ACHR News
search
Ask ACHR NEWS AI
cart
facebook twitter instagram linkedin youtube
  • Sign In
  • Subscribe
  • Sign Out
  • My Account
ACHR News
  • NEWS
    • Breaking News
    • New HVAC Products
    • Featured Products
    • Manufacturer Reports
    • HVAC Data
    • Legislation
    • ACHR NEWS Centennial
  • RESIDENTIAL
    • Air Conditioners
    • Furnaces
    • Residential Heat Pumps
    • Ductless
    • Residential IAQ
    • Testing, Monitoring, Tools
    • Components & Accessories
  • COMMERCIAL
    • Air Handlers
    • Rooftop Units
    • Chillers and Cooling Towers
    • Commercial Heat Pumps
    • Boilers and Hydronics
    • VRF/Ductless
    • Commercial IAQ
  • REFRIGERATION
    • Refrigerants
    • Refrigerant Regulations
    • Leak Management
  • CONTRACTOR PRO
    • Geothermal
    • Homeowner Study
    • VRF and VRV Ductless
    • Unitary Trends
  • EDUCATION
    • Training and Education
    • Business Management
    • Service and Maintenance
    • Continuing Education
    • Market Research >
      • HVAC Brand Awareness Report
      • VRV, VRF, VRVZ Report
      • Unitary Trends Report
      • Water Heat Professionals Report
    • Webinars
    • Sponsor Insights
    • eProducts Info
    • White Papers
  • EVENTS
    • HVAC Contractor Forum
    • Industry Events and Webinars
  • MEDIA
    • Videos
    • AHR Expo 2025 Videos
    • Podcasts >
      • ACHR News Podcast
      • HARDI Podcasts
      • AHR Expo Podcasts
      • ACCA Podcasts
    • Interactive Spotlights
    • Quizzes
    • eBooks
    • HVAC Talkback
  • HVAC GROUP
    • ACHR NEWS >
      • Current Issue
      • Digital Edition
      • Subscribe
    • Distribution Trends
    • SNIPS NEWS >
      • Join SNIPS NEWS
    • Engineered Systems News >
      • Join ES News
    • HVACR Directory
    • Contests
    • Newsletters
    • Contact
    • Advertise
    • My Account

The Hotline: 04/07/2003

April 2, 2003

Cap Tube Charging

QUESTION:
By John West
Chesterfield, Va.

My question involves the proper way to charge a cap tube or fixed orifice metering device. I know that weighing in is the best option. But what if that is not available?

What would be a good subcooling and superheat? And please offer some suggestions on the proper tools to get results. I have seen techs using a pocket thermometer to get superheat readings.

ANSWER:
From Dan Kramer, P.E.
Specialist Grade Member of RSES,
Professional Engineer

If you are charging a new capillary or fixed restrictor system with field-installed lines between the condensing unit and evaporator, you should evacuate to 500 microns or less using a vacuum gauge that reads in microns. I have a little pocket micron gauge — the DV-22 from J/B Industries — that works beautifully. The vacuum should hold without rising more than a couple hundred microns over a few minutes. A continuous rise indicates a leak. A short, sharp rise suggests moisture.

If the factory charge weight is unavailable, I would charge by superheat. In my opinion, the best instrument for superheat measurement is made by Concept Technology. The company is in Hazelwood, Mo., and its telephone number is 314-837-6385. The unit has a built-in computer that stores pressure-temperature charts for several common refrigerants and has plug-ins for most of the new refrigerants. You strap the temperature bulb to the suction line and hook your gauge hose to the suction line tap and read superheat directly.

I wish I had an electronic scale. But because I don’t, I use a bathroom scale and write down the beginning weight of the refrigerant cylinder.

You should hang a thermometer at the condenser air inlet and adjust the entering air temperature to about 95 degrees F by redirecting some warm air off the condenser back to the air inlet.

Looking for quick answers on air conditioning, heating and refrigeration topics? Try Ask ACHR NEWS, our new smart AI search tool. Ask ACHR NEWS →

I prefer to charge to about 8 degrees F superheat with inlet air to the evaporator at about 72 degrees F. That’s pretty cold. That way, under most reasonable operating conditions, the air to the evaporator will be warmer and the superheat will be higher, thereby providing safe operating conditions for the compressor.

When charging is complete, write down the cylinder final weight. Subtract the final cylinder weight from the start weight and write down the charge weight on a sticker you place on the unit. That way, next time, you can just charge the same system by weight.

Remember that most 400 series refrigerants (zeotropes) have to charge in the liquid state. Pure refrigerants like R-22 or -134a can be charged by vapor.

If you are recharging an old system, I would install a line-tap valve on the condenser outlet and monitor the high-side pressure while charging. If you have correctly evacuated before charging, you can be pretty sure you don’t have non-condensibles. However, a plugged or restricted capillary will require you to charge an abnormally large amount of refrigerant before the superheat comes down.

