ACHR News
search
Ask ACHR NEWS AI
cart
facebook twitter instagram linkedin youtube
  • Sign In
  • Subscribe
  • Sign Out
  • My Account
ACHR News
  • NEWS
    • Breaking News
    • New HVAC Products
    • Featured Products
    • Manufacturer Reports
    • HVAC Data
    • Legislation
    • ACHR NEWS Centennial
  • RESIDENTIAL
    • Air Conditioners
    • Furnaces
    • Residential Heat Pumps
    • Ductless
    • Residential IAQ
    • Testing, Monitoring, Tools
    • Components & Accessories
  • COMMERCIAL
    • Air Handlers
    • Rooftop Units
    • Chillers and Cooling Towers
    • Commercial Heat Pumps
    • Boilers and Hydronics
    • VRF/Ductless
    • Commercial IAQ
  • REFRIGERATION
    • Refrigerants
    • Refrigerant Regulations
    • Leak Management
  • CONTRACTOR PRO
    • Geothermal
    • Homeowner Study
    • VRF and VRV Ductless
    • Unitary Trends
  • EDUCATION
    • Training and Education
    • Business Management
    • Service and Maintenance
    • Continuing Education
    • Market Research >
      • HVAC Brand Awareness Report
      • VRV, VRF, VRVZ Report
      • Unitary Trends Report
      • Water Heat Professionals Report
    • Webinars
    • Sponsor Insights
    • eProducts Info
    • White Papers
  • EVENTS
    • HVAC Contractor Forum
    • Industry Events and Webinars
  • MEDIA
    • Videos
    • AHR Expo 2025 Videos
    • Podcasts >
      • ACHR News Podcast
      • HARDI Podcasts
      • AHR Expo Podcasts
      • ACCA Podcasts
    • Interactive Spotlights
    • Quizzes
    • eBooks
    • HVAC Talkback
  • HVAC GROUP
    • ACHR NEWS >
      • Current Issue
      • Digital Edition
      • Subscribe
    • Distribution Trends
    • SNIPS NEWS >
      • Join SNIPS NEWS
    • Engineered Systems News >
      • Join ES News
    • HVACR Directory
    • Contests
    • Newsletters
    • Contact
    • Advertise
    • My Account

A very forgiving refrigeration system

April 28, 2000
To explore the ways that controls and components improve equipment efficiency, experiments have been conducted on a large, cell-type, automatic ice machine that produces approximately 1,800 lb/day of quality ice.

This ice machine incorporates a critical charge (46 oz) of R-402B, a near-azeotropic, HCFC-based refrigerant blend of 38% R-125, 2% R-290, and 60% R-22. This ice-making machine also contains two evaporators, two non-adjustable TXVs, a hot gas defrost system, liquid receiver, coaxial (tube within a tube) water-cooled condenser, and a water-regulating valve (Figure 1).

The water-cooled condenser adds to the compactness and quietness of the system. The amount of ice produced per day is dependent upon the incoming water temperature to the evaporator’s sump and to the surrounding air temperature around the ice machine.

Notice in Chart 1, that as the entering water temperature gets warmer, the ice-making capacity decreases. Also, as the surrounding air temperature gets warmer, the ice-making capacity decreases. Both conditions of warmer entering water and surrounding air temperatures add extra heat load on the evaporators of the ice machine. Thus, the time it takes to make a complete slab of cubed ice is longer. The capacity of the ice machine is decreased in both situations.

This ice machine is located at Ferris State University’s Commercial Refrigeration Laboratory in Big Rapids, MI, and is used daily by students and university personnel. The machine is operated every day of the year.

The ice machine was first critically charged, followed by intentional overcharging and undercharging to see what inefficiencies in ice-making capacity, if any, would be observed.

Chart 2 shows the pertinent system information of three system checks for a critical charge, undercharge, and an overcharge of refrigerant. This chart also reveals that for the critical charge, undercharge, and overcharge of refrigerant, all system data pretty much look alike and are acceptable.

The condensing temperature, condenser subcooling, evaporator superheat, and compressor (total) superheat all pretty much look similar, whether the system is critically charged to the nameplate charge, overcharged by 5 oz, or undercharged by 5 oz. What follows are explanations of these system operating conditions.

Condensing pressure and temperature

The condensing temperature is controlled by a water-regulating valve (Figures 3 and 4). This valve is designed to maintain a constant condensing head pressure whatever the heat load on the ice machine may be.

