ACHR News
search
Ask ACHR NEWS AI
cart
facebook twitter instagram linkedin youtube
  • Sign In
  • Subscribe
  • Sign Out
  • My Account
ACHR News
  • NEWS
    • Breaking News
    • New HVAC Products
    • Featured Products
    • Manufacturer Reports
    • HVAC Data
    • Legislation
    • ACHR NEWS Centennial
  • RESIDENTIAL
    • Air Conditioners
    • Furnaces
    • Residential Heat Pumps
    • Ductless
    • Residential IAQ
    • Testing, Monitoring, Tools
    • Components & Accessories
  • COMMERCIAL
    • Air Handlers
    • Rooftop Units
    • Chillers and Cooling Towers
    • Commercial Heat Pumps
    • Boilers and Hydronics
    • VRF/Ductless
    • Commercial IAQ
  • REFRIGERATION
    • Refrigerants
    • Refrigerant Regulations
    • Leak Management
  • CONTRACTOR PRO
    • Geothermal
    • Homeowner Study
    • VRF and VRV Ductless
    • Unitary Trends
  • EDUCATION
    • Training and Education
    • Business Management
    • Service and Maintenance
    • Continuing Education
    • Market Research >
      • HVAC Brand Awareness Report
      • VRV, VRF, VRVZ Report
      • Unitary Trends Report
      • Water Heat Professionals Report
    • Webinars
    • Sponsor Insights
    • eProducts Info
    • White Papers
  • EVENTS
    • HVAC Contractor Forum
    • Industry Events and Webinars
  • MEDIA
    • Videos
    • AHR Expo 2025 Videos
    • Podcasts >
      • ACHR News Podcast
      • HARDI Podcasts
      • AHR Expo Podcasts
      • ACCA Podcasts
    • Interactive Spotlights
    • Quizzes
    • eBooks
    • HVAC Talkback
  • HVAC GROUP
    • ACHR NEWS >
      • Current Issue
      • Digital Edition
      • Subscribe
    • Distribution Trends
    • SNIPS NEWS >
      • Join SNIPS NEWS
    • Engineered Systems News >
      • Join ES News
    • HVACR Directory
    • Contests
    • Newsletters
    • Contact
    • Advertise
    • My Account
Service and MaintenanceHVAC Residential MarketRefrigeration

Subcooling Is The Missing Piece Of The Puzzle

August 14, 2002
In past articles I’ve written about superheat as a charging and diagnostic tool. There are actually four pieces to the refrigerant system diagnostic puzzle:

1. Suction pressure;

2. High-side pressure;

3. Superheat; and

4. Subcooling.

In this article, let’s talk about subcooling.

(To get a bigger picture of refrigerant system diagnostics, take a look at my two-part article on superheat published in the August 13, 2001 and Sept. 17, 2001 issues of The News.)

SUBCOOLING IN A/C

To simplify my description of subcooling, I’ll use the air conditioning mode as an example. As you know, when the liquid refrigerant in the evaporator absorbs the heat from the indoor air, it boils off to a gaseous form. This refrigerant gas is pulled out of the evaporator, taking the heat energy that it absorbed with it.

The compressor compresses the refrigerant into a high-pressure gas, which increases its temperature at the same time. This high-temperature, high-pressure gas enters the condenser and begins dissipating the heat that it absorbed to the outdoor air.

As heat is removed from the refrigerant, it eventually turns back into a liquid. This liquid stacks up in the bottom of the condenser circuits, waiting to exit the condenser and return to the evaporator via the liquid line. There must be liquid in the liquid line or the system will not function. If there is any gas in the liquid line (bubbling sight glass), the system will behave as if it is restricted, and the evaporator will be starved of refrigerant.

Having the proper amount of liquid stacked up in the bottom of the condenser is critical because as the load on the air conditioning system increases, the amount of liquid required in the evaporator increases. The liquid stored in the condenser supplies the increase in liquid needed for the evaporator to operate properly and prevents the condenser from running out of liquid refrigerant at higher load conditions.

When charging an air conditioner, it is not only critical to ensure the proper refrigerant level in the evaporator (with superheat), but also a proper level in the condenser. To do this, we check how much subcooling the system is creating.

Subcooling is a measurement of how much the liquid in the condenser cools down before exiting. When the hot gas in the condenser first turns to liquid, its temperature is at the saturation point. This means that the temperature of the liquid as it first forms is at the same temperature at which the refrigerant is condensing — the saturation temperature.

Looking for quick answers on air conditioning, heating and refrigeration topics? Try Ask ACHR NEWS, our new smart AI search tool. Ask ACHR NEWS →

SATURATION TEMPERATURE

As an example, look at a refrigerant temperature-pressure chart. Let’s use R-22 for this exercise. As its pressure changes, its saturation temperature also changes.