With the high-side pressure and a liquid line thermometer, you should be able to detect subcooling greater than about 15 degrees F. That suggests an overcharge. Should that happen, my preferred practice would be to uncharge back into a recovery cylinder, purge with nitrogen, cut out the cap tube, and replace with a properly sized TXV with a liquid sight glass at its inlet. Evacuating and recharging would be as for a TXV.

Evacuation Level Of 410A

QUESTION:
By Bill Smith
Sealed Unit Parts
Allenwood, N.J.

I have a question about the evacuation levels for R-410A/POE oil systems.

American Standard points out, “Proper evacuation to 500 microns will remove moisture from an R-22 mineral oil system. However, evacuation to 500 microns will not sufficiently remove moisture from a system using POE oils such as those used with R-410A.”

What is the suggested evacuation level for 410A systems?

ANSWER:
From Dave Bell
Service Training Specialist
Copeland
Sidney, Ohio

At least one large system manufacturer that utilizes 410A and polyol ester (POE) lubricant says to evacuate to 500 microns. This deep vacuum method is used to evacuate air and noncondensibles, which may include moisture, from the system.

With 410A you must use an approved POE lubricant. One characteristic of the POE is that it is very hygroscopic. This means it has the ability to attract moisture at a high rate. POE also has the ability to hold this absorbed moisture and not release it under a vacuum. The moisture that is trapped in the POE can be removed by the use of the proper liquid line drier. As in any system, multiple drier changes may be required depending on the level of trapped moisture.

Evacuation is important for the removal of air and noncondensibles. Also, use the proper liquid line drier to remove any moisture that may be trapped.

Pulling A Vacuum

QUESTION:
By John West
Chesterfield, Va.

My question involves pulling vacuum on air conditioning units. Would a large vacuum pump — say a 35 to 50 cfm unit that you use on a large chiller — be as effective on a small 3-ton system? What would be the appropriate rise in pressure on your gauge or micron gauge to signal that you have a leak?

ANSWER:
From Dan Kramer, P.E.
Specialist Grade Member of RSES,
Professional Engineer

I see no reason why a high-volume vacuum pump could not be used to evacuate a smaller system.

However, in that case — as in any vacuum pump application — there are three basic rules:

  • First, you should use only an electronic vacuum gauge that reads down to a few hundred microns.

  • Second, the gauge should be connected directly to the system being evacuated.

  • Third, there should be a shut-off valve between the pump and the system.

    The presence of a leak would be indicated not by a given number of microns rise in pressure, but by a continuous rise over a period of time. An immediate significant pressure rise after the shut-off valve is closed might simply indicate some residual refrigerant or air dissolved in the oil, or possibly some moisture remaining in the system.

    In that case, open the shut-off and continue the evacuation. When the pressure reaches 500 microns and the valve is shut and the pressure rises only to 600 or 650 microns and then stops rising, I would say the evacuation is complete. If the pressure continues rising, even slowly, I would suspect a leak.

    Remember, never to start a hermetic compressor while it is evacuated since that could precipitate internal arcing and a subsequent motor burnout.

    Missing Filter-Driers

    QUESTION:
    By Robert Hunter
    Via E-mail

    I’m a homeowner that had a new central A/C unit installed five years ago. I had to have the outside unit replaced due to compressor failure. The company informed me that there were no driers installed on the old unit. Would this have caused the old compressor to fail?

    ANSWER:
    From Bill Mosher
    Commercial Products Manager
    Parker Hannifin Corp.
    Lyons, N.Y.

    Unfortunately, there is not enough information to conclude whether a missing drier had any impact on the compressor failure. Parker recommends having the compressor sent back to the manufacturer for analysis.

    As a filter-drier manufacturer, we always recommend the installation of a filter-drier on an air conditioning system. Some system manufacturers integrate the dryer into their units. Others provide “drop-in” dryers to be brazed within the liquid line upon installation.

    Filter-driers are a system protector. They filter out debris, water, and acids. They are designed to protect expansion valves, flow raters, and compressors from the prior mentioned contaminants. However, the lack of a drier on your system may not be the reason for your compressor’s failure.

    If you have a technical question, fax it to 847-622-7266 or submit it online on The Hotline page.

    Publication date: 04/07/2003

  • Share This Story

    Looking for a reprint of this article?
    From high-res PDFs to custom plaques, order your copy today!

     

    Recommended Content

    JOIN TODAY
    To unlock your recommendations.