The water-regulating valve is in series with the water-cooled condenser (Figure 4). The valve has a closing pressure mechanism that is a large adjustable spring on its top. This adjustable spring is where the technician can set the desired condensing pressure.

The valve’s opening force is the condensing pressure, which acts on a bellows on the bottom of the valve. The bellows are connected directly to the high side of the refrigeration system through a capillary tube to sense condensing pressure.

As the condensing pressure increases, the valve opens to let more water through the water-cooled condenser. This higher water flow rate will lower the condensing pressure to the set spring pressure.

Looking for quick answers on air conditioning, heating and refrigeration topics? Try Ask ACHR NEWS, our new smart AI search tool. Ask ACHR NEWS →

Conditions that could cause the water-regulating valve to throttle more open and cause an increased water flow through the condenser could be an overcharge of refrigerant, high evaporator loads from warm incoming sump water, a high ambient around the machine, or a fouled condenser, to mention a few.

If condensing pressure decreases, the bellows pressure will be lower and the spring will throttle the valve to a more closed position. Thus, the condensing pressure will again remain constant at varying system conditions.

Conditions that would cause the water-regulating valve to throttle more closed could be an undercharge of refrigerant, cold sump water entering the evaporator at the end of an ice-making cycle, colder inlet water temperatures to the machine, or a cold ambient around the ice machine.

Varying system conditions in this experiment were an overcharge and undercharge of refrigerant. The water-regulating valve reacted by either increasing or decreasing flow through the water-cooled condenser to maintain the set condensing pressure of 225 psig (98°F). The only change in the system was a larger flow of water through the condenser in the overcharged system, and a smaller flow of water for the undercharged system.

These changes are often gone unnoticed by service technicians.

Subcooling, superheat

Condenser subcooling pretty much remained the same for the critical, overcharged, and undercharged systems.

Remember that the water-regulating valve allowed for increased water flow through the water cooled-condenser on the refrigerant overcharge. This increased water flow absorbed more heat from the greater amount of liquid that formed in the condenser from the overcharge of refrigerant.

The decreased water flow through the condenser for the undercharge did not have to absorb as much heat because of less liquid in the condenser. This explains why the subcooling pretty much remained constant in all three scenarios.

The two metering devices in this ice machine were nonadjustable TXVs. A TXV’s function is to keep a constant amount of superheat in the evaporator under all heat-loading conditions. The TXV can do this only if it is supplied with 100% liquid and system pressures do not exceed the operating range of the TXV.

In this experiment, the operating pressure ranges of the TXV were not exceeded in the overcharge or undercharge of refrigerant because constant condensing pressures were held with the water-regulating valve. Also, the undercharge of refrigerant was not severe enough to starve the system of liquid.

The receiver in the system (upper left in Figure 2) helped store subcooled liquid from the condenser to supply to the TXVs when needed. A more severe undercharge may have taken the 100% liquid away from the TXVs and hampered their ability to keep a constant superheat.

Since the suction lines were approximately the same length and were insulated (Figure 2), the compressor superheats remained pretty much the same.

This ice machine is considered a very forgiving machine simply because of its ability to handle an array of varying system conditions and charges and still make quality ice. The fact that it has a water-regulating valve, TXVs, a water-cooled condenser, and a receiver on a critical-charged system gives it the ability to be quite a bit forgiving.

In this experiment, no differences in ice quantity were noticed even when a 5-oz overcharge and undercharge were observed in the system when compared to the critical charge of refrigerant. The undercharge of 5 oz was not enough to starve an evaporator and cause a high evaporator superheat condition, thus less ice.

Even though the water-cooled condenser adds to the quietness and compactness of the system, one must remember that the increased water flow through the condenser on the overcharged system may be objectionable to some owners because of cost and/or availability of water in certain regions.

Share This Story

Looking for a reprint of this article?
From high-res PDFs to custom plaques, order your copy today!

 

Recommended Content

JOIN TODAY
To unlock your recommendations.

