ACHR News
search
Ask ACHR NEWS AI
cart
facebook twitter instagram linkedin youtube
  • Sign In
  • Subscribe
  • Sign Out
  • My Account
ACHR News
  • NEWS
    • Breaking News
    • New HVAC Products
    • Featured Products
    • Manufacturer Reports
    • HVAC Data
    • Legislation
    • ACHR NEWS Centennial
  • RESIDENTIAL
    • Air Conditioners
    • Furnaces
    • Residential Heat Pumps
    • Ductless
    • Residential IAQ
    • Testing, Monitoring, Tools
    • Components & Accessories
  • COMMERCIAL
    • Air Handlers
    • Rooftop Units
    • Chillers and Cooling Towers
    • Commercial Heat Pumps
    • Boilers and Hydronics
    • VRF/Ductless
    • Commercial IAQ
  • REFRIGERATION
    • Refrigerants
    • Refrigerant Regulations
    • Leak Management
  • CONTRACTOR PRO
    • Geothermal
    • Homeowner Study
    • VRF and VRV Ductless
    • Unitary Trends
  • EDUCATION
    • Training and Education
    • Business Management
    • Service and Maintenance
    • Continuing Education
    • Market Research >
      • HVAC Brand Awareness Report
      • VRV, VRF, VRVZ Report
      • Unitary Trends Report
      • Water Heat Professionals Report
    • Webinars
    • Sponsor Insights
    • eProducts Info
    • White Papers
  • EVENTS
    • HVAC Contractor Forum
    • Industry Events and Webinars
  • MEDIA
    • Videos
    • AHR Expo 2025 Videos
    • Podcasts >
      • ACHR News Podcast
      • HARDI Podcasts
      • AHR Expo Podcasts
      • ACCA Podcasts
    • Interactive Spotlights
    • Quizzes
    • eBooks
    • HVAC Talkback
  • HVAC GROUP
    • ACHR NEWS >
      • Current Issue
      • Digital Edition
      • Subscribe
    • Distribution Trends
    • SNIPS NEWS >
      • Join SNIPS NEWS
    • Engineered Systems News >
      • Join ES News
    • HVACR Directory
    • Contests
    • Newsletters
    • Contact
    • Advertise
    • My Account

Regular coil cleaning improves system efficiency and building IAQ

September 19, 2000
Coil care is an important component of maintaining an hvac system and the indoor air quality (IAQ) of a building. Properly cleaned coils contribute to the overall efficiency of the hvac system, and help provide “healthy” air to the building’s occupants.

Among the factors that are involved in keeping coils clean, one of the most important is having a well-maintained filter system. The use of antimicrobial products for cleaning and controlling the growth of organisms that can cause illness is also a key.

The design of the coils contributes to their cleanability and influences the method of cleaning.

Proper filtration

The single most important factor in keeping coil surfaces clean is proper filtration of the airstream. Particles in the air not only clog coils and reduce their efficiency, but also enter the occupied spaces of a building and cause IAQ problems.

The first step in keeping the coils clean is careful filter maintenance. Filters need to be inspected and replaced frequently, following the manufacturer’s recommendations.

A dirty, clogged filter will not keep the air clean and can impede the passage of the airstream. In fact, the fan may actually begin to pull on the filter media, even tearing it out of the frame. This leaves gaps that enable air to pass through the hvac system without any filtration.

Standard 2-in. filters that many commercial buildings use have an average efficiency of less than 20%. They eliminate larger particles that can build up on coils, but they do not screen out and reduce spores and other contaminants that may affect the health of building occupants.

To address IAQ concerns, filter manufacturers have developed higher-efficiency filters that can help keep both the airstream and the coils cleaner. These extended-surface, pleated filters offer efficiencies of 35% to 40%, and while they cost more, are more effective at removing smaller particles from the air.

We now understand that filtering the smaller microbial particles is even more important than removing nuisance dust. A study by the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) on the effects of microbes on IAQ, stressed that controlling airborne microbes is a major challenge, because they contain organisms such as bacteria, fungi, algae, pollen, and viruses.

Looking for quick answers on air conditioning, heating and refrigeration topics? Try Ask ACHR NEWS, our new smart AI search tool. Ask ACHR NEWS →

Many of these particles cause allergic reactions and even various infectious diseases. Other studies indicate that fungi and bacteria account for nearly twice the number of causes of IAQ problems as dust.

In fact, it has been determined that dust accounts for only 25% of the particulate that causes IAQ problems in a building.

Cooling coils and drain pans, the most likely areas to trap microbes and dirt in the hvac system, can act as reservoirs for microbial growth. As water vapor condenses in the air passing over the coils, particulate matter is washed out of the airstream and can collect on the coils and in the drain pan.

This wet, dark, temperature-controlled environment is perfect for the growth of molds and fungi, which can then be circulated by the fan into occupied spaces.

Controlling microbes

For this reason, newer standards require double-sloped rather than flat drain pans. Coil cleaning and sanitizing products with biocidal characteristics can help control the microbial growth on these surfaces.

