ACHR News
search
Ask ACHR NEWS AI
cart
facebook twitter instagram linkedin youtube
  • Sign In
  • Subscribe
  • Sign Out
  • My Account
ACHR News
  • NEWS
    • Breaking News
    • New HVAC Products
    • Featured Products
    • Manufacturer Reports
    • HVAC Data
    • Legislation
    • ACHR NEWS Centennial
  • RESIDENTIAL
    • Air Conditioners
    • Furnaces
    • Residential Heat Pumps
    • Ductless
    • Residential IAQ
    • Testing, Monitoring, Tools
    • Components & Accessories
  • COMMERCIAL
    • Air Handlers
    • Rooftop Units
    • Chillers and Cooling Towers
    • Commercial Heat Pumps
    • Boilers and Hydronics
    • VRF/Ductless
    • Commercial IAQ
  • REFRIGERATION
    • Refrigerants
    • Refrigerant Regulations
    • Leak Management
  • CONTRACTOR PRO
    • Geothermal
    • Homeowner Study
    • VRF and VRV Ductless
    • Unitary Trends
  • EDUCATION
    • Training and Education
    • Business Management
    • Service and Maintenance
    • Continuing Education
    • Market Research >
      • HVAC Brand Awareness Report
      • VRV, VRF, VRVZ Report
      • Unitary Trends Report
      • Water Heat Professionals Report
    • Webinars
    • Sponsor Insights
    • eProducts Info
    • White Papers
  • EVENTS
    • HVAC Contractor Forum
    • Industry Events and Webinars
  • MEDIA
    • Videos
    • AHR Expo 2025 Videos
    • Podcasts >
      • ACHR News Podcast
      • HARDI Podcasts
      • AHR Expo Podcasts
      • ACCA Podcasts
    • Interactive Spotlights
    • Quizzes
    • eBooks
    • HVAC Talkback
  • HVAC GROUP
    • ACHR NEWS >
      • Current Issue
      • Digital Edition
      • Subscribe
    • Distribution Trends
    • SNIPS NEWS >
      • Join SNIPS NEWS
    • Engineered Systems News >
      • Join ES News
    • HVACR Directory
    • Contests
    • Newsletters
    • Contact
    • Advertise
    • My Account

Preventive maintenance: Keeping refrigeration equipment in shape

June 7, 1999
If an owner expects his refrigeration equipment to perform reliably for many years, preventive maintenance is a necessity.

When equipment constantly breaks down or doesn’t perform to expectations, it’s often because there has never been any preventive maintenance — only emergency service. Remember, equipment is only as good as the service performed on it.

All mechanical equipment needs periodic service to keep it in the best operating condition. Good service can mean the difference between a few mechanical malfunctions or continuous problems.

The following is a guide to developing a comprehensive preventive maintenance program.

To properly maintain a system, all the major components should be included in the maintenance schedule. These include the evaporator(s), compressor unit, and condenser.

For this article, only air-cooled condensing units will be discussed. Units with water-cooled condensers or towers require specific inspection methods, but the other components of those systems can be considered within the context of this article.

Evaporators

Check the evaporators monthly for proper defrosting. Ice accumulation on the evaporator coil can cause inefficiencies in the operation of the system, and can be detrimental to the coil surface itself.

Every six months:

1. Tighten all electrical connections in the electrical panel.

Check for frayed wiring insulation and corroded terminals, and make certain all spade connections are tight.

Looking for quick answers on air conditioning, heating and refrigeration topics? Try Ask ACHR NEWS, our new smart AI search tool. Ask ACHR NEWS →

2. Check fan motors and blades.

Do the blades turn freely? Check the blades for unusual wear patterns or stress fractures. Clean the surface of each fan blade. Replace any worn blades and tighten the fan set screws.

On motors with lubrication fittings, apply the correct lubricant. Replace any motor that is hard to rotate or has worn bearings.

3. Check all defrost heaters.

Make certain heaters are in the correct position for maximum heat transfer to the evaporator coil. Follow the manufacturer’s recommendations.

Check each heater for correct amp draw.

Check the voltage at each heater terminal.

Make certain the heater terminals are in good condition.

4. Clean the drain pan and check for proper drainage.

All foreign material should be removed from the drain pan. The pan should drain freely.

The drain line should be free-draining with visible slope away from the evaporator.

Check the drain line heater in applications below freezing.

5. Clean the evaporator coil surface.

The coil should be washed periodically to remove dust and other foreign materials that might have been drawn into the fins. A commercial-grade cleaning foam can be used. Follow the label directions of the appropriate cleaner to clean refrigerant coils.



Compressor Units

Every six months:

1. Tighten all electrical connections.

Check for frayed wiring insulation and corroded terminals. Replace damaged wiring.

