ACHR News
search
Ask ACHR NEWS AI
cart
facebook twitter instagram linkedin youtube
  • Sign In
  • Subscribe
  • Sign Out
  • My Account
ACHR News
  • NEWS
    • Breaking News
    • New HVAC Products
    • Featured Products
    • Manufacturer Reports
    • HVAC Data
    • Legislation
    • ACHR NEWS Centennial
  • RESIDENTIAL
    • Air Conditioners
    • Furnaces
    • Residential Heat Pumps
    • Ductless
    • Residential IAQ
    • Testing, Monitoring, Tools
    • Components & Accessories
  • COMMERCIAL
    • Air Handlers
    • Rooftop Units
    • Chillers and Cooling Towers
    • Commercial Heat Pumps
    • Boilers and Hydronics
    • VRF/Ductless
    • Commercial IAQ
  • REFRIGERATION
    • Refrigerants
    • Refrigerant Regulations
    • Leak Management
  • CONTRACTOR PRO
    • Geothermal
    • Homeowner Study
    • VRF and VRV Ductless
    • Unitary Trends
  • EDUCATION
    • Training and Education
    • Business Management
    • Service and Maintenance
    • Continuing Education
    • Market Research >
      • HVAC Brand Awareness Report
      • VRV, VRF, VRVZ Report
      • Unitary Trends Report
      • Water Heat Professionals Report
    • Webinars
    • Sponsor Insights
    • eProducts Info
    • White Papers
  • EVENTS
    • HVAC Contractor Forum
    • Industry Events and Webinars
  • MEDIA
    • Videos
    • AHR Expo 2025 Videos
    • Podcasts >
      • ACHR News Podcast
      • HARDI Podcasts
      • AHR Expo Podcasts
      • ACCA Podcasts
    • Interactive Spotlights
    • Quizzes
    • eBooks
    • HVAC Talkback
  • HVAC GROUP
    • ACHR NEWS >
      • Current Issue
      • Digital Edition
      • Subscribe
    • Distribution Trends
    • SNIPS NEWS >
      • Join SNIPS NEWS
    • Engineered Systems News >
      • Join ES News
    • HVACR Directory
    • Contests
    • Newsletters
    • Contact
    • Advertise
    • My Account
Indoor Air QualityHumidification and Dehumidification

A Case of Unforeseen Consequences

By Leonard A. Greene, PE, C. Michael Underhill, CIH, CSP
August 6, 2012
Sometimes we do things with one goal in mind and find that we get the opposite, unintended result. Such experiences have been all too frequent in my consulting practice in a coastal environment. In the process of trying to do a better job of controlling indoor residential humidity, we actually can make the situation worse. In fact, many times things get so bad, occupants are forced to move out and expensive remediation is required.

ASHRAE recommends we keep our indoor humidity below 60 percent and our thermostat at or above 75˚F for indoor summer comfort. New high-end residential equipment is designed to make 75˚ more comfortable by offering a dehumidification option. We are much more comfortable with 55 percent relative humidity (rh) than 65 percent, given the same sensible temperature of say 75˚. Weathermen call this the “real feel” temperature. Plus, lower humidity prevents mold from spawning. So great — we can now control temperature and humidity, and most of the time the theory works.

New variable-speed equipment can operate in dehumidification mode by lowering the fan speed. This in turn slows airflow over the coil, allowing more moisture to be removed. Typically the system goes into dehumidification mode at the beginning and end of a cycle calling for cooling based on thermostat set points. For example, a rise in room temperature causes a call for cooling. If the rh is above the set point, the cooling process starts and ends with operation in dehumidification mode. The fan ramps up, slowly holding at a few hundred feet-per-minute velocity, condensing moisture out of the air very effectively. After a set period of time, the fan accelerates to full speed to deliver designed cfm cool air to the space to satisfy the latent load. Of course moisture continues to be removed during this process.