It is important to clean both the coils and the drain pans at the same time. All surfaces should be thoroughly rinsed when the cleaning is completed.

When considering cleaning products, look for those that are easy to apply. Many are caustic and acidic, relying on strong chemical interactions to remove microbial growth (and often the top layers of the metal).

Fortunately, new products employ surfactant technology (as opposed to brute chemical strength) to clean coils. Not only are these products better for the coils, they are also more environmentally friendly.

Other cleaning methods include a pressure pump sprayer with hot water and an environmentally friendly detergent applied to all sides of the coil.

Cleaning surfaces within the hvac system is only the beginning, however. Controlling growth once the surface is clean is equally important. A variety of antimicrobial products continue to control the growth of microbes for three to six months after application. These can easily be incorporated into regular maintenance.

It also is important to be aware of worker safety. EPA registration is the assurance to the contractor that the product is safe for the intended use. Read product labels carefully, to ensure that the product is registered; and follow the directions.

Design issues

Considerations for cleaning actually begin with the application and specifications of the coils.

Consider the number of rows deep, fin corrugation, fin style, fin spacing, fin material, and thickness. All of these factors will influence the ease of cleaning (which usually has a large bearing on whether or not it is actually done).

The depth of the coils makes a difference as to how easy it is to clean them. The depth is often determined by the arrangement of the tubes (staggered or inline) within the coil. In general, a six-row inline tube pattern coil is the same depth as an eight-row staggered tube pattern coil. For ease of cleaning, the tubes in the coil should not exceed four rows.

This means that in eight-row applications, the tubes should be split into two four-row sections, with space to clean each coil from both sides. The coils could be piped in series or parallel; selections should be made accordingly.

There are several types and configurations of coil fins to select. All of them have differing characteristics that influence the coil’s efficiency and cleanability. These fin styles include plate, spiral, and lanced.

Plate fins feature alternating ridges and grooves called corrugation. Highly corrugated fins provide maximum performance and air pressure drop (APD). Mildly corrugated fins require two more fins/in. to achieve the performance of highly corrugated fins, but the APD is 30% to 35% lower even with the extra two fins.

Flat fins have no corrugation on the face, but the edges may have corrugation to add strength. They require two additional fins/in. to achieve mildly corrugated performance, but their APD will be 30% to 40% lower than mildly corrugated fins.

In addition, the lack of corrugation on flat fins reduces fin strength so, depending on the method of cleaning, a heavier-than-normal fin material would be recommended to avoid damage. While this improves cleanability, it also increases the first cost.

Spiral fins are usually tapered and held in place by notches around the inner diameter of the fin. These notches may catch lint and dirt, and are extremely difficult to clean. This fin is best described as a stretched out “slinky.” Damage to the fin may cause it to snap, exposing bare tube to the airstream.

Lanced fins, the result of technological advances in tooling and manufacturing, have slots extruded off each side of the fins’ face. This exposes more secondary surfaces to the airstream, resulting in greater performance per row. However, the lanced fin is extremely thin. Efforts to clean it may result in damage, even to the extent of requiring a new coil.

The number of fins/in. will also make a difference in cleaning. Normally, wider fin spacings are desirable for easier coil cleaning. Eight fins/in. is usually requested to create the most easily serviced arrangement.

However, this means that selections requiring more fins/in. than specified will result in more rows and deeper fin depth. This makes the coil more difficult to clean and again drives up the first cost.

Condenser coils are probably the worst from this standpoint, because they usually have a high number of fins/in. (14-plus). In addition, they have no filters to protect the coils from dust and airborne particles, such as cottonwood seeds, which can clog the coils.

Regular schedule

As with most building maintenance programs, coil cleaning is more likely to be done if it is part of a regular schedule. While a maintenance schedule must be customized to the specific application to be effective, there are some ground rules to follow in establishing one.

Any cleaning-maintenance program should be based on hours of usage, not months. This ensures that hvac systems with heavier use get adequate maintenance attention. It’s a good idea to clean the coils and drain pans at the time the filters are changed. Moving clean air over dirty coils will not provide cleaner air for occupants.

Because all surfaces in an indoor environment can contribute to poor IAQ, it’s important to take your efforts beyond the air filters and cooling coils. For example, applying an antimicrobial treatment to the interior housing when the coils and filters are treated will further curb microbial growth.

IAQ continues to be a major issue that building managers and hvac contractors must address. Among the areas that will certainly come under additional scrutiny are coil design and maintenance.

As coil cleaning becomes more of an issue, it may well increase the cost of future applications. However, designing for it now will keep cleaning costs down, equipment efficiency up, and occupants’ health and productivity optimal.

Share This Story

Looking for a reprint of this article?
From high-res PDFs to custom plaques, order your copy today!

 

Recommended Content

JOIN TODAY
To unlock your recommendations.