Make certain all spade connections are tight.

2. Check all electrical components.

Electrical contactors should be inspected closely for worn and pitted contact points. The points should be cleaned and polished. Check for any discoloration in the conductors, which may indicate a loose wire or a dangerous overcurrent condition. Any foreign material found in the contactor should be removed.

Inspect the defrost timer motor. Clean the contact points and lubricate the gears of the clock. Make certain the entire clock mechanism rotates freely.

Check all relays for worn points; replace relay if necessary.

Check the electrical connections inside the compressor electrical box.

3. Check the operation of the control system.

Check all pressure controls for proper operation and setpoints.

Check the safety controls. Make certain the oil safety and high pressure controls are functioning.

Check the operation of the room temperature thermostat. Make certain the liquid line solenoid valve closes completely and the compressor pumps down and cycles off.

4. Check the oil level in the compressor.

The oil level should be at or between one-third and two-thirds of the sight glass.

Check the operation of the crankcase heater.

5. Check the operation of the defrost controls.

Under most conditions, the timer should initiate the defrost. Make certain the defrost termination temperature control stops the defrost cycle and allows the evaporator fans approximately 2 min of delay time before restart.

6. Check the condition of refrigerant line insulation.

Open, torn, or waterlogged insulation provides little benefit to the system. If the insulation is in poor condition, replace it.

7. Check for the proper refrigerant level in the system.

The liquid line sight glass should be clear and full of liquid refrigerant during normal operation. If not, find and repair the leak, then charge enough refrigerant into the system to maintain a clear sight glass.

8. Check the system superheat at the condensing unit.

Suction superheat should be checked at the compressor as follows.

a) Measure the suction pressure at the suction service valve of the compressor and determine the saturation temperature corresponding to this pressure from a temperature-pressure chart.

b) Measure the suction temperature of the suction line about 1 ft back from the compres-sor using an accurate ther-mometer.

c) Subtract the saturated temperature from the actual suction line temperature. The difference is superheat.

Too low a suction superheat can result in liquid being returned to the compressor. This causes dilution of the oil and eventual failure of the bearings, rings or, possibly, valve failure.

Too high a suction superheat will result in excessive discharge temperatures, which cause the oil to break down and result in piston ring wear and piston and cylinder wall damage.

For maximum system capacity, suction superheat should be kept as low as practical. (Heatcraft recommends the superheat at the compressor be no lower than 30°F.) If adjustments to the suction superheat need to be made, the expansion valve at the evaporator should be adjusted. Follow the manufacturer’s recommendations.

9. Check all capillary and super hose lines for signs of wear.

Make certain all capillary and super hose lines are secure and do not rub against objects that can cause refrigerant leaks.

10. Replace all missing valve caps and unit covers.

Condensers

Every six months (sooner if local conditions cause clogging or fouling of air passages through the finned surface), perform the following:

1. The condenser coil should be cleaned and washed.

Clean periodically with a brush, vacuum cleaner, pressurized water, or commercially available coil cleaning foam. If a foam cleaner is used, it should not be acid based. Follow the label directions of the appropriate cleaner.

2. Check the operation of the condenser fans.

Check that each fan freely rotates.

Tighten all fan set screws.

Check the fan blades for signs of stress or other wear features. If any unusual wear is seen, replace the blade.

Lubricate the motors if applicable. (Most condenser motors are permanently sealed and do not require lubricating.) Replace any motor that is worn.

Important: Fill out a maintenance log and leave it with the owner or with the equipment after each periodic inspection. This log should be available for future reference. It is also advisable to retain a copy of the operating parameters at the time of the inspection.

Steve Maxson is an application engineer for Heatcraft Refrigeration Products, Stone Mountain, Ga.; 770-465-5600; 770-465-5990 (fax); www.heat craftrpd.com (website).

Share This Story

Looking for a reprint of this article?
From high-res PDFs to custom plaques, order your copy today!

 

Recommended Content

JOIN TODAY
To unlock your recommendations.

Already have an account? Sign In

  • HVAC-enrollment

    The Trades Are Back: HVACR Programs See Nearly 30% Enrollment Spike

    A new wave of future technicians is entering the pipeline.  
    News
    By: Matt Jachman
  • 2025 Top 40 Under 40

    2025 Top 40 Under 40 HVACR Professionals List

    The 11th annual Top 40 Under 40 list highlights those...
    HVAC Commercial Market
    By: Hannah Belloli-Oster
  • LG Ductless Mini-Split Systems

    The 9 Types of Heat Pumps

    As the U.S. moves toward electrification, heat pumps are...
    HVAC Commercial Market
    By: Joanna R. Turpin
Subscription Center
  • Create an Account
  • Start a Subscription
  • Manage My Account
  • Sign Up for Newsletters
  • Visit Customer Service
  • Update Preferences