    Already have an account? Sign In

    • HVAC-enrollment

      The Trades Are Back: HVACR Programs See Nearly 30% Enrollment Spike

      A new wave of future technicians is entering the pipeline.  
      Training and Education
      By: Matt Jachman
    • 2025 Top 40 Under 40

      2025 Top 40 Under 40 HVACR Professionals List

      The 11th annual Top 40 Under 40 list highlights those...
      HVAC Commercial Market
      By: Hannah Belloli-Oster
    • LG Ductless Mini-Split Systems

      The 9 Types of Heat Pumps

      As the U.S. moves toward electrification, heat pumps are...
      Heat Pumps
      By: Joanna R. Turpin
    Subscription Center
    • Create an Account
    • Start a Subscription
    • Manage My Account
    • Sign Up for Newsletters
    • Visit Customer Service
    • Update Preferences

    More Videos

    Sponsored Content

    Sponsored Content is a special paid section where industry companies provide high quality, objective, non-commercial content around topics of interest to The News audience. All Sponsored Content is supplied by the advertising company and any opinions expressed in this article are those of the author and not necessarily reflect the views of The News or its parent company, BNP Media. Interested in participating in our Sponsored Content section? Contact your local rep!

    close
    • Piggy Bank
      Sponsored byWatercress Financial

      Energy Prices, Inflation, and HVAC: What Today’s Homeowners Care About

    • Refrigerated Food
      Sponsored bySolstice Advanced Materials

      R-455A Refrigeration: A Cold Storage Solution for the Future

    • Airex Rooftop Units
      Sponsored byAirex Manufacturing Inc

      Consolidating Roof Penetrations: A Growing Trend in Multifamily HVAC Design

    Popular Stories

    HVAC-Price-Increase-graphic

    HVAC Price Increase List: June 2026

    Trump-Section-232.jpg

    Trump Reduces Section 232 Tariffs on HVAC Equipment to 15%

    Refrigerants-and-gauge.jpg

    HVAC Industry Warns of Counterfeit Refrigerants Entering U.S. Supply Chain

    Heat-pump-cutaway.jpg

    PFAS Rules and A2L Building Codes Continue to Evolve

    Midea-training.jpg

    HVAC Workforce Crisis Expands Beyond Technicians to Instructor Shortages

    View The ACHR NEWS
    Centennial Anniversary Timeline

    The ACHR News Timeline Chart
    Submit a Letter
    Submit a letter to our editors.

    Events

    November 6, 2025

    Next-Gen Data Center Cooling: HVAC Innovation and Real-World Solutions

    On Demand As AI workloads and high-density computing push traditional cooling methods to their limits, the data center industry is accelerating the adoption of next-generation HVAC technologies.

    June 17, 2026

    Decarbonization Without Disruption

    This webinar will explore practical HVAC decarbonization strategies that minimize disruption while maximizing long-term performance and ROI.

    View All Submit An Event

    Poll

    Summer Staff

    Are you fully staffed for the summer season?
    View Results Poll Archive

    Products

    BNI Mechanical/Electrical Square Foot Costbook, 2026 Edition

    BNI Mechanical/Electrical Square Foot Costbook, 2026 Edition

    See More Products
    Decarbonization Without Disruption - Free Webinar - 6/17/2026

    Related Articles

    • The Hotline: 08/04/2003

      See More
    • The Hotline: 06/07/2004

      See More
    • The Hotline: 06/07/2004

      See More

    Related Products

    See More Products
    • Modern Geothermal HVAC Engineering and Control Applications

    • Uncomplicating The Heat Pump: Refrigeration & Air Flow Systems DVD

    See More Products

    Related Directories

    • The Whalen Co.

      The Whalen Company is the pioneering manufacturer of HVAC vertical stack riser heat-exchanger fan coil units and water-source heat pumps for hotels, apartments and other multi-story buildings.
    ×

    Sign Up. Stay Informed.

    The #1 trusted source for the HVACR industry since 1926

    SUBSCRIBE
    • RESOURCES
      • Advertise
      • Contact Us
      • Advisory Board
      • Classifieds
      • Submit a Letter
      • Directories
      • Store
    • ACCOUNT CENTER
      • Create an Account
      • Start a Subscription
      • Manage My Account
      • Sign Up for Newsletters
      • Visit Customer Service
      • Update Preferences
    • SERVICES
      • Marketing Services
      • Reprints
      • Market Research
      • List Rental
      • Survey/Respondent Access
    • STAY CONNECTED
      • LinkedIn
      • Facebook
      • Instagram
      • YouTube
      • X (Twitter)
    • PRIVACY
      • PRIVACY POLICY
      • TERMS & CONDITIONS
      • DO NOT SELL MY PERSONAL INFORMATION
      • PRIVACY REQUEST
      • ACCESSIBILITY

    Copyright ©2026. All Rights Reserved BNP Media, Inc. and BNP Media II, LLC.

    Design, CMS, Hosting & Web Development :: ePublishing