Already have an account? Sign In

  • HVAC-enrollment

    The Trades Are Back: HVACR Programs See Nearly 30% Enrollment Spike

    A new wave of future technicians is entering the pipeline.  
    News
    By: Matt Jachman
  • 2025 Top 40 Under 40

    2025 Top 40 Under 40 HVACR Professionals List

    The 11th annual Top 40 Under 40 list highlights those...
    HVAC Contracting
    By: Hannah Belloli-Oster
  • LG Ductless Mini-Split Systems

    The 9 Types of Heat Pumps

    As the U.S. moves toward electrification, heat pumps are...
    Heat Pumps
    By: Joanna R. Turpin
Subscription Center
  • Create an Account
  • Start a Subscription
  • Manage My Account
  • Sign Up for Newsletters
  • Visit Customer Service
  • Update Preferences

More Videos

Sponsored Content

Sponsored Content is a special paid section where industry companies provide high quality, objective, non-commercial content around topics of interest to The News audience. All Sponsored Content is supplied by the advertising company and any opinions expressed in this article are those of the author and not necessarily reflect the views of The News or its parent company, BNP Media. Interested in participating in our Sponsored Content section? Contact your local rep!

close
  • Piggy Bank
    Sponsored byWatercress Financial

    Energy Prices, Inflation, and HVAC: What Today’s Homeowners Care About

  • Refrigerated Food
    Sponsored bySolstice Advanced Materials

    R-455A Refrigeration: A Cold Storage Solution for the Future

  • Airex Rooftop Units
    Sponsored byAirex Manufacturing Inc

    Consolidating Roof Penetrations: A Growing Trend in Multifamily HVAC Design

Popular Stories

HVAC-Price-Increase-graphic

HVAC Price Increase List: June 2026

Trump-Section-232.jpg

Trump Reduces Section 232 Tariffs on HVAC Equipment to 15%

R410A-Refrigerant-Cylinder.jpg

Refrigerant Recovery is a Revenue Opportunity

Heat-pump-cutaway.jpg

PFAS Rules and A2L Building Codes Continue to Evolve

Kroger.jpg

Kroger to Spend $100 Million to Reduce Refrigerant Leaks

View The ACHR NEWS
Centennial Anniversary Timeline

The ACHR News Timeline Chart
Submit a Letter
Submit a letter to our editors.

Events

November 6, 2025

Next-Gen Data Center Cooling: HVAC Innovation and Real-World Solutions

On Demand As AI workloads and high-density computing push traditional cooling methods to their limits, the data center industry is accelerating the adoption of next-generation HVAC technologies.

June 17, 2026

Decarbonization Without Disruption

This webinar will explore practical HVAC decarbonization strategies that minimize disruption while maximizing long-term performance and ROI.

View All Submit An Event

Poll

Summer Staff

Are you fully staffed for the summer season?
View Results Poll Archive

Products

BNI Mechanical/Electrical Square Foot Costbook, 2026 Edition

BNI Mechanical/Electrical Square Foot Costbook, 2026 Edition

See More Products
A2L Refrigerants - Free Webinar - May 21, 2026

Related Articles

  • coil

    Goodway Technologies: Coil Cleaning System

    See More
  • Pro Vac Sac Inc.: Stationary-Coil Cleaning System

    See More
  • Monday, Jan. 26, 2009: SpeedClean Introduces Portable Coil Cleaning System

    See More

Related Products

See More Products
  • Manual Q.jpg

    Manual Q - Low Pressure, Low Velocity Duct System Design

  • Green Tips for Building Maintenance Engineers

See More Products

Related Directories

  • SpeedClean

    SpeedClean manufactures and markets HVAC maintenance tools like portable coil cleaning systems, biodegradable coil cleaners, tube cleaners, mini-split cleaning systems and much more.
  • Efficient Building Automation Corp.

    Efficient Building Automation Corporation provides products, systems, services and support that enable our partners to deliver open and integrated LonWorks building automation solutions of unequalled quality, reliability and performance.
×

Sign Up. Stay Informed.

The #1 trusted source for the HVACR industry since 1926

SUBSCRIBE
  • RESOURCES
    • Advertise
    • Contact Us
    • Advisory Board
    • Classifieds
    • Submit a Letter
    • Directories
    • Store
  • ACCOUNT CENTER
    • Create an Account
    • Start a Subscription
    • Manage My Account
    • Sign Up for Newsletters
    • Visit Customer Service
    • Update Preferences
  • SERVICES
    • Marketing Services
    • Reprints
    • Market Research
    • List Rental
    • Survey/Respondent Access
  • STAY CONNECTED
    • LinkedIn
    • Facebook
    • Instagram
    • YouTube
    • X (Twitter)
  • PRIVACY
    • PRIVACY POLICY
    • TERMS & CONDITIONS
    • DO NOT SELL MY PERSONAL INFORMATION
    • PRIVACY REQUEST
    • ACCESSIBILITY

Copyright ©2026. All Rights Reserved BNP Media, Inc. and BNP Media II, LLC.

Design, CMS, Hosting & Web Development :: ePublishing