So far, so good. Once we have the sensible and latent loads satisfied, the unit cycles off. But, what if we have not reached the rh setting? This is when things get interesting. The unit does not cycle off. Rather it cycles back into dehumidification mode. Now we are back to slow air flow, coil temperature drops off a cliff, and so does discharge air temperature. A typical LAT/RAT delta-T can double from 15 degrees to 30 degrees. The unit continues to over-ride sensible settings trying to reach the rh setting until we get 2-3 degrees below the set point. This can take longer since we have less air mixing given the slower flow. Only when either the room is sub-cooled to the maximum allowed, or rh drops below the set point, does the unit cycle off. Meanwhile, we have sub-cooled air flowing in ductwork and supply registers, which are typically metal. This cold air discharges against building materials at the supplies, causing condensation when the unit shuts off and warmer air comes into contact with these surfaces.

The Envelope

Now we need to take a look at how the system interacts with its environment. Here we’re mostly concerned with ductwork and its location. If our duct is in conditioned space, there usually is no problem. But, typically ducts are in unconditioned attic or crawl spaces. So we potentially have R-6 or R-8 nominal insulation intended to separate air with a delta -T of 30-60 degrees difference in an uninsulated attic space. (e.g. supply air at 55˚ and attic temperature of 115˚). With the sub-cooled dehumidification mode air, we can see our delta T driven to over 70˚. As a result, our insulation begins to sweat.

This can also happen in a crawl space without a large delta-T. If the typical foil-jacket vapor barrier is torn or insulation seams have separated, condensation is frequently found starting on the duct as water vapor follows vector forces moving inside the vapor barrier opening. As this water accumulates inside the duct insulation in a crawl space, it collects on the bottom of the insulation blanket and cannot escape. As a result, we get more and more cold water accumulating inside the insulation, resulting in more thermal runaway. The bottom of the duct sweats as the insulation loses its R-value. As the water continues to accumulate in the insulation we have catastrophic loss of R-value bringing the exterior of the insulation below dew point conditions and sub-cooling the adjacent structure resulting in building materials dropping below dew point.

Continued water accumulation spreads in a building structure and subfloor, eventually reaching the finished floor and causing cupping, swelling, and eventual buckling. As this moisture moves from wet to dry, thermal and moisture runaway accelerates, and water ponds on the vapor barrier as well. We see mold growing in the crawl space on building materials but so far we have not had intrusion of spores into the living space. Wrong.

Negative Indoor Conditions

Looking for quick answers on air conditioning, heating and refrigeration topics? Try Ask ACHR NEWS, our new smart AI search tool. Ask ACHR NEWS →

Suppose the supply ductwork leaks and we lose 5 percent or more of our supply air. Typically, return static pressures are lower and there are fewer connections so let’s assume we are returning 100 percent of system air. In our exemplar home we have over 10 tons of capacity.

For a nominal 400 cfm-per-ton, we are losing at least 200 cfm. Add bath and kitchen exhaust, as well as dryer and range hood, and the house really begins to suck. And, as the house goes negative, air in the attic space is being heated, expanded, and becomes more positively pressurized. Warm humid air begins to move into the house from the attic via all available penetrations. Examples include ceiling penetrations for fixtures and bath fans, wall switches, and penetrations for registers including floor registers. Water vapor moves from wet to dry so we also have moisture moving from the attic toward the living space. Gypsum wallboard is transparent to moisture, so where there is no vapor barrier more moisture enters the living space. We are now losing control of humidity.

Moisture and Mold Runaway

Now the situation gets ugly. Warm, moist air infiltrates penetrations. It also condenses against the insulation paper facing a vapor retarder, where it comes into contact with the cooler room temperature sheetrock. The problem is especially acute near supply registers, where temperatures drop sharply below dew point conditions. The insulation paper facing gets saturated, in turn wetting the wallboard or subfloor. The warm, moist air entering penetrations contacts indoor surfaces below the dew point and condenses. As conditions worsen, the area becomes wetter and indoor rh rises. The equipment is running in dehumidification mode as long as controls allow. Instead of lowering rh, as intended, the dehumidification mode sub-cooling makes matters worse by lowering temperatures even further below dew point conditions. Now, we are experiencing a runaway nightmare. Wet gets wetter and rh rises beyond the point of no return. Obvious evidence of water damage worsens and, of course, with it comes the inevitable mold.