More Videos

Sponsored Content

Sponsored Content is a special paid section where industry companies provide high quality, objective, non-commercial content around topics of interest to The News audience. All Sponsored Content is supplied by the advertising company and any opinions expressed in this article are those of the author and not necessarily reflect the views of The News or its parent company, BNP Media. Interested in participating in our Sponsored Content section? Contact your local rep!

close
  • Piggy Bank
    Sponsored byWatercress Financial

    Energy Prices, Inflation, and HVAC: What Today’s Homeowners Care About

  • Refrigerated Food
    Sponsored bySolstice Advanced Materials

    R-455A Refrigeration: A Cold Storage Solution for the Future

  • Airex Rooftop Units
    Sponsored byAirex Manufacturing Inc

    Consolidating Roof Penetrations: A Growing Trend in Multifamily HVAC Design

Popular Stories

HVAC-Price-Increase-graphic

HVAC Price Increase List: June 2026

Trump-Section-232.jpg

Trump Reduces Section 232 Tariffs on HVAC Equipment to 15%

R410A-Refrigerant-Cylinder.jpg

Refrigerant Recovery is a Revenue Opportunity

Heat-pump-cutaway.jpg

PFAS Rules and A2L Building Codes Continue to Evolve

Midea-training.jpg

HVAC Workforce Crisis Expands Beyond Technicians to Instructor Shortages

View The ACHR NEWS
Centennial Anniversary Timeline

The ACHR News Timeline Chart
Submit a Letter
Submit a letter to our editors.

Events

November 6, 2025

Next-Gen Data Center Cooling: HVAC Innovation and Real-World Solutions

On Demand As AI workloads and high-density computing push traditional cooling methods to their limits, the data center industry is accelerating the adoption of next-generation HVAC technologies.

June 17, 2026

Decarbonization Without Disruption

This webinar will explore practical HVAC decarbonization strategies that minimize disruption while maximizing long-term performance and ROI.

View All Submit An Event

Poll

Summer Staff

Are you fully staffed for the summer season?
View Results Poll Archive

Products

BNI Mechanical/Electrical Square Foot Costbook, 2026 Edition

BNI Mechanical/Electrical Square Foot Costbook, 2026 Edition

See More Products
Decarbonization Without Disruption - Free Webinar - 6/17/2026

Related Articles

  • Preventive maintenance: Keeping refrigeration equipment in shape

    See More
  • May 6, 2014: Commercial Refrigeration Equipment Demand in the US to Reach $10.7 Billion

    See More
  • Preventive Maintenance for Small Refrigeration Units

    See More

Related Products

See More Products
  • HVAC and Refrigeration Preventive Maintenance.jpeg

    HVAC and Refrigeration Preventive Maintenance

  • Tech_CommRef_Guide_Small.jpg

    Technician’s Guide & Workbook for Quality Maintenance on Commercial Refrigeration Equipment

  • Semi-Hermetic Compressors: Testing, Servicing & Isolating DVD

See More Products

Related Directories

  • Refrigeration Equipment Pros

    Refrigeration Equipment Professionals (REP) is a reputable and experienced provider of surplus and used refrigeration equipment. Our firm provides quality used refrigeration equipment with consistent delivery times that meet our client's expectations. We are a supply house to our representative equipment contractors and dealers in North America and Latin America, as well as agent representatives in the Middle East and Asia.
  • KeepRite Refrigeration

    Leading North American manufacturer of commercial refrigeration products, including specialized applications in food storage and processing, industrial process cooling, including evaporator coils, condensing units, condensers, and heat transfer/recovery.
×

Sign Up. Stay Informed.

The #1 trusted source for the HVACR industry since 1926

SUBSCRIBE
  • RESOURCES
    • Advertise
    • Contact Us
    • Advisory Board
    • Classifieds
    • Submit a Letter
    • Directories
    • Store
  • ACCOUNT CENTER
    • Create an Account
    • Start a Subscription
    • Manage My Account
    • Sign Up for Newsletters
    • Visit Customer Service
    • Update Preferences
  • SERVICES
    • Marketing Services
    • Reprints
    • Market Research
    • List Rental
    • Survey/Respondent Access
  • STAY CONNECTED
    • LinkedIn
    • Facebook
    • Instagram
    • YouTube
    • X (Twitter)
  • PRIVACY
    • PRIVACY POLICY
    • TERMS & CONDITIONS
    • DO NOT SELL MY PERSONAL INFORMATION
    • PRIVACY REQUEST
    • ACCESSIBILITY

Copyright ©2026. All Rights Reserved BNP Media, Inc. and BNP Media II, LLC.

Design, CMS, Hosting & Web Development :: ePublishing