Saturation temperature is the temperature at which the refrigerant will either condense or boil, depending on whether it is gas or liquid, respectively. What this means to you is that if you know the pressure of the liquid in the liquid line as it exits the condenser coil, you also know the temperature of the liquid as it was created.

Let’s say that the liquid pressure in a system you are working on is 242 pounds (Figure 1). The temperature-pressure chart tells you that R-22 will turn into a liquid at 115 degrees F. That 115 degree liquid gets blown down to the bottom of the coil and must wait its turn to exit. While it continues to drain through the coil, it gives up more heat before it can leave. The general rule of thumb is that it should give up about 10 degrees before it leaves the condenser coil. If your system is working properly, the liquid temperature leaving the coil should be 105 degrees.

The more refrigerant is stacked in the condenser, the more time it has to travel through the condenser, so it gives up more heat or becomes more subcooled (lower temperature). If there is less refrigerant in the bottom of the coil, it has less time to travel through the coil, so it gives up less heat (becomes less subcooled).

The convenient thing about this is that by checking the subcooling, you can tell how much refrigerant is in the condenser.

A reminder why subcooling is important: Among other things, if the subcooling is too low, the condenser will “run out of” refrigerant prematurely at higher load conditions, overheating the compressor and reducing performance and efficiency. If the subcooling is too high, the system will be overcharged, reducing performance, efficiency, and ultimately damaging compressor valves and start components.

SUBCOOLING IN DIAGNOSTICS

So far I’ve talked about subcooling as a charging tool, but it is also an invaluable tool for diagnosing troublesome systems. In fact, if you diagnose a refrigerant system without using subcooling, you have only been guessing.

Imagine you have two systems with orifice metering devices that have refrigerant system problems. One has a liquid restriction with a normal charge; the other one is undercharged. They both have abnormally low high- and low-side pressures and abnormally high superheat. The only difference between the two systems will be their subcooling. The restricted machine will have abnormally high subcooling and the undercharged machine will have abnormally low subcooling.

(By the way, many techs seem to think that, contrary to the previous example, a system with a liquid restriction exhibits low suction and high head pressures. This is not the case — although a liquid-restricted system will have excessively high head pressure after several techs misdiagnose it as undercharged and add refrigerant to get the suction pressure up.)

SUBCOOLING CONSIDERATIONS

Here are some things to consider when you use subcooling as a charging or diagnosis tool:

  • The 10 degrees subcooling rule of thumb is just a rule of thumb. Many machines out there were designed to operate at 15 degrees subcooling. In addition, many variables besides refrigerant charge affect subcooling, like airflow, coil matching, metering device type, and sizing, as well as coil cleanliness.

  • A low airflow or dirty evaporator can raise subcooling. A dirty condenser can lower subcooling. Too large an orifice will also lower subcooling (and visa versa).

  • To calculate subcooling properly, you must use liquid pressure, not discharge pressure.

  • When measuring the liquid line temperature, ensure that your temperature probe is very tight to the liquid line and insulated to get the most accurate reading.

  • Ensure that your high-side pressure gauge is accurate. Small inaccuracies can make your calculations worthless.

    Some manufacturers are now including subcooling charts with their systems, but, for the most part, you are on your own when it comes to using subcooling to service machines. The best way to deal with this is to measure subcooling on every system you put your gauges on.

    Do this for a couple of weeks without necessarily taking any action as a result of your subcooling measurements. If you are observant enough, as time goes on, you will start to see the interrelationships between a system’s subcooling and any problems it might have.

    By giving yourself some time to get acquainted with subcooling, you will avoid over-diagnosing systems during your learning curve. Once you get it, you’ll never go back.

    Howard Leonard is president of Total Tech HVACR Training, Phoenix, AZ. His firm specializes in service, installation, and application training for service technicians. He can be reached at 602-943-2517.

    Publication date: 08/19/2002

  • Share This Story

    Looking for a reprint of this article?
    From high-res PDFs to custom plaques, order your copy today!

     

    Recommended Content

    JOIN TODAY
    To unlock your recommendations.