Mold

Mold spores require a food source and sufficient moisture to grow. Building materials, particularly cellulose based products, provide excellent nutrients for molds to grow indoors. All that is needed now is sufficient moisture for mold spores to grow and colonize the wet building materials. Mold will begin to actively grow within 24- to 48-hours when sufficient moisture is present.

The kinds of molds that grow depend on the amount of water present and the duration of wet conditions. Some molds require relatively low moisture levels, while others require persistently moist conditions.

Condensation in crawlspaces and attics may cause mold colonization on building materials. Indoor air quality is subsequently significantly degraded because attic and crawlspace air moves into the occupied areas of a building carrying with it mold spores. Air sampling conducted when evaluating some of these cases has shown significant amplification of mold spores indoors, particularly in water-damaged buildings. Overall, levels of mold spores are detected in excess of 15 times higher indoors when compared to ambient mold spore levels outdoors. Mold spore types usually associated with water-damaged buildings, such as Penicillium/Aspergillus, were as much as 35 times higher indoors when compared to outdoors, in areas where significant mold colonization existed on the back side of drywall.

Other mold types identified in the air include Stachybotrys, which indicates that building materials have been subjected to long-term chronically wet conditions due to repeated condensation.

Surface sampling of visible mold colonization may show Aspergillus growing inside supply ductwork. Penicillum may be found colonizing joists in the crawlspace. Stachybotrys is commonly found colonizing the paper on the HVAC filter on the return side of an air handler. This would indicate high rh in the return air which condensed on the cold fan coil cabinet.

Super-cooled supply air blowing on adjacent wall board causes condensation on the back of drywall, which may lead to the colonization of Stachybotrys on the attic side of drywall.

To control wet conditions and resulting mold colonization on building materials, rh should be controlled and supply air systems should be designed so that air is not discharged on adjacent building materials causing condensation. RH should be controlled in crawlspaces by using adequately insulated ducts, the crawlspaces should be enclosed and dehumidified, and duct leakage should be controlled to prevent negative pressure conditions in the occupied spaces of the building.

We recommend attics also be sealed and insulated at the roof deck in addition to insulation on the ceiling/wall board. Best practice is to also install an attic outdoor air dehumidifier which discharges via supply ductwork, reducing or eliminating negative indoor conditions.

Publication date: 8/6/2012

KEYWORDS: dehumidification humidity mold control

Share This Story

Looking for a reprint of this article?
From high-res PDFs to custom plaques, order your copy today!

 

Leonard A. Greene, PE, is owner of Orbital Engineering and Consulting LLC, Charleston, S.C.

C. Michael Underhill, CIH, CSP, is president of Elysium Environmental Services Ltd., Summerville, S.C.

Recommended Content

JOIN TODAY
To unlock your recommendations.

Already have an account? Sign In

  • HVAC-enrollment

    The Trades Are Back: HVACR Programs See Nearly 30% Enrollment Spike

    A new wave of future technicians is entering the pipeline.  
    Training and Education
    By: Matt Jachman
  • 2025 Top 40 Under 40

    2025 Top 40 Under 40 HVACR Professionals List

    The 11th annual Top 40 Under 40 list highlights those...
    HVAC Light Commercial Market
    By: Hannah Belloli-Oster
  • LG Ductless Mini-Split Systems

    The 9 Types of Heat Pumps

    As the U.S. moves toward electrification, heat pumps are...
    HVAC Commercial Market
    By: Joanna R. Turpin
Subscription Center
  • Create an Account
  • Start a Subscription
  • Manage My Account
  • Sign Up for Newsletters
  • Visit Customer Service
  • Update Preferences

More Videos

Sponsored Content

Sponsored Content is a special paid section where industry companies provide high quality, objective, non-commercial content around topics of interest to The News audience. All Sponsored Content is supplied by the advertising company and any opinions expressed in this article are those of the author and not necessarily reflect the views of The News or its parent company, BNP Media. Interested in participating in our Sponsored Content section? Contact your local rep!

