the NEWS
Advertisement:
HVACR Directory | Extra Edition | Learning Center | Editorial Blogs | Product Gallery
  Home
  About the NEWS
  Subscription Info
  e-Newsletters
  Contact Us
  Resources
  Archived Editorial
  Blogs
  Career Center - Employers
  Career Center - Job Seekers
  Columns
  Distributor Corner
  Calendar of Events
  HVACR Directory
  Industry Links
  Learning Center
  Letters
  Manufacturer Reports
  Regional Reports
  Reprints
  Survey Says
  Training Track
  Webinars
  AEC Store
  Market Research
  Extra Edition
  HVACR Forum
  Legal forum
  Business Management
  Dot Comment
  Energy Matters
  Features
  Newsline
  People
  Service Hotline
  Service & Maintenance
  Technical
  Advertising
  Ad Index
  Media Kit
  Submit Press Release
  Services
  Classifieds
  Digital Edition
  Post Cards
Search in: EditorialProductsCompanies
Applying Fibrous Glass Duct Wrap

April 3, 2006

ARTICLE TOOLS
EmailEmailPrintPrintReprintsReprintsshareShare



Fibrous glass duct wrap with FSK facing


This article addresses the specific uses, performance characteristics, fire safety, condensation control, and installation recommendations for fibrous glass duct wrap.


USES

Fibrous glass duct wrap insulation is designed for application to the exteriors of commercial and residential sheet metal heating, ventilating, and air conditioning ducts and plenums operating at temperatures between 40°F (4°C) and 250°F (121°C). Duct wrap insulation reduces heat loss or gain through duct walls, conserving energy and controlling moisture condensation. Fibrous glass duct wrap insulations are useful in situations where acoustical performance is not an issue.


DESCRIPTION



Fibrous glass duct wrap insulations are flexible, resilient, light-density blankets of glass fibers factory-laminated to vapor retarder facings. These products are easily cut and fitted to achieve a neat, thermally effective insulation blanket over the exteriors of rectangular, round, oval, or irregularly shaped duct surfaces. They are available in a range of R-values depending on product type, thickness, and density.


FEATURES AND BENEFITS

Condensation control
When installed thickness recommendations are followed, fibrous glass duct wrap insulation installed over sealed sheet metal ducts reduces the likelihood of condensation occurring on the vapor retarder facing, and of moisture damage to ceilings and other interior finishes.


Figure 1. Required R-values to prevent moisture condensation.


Enhanced comfort control
By reducing heat loss or gain through duct walls, conditioned air reaches occupied spaces at temperatures close to design conditions. Central air equipment may therefore be operated at reduced levels, saving energy.


Flexible, easily installed
Fibrous glass duct wrap insulation is easily cut to proper fit. For ease of application, a staple flap is provided by the manufacturers.


Code compliance
Fibrous glass duct wrap insulations meet the physical property requirements of ASTM C 1290 as well as meeting the fire safety requirements of NFPA 90A and 90B including limited combustibility. They also comply with all widely used model codes including ICC, BOCA, CABO, ICBO, and SBCCI.


ASSURED THERMAL PERFORMANCE

When installed in accordance with manufacturers’ instructions, fibrous glass duct wraps will provide specified thermal performance as printed on the vapor retarder facing. This is achieved by determining the “stretch-out” cutting dimension required so that, once installed, the duct wrap is not compressed to less than 75 percent of nominal (out-of-package) thickness.


Figure 2. Installing fibrous glass duct wrap insulation to assure full installed R-value.


Commonly available installed R-values as published by manufacturers show fibrous glass duct wrap insulations to perform in the R-value ranges shown in Table 1.


CONDENSATION CONTROL

Figure 1 shows the installed R-values of fibrous glass duct wrap required to prevent moisture condensation on the vapor retarder surface under varying conditions of ambient temperature and relative humidity. Curves are based on cold duct internal temperatures of 55°F (13°C) and no air movement on the external surface.

Note: R-values as required by ASHRAE 90.1-1989 may not be sufficient for condensation control as may be seen in Figures 1 and 2.



INSTALLATION



Fibrous glass duct wrap insulations are installed with facings away from the duct surface. See Figure 2. A stapling flap, prepared at the time of installation, overlapping the insulation and facing at the other end of the piece of duct wrap, is stapled to form a longitudinal seam. Where a vapor retarder is required, the seam is sealed with pressure-sensitive tape. Adjoining duct wrap sections are similarly stapled and sealed using the facing flap on one edge of the duct wrap as produced at the factory. Seams and joints may also be sealed with mastic and glass fiber fabric.

For complete installation details, consult the manufacturer or National Commercial and Industrial Insulation Standards, 1999, 5th Edition, Midwest Insulation Contractors Association (MICA).





Dimensions in Table 2 are established by ASTM C 1290 and should be used when cutting duct wrap insulation so that, once installed, it is not compressed to less than 75 percent of nominal (out-of-package) thickness.

Reprinted with permission from the North American Insulation Manufacturers Association’s (NAIMA’s) Insulation Facts #66: Fibrous Glass Duct Wrap. NAIMA is the association for North American manufacturers of fiberglass, rock wool, and slag wool insulation products. For more information, visit www.naima.org