    Already have an account? Sign In

    • HVAC-enrollment

      The Trades Are Back: HVACR Programs See Nearly 30% Enrollment Spike

      A new wave of future technicians is entering the pipeline.  
      News
      By: Matt Jachman
    • 2025 Top 40 Under 40

      2025 Top 40 Under 40 HVACR Professionals List

      The 11th annual Top 40 Under 40 list highlights those...
      HVAC Commercial Market
      By: Hannah Belloli-Oster
    • LG Ductless Mini-Split Systems

      The 9 Types of Heat Pumps

      As the U.S. moves toward electrification, heat pumps are...
      News
      By: Joanna R. Turpin
    Subscription Center
    • Create an Account
    • Start a Subscription
    • Manage My Account
    • Sign Up for Newsletters
    • Visit Customer Service
    • Update Preferences

    More Videos

    Sponsored Content

    Sponsored Content is a special paid section where industry companies provide high quality, objective, non-commercial content around topics of interest to The News audience. All Sponsored Content is supplied by the advertising company and any opinions expressed in this article are those of the author and not necessarily reflect the views of The News or its parent company, BNP Media. Interested in participating in our Sponsored Content section? Contact your local rep!

    close
    • Piggy Bank
      Sponsored byWatercress Financial

      Energy Prices, Inflation, and HVAC: What Today’s Homeowners Care About

    • Refrigerated Food
      Sponsored bySolstice Advanced Materials

      R-455A Refrigeration: A Cold Storage Solution for the Future

    • Airex Rooftop Units
      Sponsored byAirex Manufacturing Inc

      Consolidating Roof Penetrations: A Growing Trend in Multifamily HVAC Design

    Popular Stories

    HVAC-Price-Increase-graphic

    HVAC Price Increase List: June 2026

    Trump-Section-232.jpg

    Trump Reduces Section 232 Tariffs on HVAC Equipment to 15%

    Heat-pump-cutaway.jpg

    PFAS Rules and A2L Building Codes Continue to Evolve

    Midea-training.jpg

    HVAC Workforce Crisis Expands Beyond Technicians to Instructor Shortages

    Refrigerants-and-gauge.jpg

    HVAC Industry Warns of Counterfeit Refrigerants Entering U.S. Supply Chain

    View The ACHR NEWS
    Centennial Anniversary Timeline

    The ACHR News Timeline Chart
    Submit a Letter
    Submit a letter to our editors.

    Events

    November 6, 2025

    Next-Gen Data Center Cooling: HVAC Innovation and Real-World Solutions

    On Demand As AI workloads and high-density computing push traditional cooling methods to their limits, the data center industry is accelerating the adoption of next-generation HVAC technologies.

    June 17, 2026

    Decarbonization Without Disruption

    This webinar will explore practical HVAC decarbonization strategies that minimize disruption while maximizing long-term performance and ROI.

    View All Submit An Event

    Poll

    Summer Staff

    Are you fully staffed for the summer season?
    View Results Poll Archive

    Products

    BNI Mechanical/Electrical Square Foot Costbook, 2026 Edition

    BNI Mechanical/Electrical Square Foot Costbook, 2026 Edition

    See More Products
    Decarbonization Without Disruption - Free Webinar - 6/17/2026

    Related Articles

    • The Internet Is Just One Piece Of The Puzzle

      See More
    • Google Poised to Take a Piece of the HVAC Pie

      See More
    • The Case of the Missing Service Calls

      See More

    Related Products

    See More Products
    • new cover.jpg

      Profit is An Attitude: The Strategies You Need to Optimize Profits

    • Understanding TXV Refrigeration Systems: Superheat and Subcooling DVD

    • Uncomplicating The Heat Pump: Refrigeration & Air Flow Systems DVD

    See More Products

    Events

    View AllSubmit An Event
    • May 21, 2026

      The A2L Genie is Out of the Refrigerant Canister – What Now?

      On Demand Join this webinar to learn about key updates to refrigerant regulations. We will cover practical installation and servicing content gathered from thousands of our interactions with contractors across the US and Canada.
    View AllSubmit An Event
    ×

    Sign Up. Stay Informed.

    The #1 trusted source for the HVACR industry since 1926

    SUBSCRIBE
    • RESOURCES
      • Advertise
      • Contact Us
      • Advisory Board
      • Classifieds
      • Submit a Letter
      • Directories
      • Store
    • ACCOUNT CENTER
      • Create an Account
      • Start a Subscription
      • Manage My Account
      • Sign Up for Newsletters
      • Visit Customer Service
      • Update Preferences
    • SERVICES
      • Marketing Services
      • Reprints
      • Market Research
      • List Rental
      • Survey/Respondent Access
    • STAY CONNECTED
      • LinkedIn
      • Facebook
      • Instagram
      • YouTube
      • X (Twitter)
    • PRIVACY
      • PRIVACY POLICY
      • TERMS & CONDITIONS
      • DO NOT SELL MY PERSONAL INFORMATION
      • PRIVACY REQUEST
      • ACCESSIBILITY

    Copyright ©2026. All Rights Reserved BNP Media, Inc. and BNP Media II, LLC.

    Design, CMS, Hosting & Web Development :: ePublishing