Already have an account? Sign In

  • HVAC-enrollment

    The Trades Are Back: HVACR Programs See Nearly 30% Enrollment Spike

    A new wave of future technicians is entering the pipeline.  
    News
    By: Matt Jachman
  • 2025 Top 40 Under 40

    2025 Top 40 Under 40 HVACR Professionals List

    The 11th annual Top 40 Under 40 list highlights those...
    HVAC Contracting
    By: Hannah Belloli-Oster
  • LG Ductless Mini-Split Systems

    The 9 Types of Heat Pumps

    As the U.S. moves toward electrification, heat pumps are...
    HVAC Commercial Market
    By: Joanna R. Turpin
Subscription Center
  • Create an Account
  • Start a Subscription
  • Manage My Account
  • Sign Up for Newsletters
  • Visit Customer Service
  • Update Preferences

More Videos

Sponsored Content

Sponsored Content is a special paid section where industry companies provide high quality, objective, non-commercial content around topics of interest to The News audience. All Sponsored Content is supplied by the advertising company and any opinions expressed in this article are those of the author and not necessarily reflect the views of The News or its parent company, BNP Media. Interested in participating in our Sponsored Content section? Contact your local rep!

close
  • Piggy Bank
    Sponsored byWatercress Financial

    Energy Prices, Inflation, and HVAC: What Today’s Homeowners Care About

  • Refrigerated Food
    Sponsored bySolstice Advanced Materials

    R-455A Refrigeration: A Cold Storage Solution for the Future

  • Airex Rooftop Units
    Sponsored byAirex Manufacturing Inc

    Consolidating Roof Penetrations: A Growing Trend in Multifamily HVAC Design

Popular Stories

HVAC-Price-Increase-graphic

HVAC Price Increase List: June 2026

Trump-Section-232.jpg

Trump Reduces Section 232 Tariffs on HVAC Equipment to 15%

R410A-Refrigerant-Cylinder.jpg

Refrigerant Recovery is a Revenue Opportunity

Heat-pump-cutaway.jpg

PFAS Rules and A2L Building Codes Continue to Evolve

Kroger.jpg

Kroger to Spend $100 Million to Reduce Refrigerant Leaks

View The ACHR NEWS
Centennial Anniversary Timeline

The ACHR News Timeline Chart
Submit a Letter
Submit a letter to our editors.

Events

November 6, 2025

Next-Gen Data Center Cooling: HVAC Innovation and Real-World Solutions

On Demand As AI workloads and high-density computing push traditional cooling methods to their limits, the data center industry is accelerating the adoption of next-generation HVAC technologies.

June 17, 2026

Decarbonization Without Disruption

This webinar will explore practical HVAC decarbonization strategies that minimize disruption while maximizing long-term performance and ROI.

View All Submit An Event

Poll

Summer Staff

Are you fully staffed for the summer season?
View Results Poll Archive

Products

BNI Mechanical/Electrical Square Foot Costbook, 2026 Edition

BNI Mechanical/Electrical Square Foot Costbook, 2026 Edition

See More Products
Decarbonization Without Disruption - Free Webinar - 6/17/2026

Related Articles

  • Wednesday, Jan. 23, 2008: A Very Vento Party

    See More
  • Btu Buddy 4: Cleaning A Very Dirty Condenser

    See More
  • John Tomczyk

    The Professor: The Importance of a Refrigeration System’s Operating Pressures

    See More

Related Products

See More Products
  • comfortcoolingdvd.jpg

    COMFORT COOLING REFRIGERATION SYSTEM TROUBLESHOOTING

  • Soldering and Brazing Refrigeration System Tubing.jpg

    Soldering and Brazing Refrigeration System Tubing DVD

  • Understanding TXV Refrigeration Systems: Superheat and Subcooling DVD

See More Products
×

Sign Up. Stay Informed.

The #1 trusted source for the HVACR industry since 1926

SUBSCRIBE
  • RESOURCES
    • Advertise
    • Contact Us
    • Advisory Board
    • Classifieds
    • Submit a Letter
    • Directories
    • Store
  • ACCOUNT CENTER
    • Create an Account
    • Start a Subscription
    • Manage My Account
    • Sign Up for Newsletters
    • Visit Customer Service
    • Update Preferences
  • SERVICES
    • Marketing Services
    • Reprints
    • Market Research
    • List Rental
    • Survey/Respondent Access
  • STAY CONNECTED
    • LinkedIn
    • Facebook
    • Instagram
    • YouTube
    • X (Twitter)
  • PRIVACY
    • PRIVACY POLICY
    • TERMS & CONDITIONS
    • DO NOT SELL MY PERSONAL INFORMATION
    • PRIVACY REQUEST
    • ACCESSIBILITY

Copyright ©2026. All Rights Reserved BNP Media, Inc. and BNP Media II, LLC.

Design, CMS, Hosting & Web Development :: ePublishing