-enrollment

    The Trades Are Back: HVACR Programs See Nearly 30% Enrollment Spike

    A new wave of future technicians is entering the pipeline.  
    Training and Education
    By: Matt Jachman
  • 2025 Top 40 Under 40

    2025 Top 40 Under 40 HVACR Professionals List

    The 11th annual Top 40 Under 40 list highlights those...
    HVAC Commercial Market
    By: Hannah Belloli-Oster
  • LG Ductless Mini-Split Systems

    The 9 Types of Heat Pumps

    As the U.S. moves toward electrification, heat pumps are...
    Ground Source Heat Pumps
    By: Joanna R. Turpin

More Videos

Today's Boiler

Spring 2026 Issue

Today's Boiler - Spring 2026 Cover

Read More from Today's Boiler

Case in Point Logo

Smarter Hydronic Design for Data Centers - Free Webinar - January 22, 2026

Related Articles

  •  Progression of viral hosts from a zoonotic source to a human pandemic

    IAQ and Emerging Infectious Diseases

    See More
  • A Physical View IAQ

    Beyond The Hard Hat: IAQ On The Job Site

    See More
  • As standards and mandates evolve to require healthy indoor environments, the building owners who pay for capital costs will be more motivated to manage IAQ to protect occupants.

    Incentives and obstacles in managing IAQ for occupant health

    See More

Related Products

See More Products
  • 9781482255676.jpg

    Testing and Balancing HVAC Air and Water Systems, Fifth Edition

  • Manual B.jpg

    Manual B - Balancing and Testing Air and Hydronic Systems

See More Products

Events

View AllSubmit An Event
  • May 19, 2026

    Addressing IAQ, Humidification, and Dehumidification Issues for Your Customers

    On Demand This webinar from The ACHR NEWS will examine how IAQ and dehumidification strategies differ, and overlap, across residential and commercial applications.
  • December 9, 2025

    Beyond Smart Buildings: Why BMS Needs to Move Past Division 23 — For Every Building

    On Demand Let’s reframe Division 25 not as a lofty ideal, but as a practical and alternate approach to specifying facility systems such as a building management systems (BMS).
View AllSubmit An Event

Related Directories

  • TRION IAQ

    Trade NamesAir Bear®Air Boss®ComfortSteam®Forever Filter®Grease Viper™Herrdraulic®Herricane®Herrmersion®Herrmidicool®Herrmidifier®Herrmidisteam®Herrtronic®Trion®
×

Sign Up. Stay Informed.

The #1 trusted source for the HVACR industry since 1926

SUBSCRIBE
  • RESOURCES
    • Advertise
    • Contact Us
    • Advisory Board
    • Classifieds
    • Submit a Letter
    • Directories
    • Store
  • ACCOUNT CENTER
    • Create an Account
    • Start a Subscription
    • Manage My Account
    • Sign Up for Newsletters
    • Visit Customer Service
    • Update Preferences
  • SERVICES
    • Marketing Services
    • Reprints
    • Market Research
    • List Rental
    • Survey/Respondent Access
  • STAY CONNECTED
    • LinkedIn
    • Facebook
    • Instagram
    • YouTube
    • X (Twitter)
  • PRIVACY
    • PRIVACY POLICY
    • TERMS & CONDITIONS
    • DO NOT SELL MY PERSONAL INFORMATION
    • PRIVACY REQUEST
    • ACCESSIBILITY

Copyright ©2026. All Rights Reserved BNP Media, Inc. and BNP Media II, LLC.

Design, CMS, Hosting & Web Development :: ePublishing