close
  • Piggy Bank
    Sponsored byWatercress Financial

    Energy Prices, Inflation, and HVAC: What Today’s Homeowners Care About

  • Refrigerated Food
    Sponsored bySolstice Advanced Materials

    R-455A Refrigeration: A Cold Storage Solution for the Future

  • Airex Rooftop Units
    Sponsored byAirex Manufacturing Inc

    Consolidating Roof Penetrations: A Growing Trend in Multifamily HVAC Design

Popular Stories

Lennox equipment

Platinum Equity to Sell Heat Controller to Lennox

HVAC-tech-van.jpg

Report: Only 65% of HVAC Technician Time is Billable Hours

HVAC Minute retail refrigeration system

EPA Final Rule’s Impact on R-410A Deadlines

Lovato-refrigerant-rooftop_AC_Units_.jpg

When Refrigerants Change, So Do the Contactors

Dealer_Couple2_Kitchen_Estimate.jpg

Predicting the Next Service Call

View The ACHR NEWS
Centennial Anniversary Timeline

The ACHR News Timeline Chart
Submit a Letter
Submit a letter to our editors.

Events

November 6, 2025

Next-Gen Data Center Cooling: HVAC Innovation and Real-World Solutions

On Demand As AI workloads and high-density computing push traditional cooling methods to their limits, the data center industry is accelerating the adoption of next-generation HVAC technologies.

July 28, 2026

How Top Home Services Companies Turn Every Conversation Into Predictable Revenue

In this webinar, we'll outline how top contractors are turning every conversation into predictable revenue by coaching every comfort advisor visit, not just the ones a manager rides along on.

View All Submit An Event

Poll

Summer Staff

Are you fully staffed for the summer season?
View Results Poll Archive

Products

BNI Mechanical/Electrical Square Foot Costbook, 2026 Edition

BNI Mechanical/Electrical Square Foot Costbook, 2026 Edition

See More Products
Designing Systems Using A2L Refrigerant - Free Webinar - 7/22/2026

Related Articles

  • A Case Of Deja  Vu

    See More
  • AHUs contribute to a case of alchemy at Dallas service center

    See More
  • The Case Of The Exhausted Exhaust: A Lab Ventilation Mystery

    The Case Of The Exhausted Exhaust: A Lab Ventilation Mystery

    See More

Related Products

See More Products
  • Lessons Learned in a Boiler Room: A common sense approach to servicing and installing commercial boilers

  • EHEP002028.jpg

    Principles of Heating, Ventilation, and Air Conditioning in Buildings, 1st Edition

  • 0071829598.jpeg

    HVAC Equations, Data, and Rules of Thumb, Third Edition

See More Products

Related Directories

  • Webstone, a brand of NIBCO

    Residential and commercial valves used in plumbing, hydronic, radiant, solar and geothermal applications. Designs focus on labor and space saving concepts that simplify future maintenance.
  • FARO, a business of Ametek Inc.

    FARO develops portable 3D laser scanning devices designed to capture and deliver as-built information into the digital world for building, infrastructure and surveying documentation. FARO's hardware and software solutions allow users to work with Building Information Modeling (BIM) during the design, construction and operation phases to improve productivity, sustainability and quality.
×

Sign Up. Stay Informed.

The #1 trusted source for the HVACR industry since 1926

SUBSCRIBE
  • RESOURCES
    • Advertise
    • Contact Us
    • Advisory Board
    • Classifieds
    • Submit a Letter
    • Directories
    • Store
  • ACCOUNT CENTER
    • Create an Account
    • Start a Subscription
    • Manage My Account
    • Sign Up for Newsletters
    • Visit Customer Service
    • Update Preferences
  • SERVICES
    • Marketing Services
    • Reprints
    • Market Research
    • List Rental
    • Survey/Respondent Access
  • STAY CONNECTED
    • LinkedIn
    • Facebook
    • Instagram
    • YouTube
    • X (Twitter)
  • PRIVACY
    • PRIVACY POLICY
    • TERMS & CONDITIONS
    • DO NOT SELL MY PERSONAL INFORMATION
    • PRIVACY REQUEST
    • ACCESSIBILITY

Copyright ©2026. All Rights Reserved BNP Media, Inc. and BNP Media II, LLC.

Design, CMS, Hosting & Web Development :: ePublishing