search
Ask ACHR NEWS AI
cart
facebook twitter instagram linkedin youtube
  • Sign In
  • Subscribe
  • Sign Out
  • My Account
  • NEWS
  • TECHNOLOGY
    • Heating & Boilers
    • Cooling & Chillers
    • Pumps & Flow Controls
  • SECTORS
    • Commercial
    • Health Care
    • Data Center
    • Educational Facilities
  • DESIGN | CONSTRUCTION
  • OTHER TOPICS
    • High-Performance Buildings & Automation
    • Ventilation and IAQ
    • Commissioning
    • HVAC Retrofits
  • TODAY’S BOILER
    • Today’s Boiler Archives
    • Today’s Boiler Digital Edition
  • MORE
    • Case Studies
    • Podcasts
    • Videos
    • Directory
    • Webinars
    • ES NEWS Store
    • White Papers
  • SIGN UP
  • Back to The NEWS
Engineered Systems NEWSHigh-Performance Buildings & AutomationVentilation and IAQ

Single-Zone AHU Trend Analysis – Cooling

By Rebecca T. Ellis, P.E.
Building Automations
February 27, 2012
In this column, I will describe the “issue” disclosed through analysis of the trend graph included in my February, 2012 “Commissioning” column. I will also introduce a new system, show its trend graph, and then leave it up to the reader to discover the operational issue illustrated in the graph. The answer will be given at the start of next month’s column.                                                                                                        
graph

FEBRUARY 2012 TREND LOG ANALYSIS

Last month’s trend graph showed about two weeks of 15-min interval data from the BAS for selected points on a single-zone, constant volume, mixed AHU. The system was equipped with airside economizer capability, heating hot water coil, and chilled water cooling coil for discharge air temperature control. The discharge air temperature setpoint was reset based on space temperature setpoint.

The trend data was from the fall of 2010 when outside air temperatures varied between 30°F to 60°, a good time to observe economizer operation. What the trend graph tells us is that the AHU was providing excellent temperature control. Its discharge air temperature line was tracking nearly identical to its setpoint.

Based on the outside air damper and hot water valve trends, however, the system was not achieving this desired temperature control as efficiently as possible. There were many times when the hot water valve was open as much as 50% or 100% while the outside air damper was not in its minimum position (10%). This means that the hot water was being used to heat more cold outside air than necessary, using more energy than required.

This imprecise control would be nearly impossible to observe without the trend logging capability of the BAS. It is an example of how the power of DDC can and should change the way building operators manage and evaluate their systems. Correcting the control system programming should be a low-cost energy conservation opportunity requiring neither hardware nor installation labor; the challenge is knowing that it needs to be done. That is where proactive trend log analysis comes in handy.

 

NEW SYSTEM

This month’s trend graph is of the same type of single-zone, constant volume, mixed AHU with airside economizer, heating hot water coil, and chilled water cooling coil for discharge air temperature control. The discharge air temperature setpoint is reset based on space temperature setpoint. This graph has a selected number of points with two different vertical axes (one on the left and one on the right) to help see and evaluate the pertinent points more easily than with a single shared axis.

 

TRENDS

The BAS was used to trend the following sensor and device data at 15-min intervals for a little more than three weeks in the fall of 2011:

 

 

 

Left Hand Vertical Axis:

• Mixed air (outside air) damper command (blue)

• Heating valve command (magenta)

 

Right Hand Vertical Axis:

• Outside air temperature (gray)

• Mixed air temperature (orange)

• Discharge air temperature setpoint (purple)

• Discharge air temperature (green) ES

Share This Story

Looking for a reprint of this article?
From high-res PDFs to custom plaques, order your copy today!

 

Rebecca is president of Questions & Solutions Engineering, Inc. She can be reached at rteesmag@qseng.com

Recommended Content

JOIN TODAY
To unlock your recommendations.

Already have an account? Sign In

  • HVAC-enrollment

    The Trades Are Back: HVACR Programs See Nearly 30% Enrollment Spike

    A new wave of future technicians is entering the pipeline.  
    News
    By: Matt Jachman
  • 2025 Top 40 Under 40

    2025 Top 40 Under 40 HVACR Professionals List

    The 11th annual Top 40 Under 40 list highlights those...
    News
    By: Hannah Belloli-Oster
  • LG Ductless Mini-Split Systems

    The 9 Types of Heat Pumps

    As the U.S. moves toward electrification, heat pumps are...
    HVAC Commercial Market
    By: Joanna R. Turpin

More Videos

Today's Boiler

Spring 2026 Issue

Today's Boiler - Spring 2026 Cover

Read More from Today's Boiler

Case in Point Logo

Smarter Hydronic Design for Data Centers - Free Webinar - January 22, 2026

Related Articles

  • Commissioning

    Single-Zone AHU Trend Analysis

    See More
  • Commissioning Logo

    Art StorageVault AHU Trend Analysis

    See More
  • Air Handling Unit

    Public Art Gallery AHU Trend Analysis

    See More

Related Products

See More Products
  • The ACHR News - December 15 2025

    ACHR NEWS December 15, 2025, Issue

See More Products

Events

View AllSubmit An Event
  • September 9, 2025

    How Maintenance Plays into the HVAC Decarbonization Trend

    On Demand This webinar will explore maintenance strategies for advanced HVAC systems, including VAVs and demand-controlled ventilation.
View AllSubmit An Event

Related Directories

  • ColdZone

    ColdZone, a division of HTPG, delivers green refrigeration technologies and manufactures evaporators, single- and multi-circuit compressor units, and defrost controls designed for foodservice industry.
  • Zero Zone Inc.

    Commercial reach-in display refrigerators and freezers, commercial and industrial refrigeration systems, mechanical and electrical centers. Specialists in natural refrigerant technology.
  • Zone Air

    Based in Salt Lake City, Utah. We specialize in DIY HVAC solutions for homeowners and professionals.
×

Sign Up. Stay Informed.

The #1 trusted source for the HVACR industry since 1926

SUBSCRIBE
  • RESOURCES
    • Advertise
    • Contact Us
    • Advisory Board
    • Classifieds
    • Submit a Letter
    • Directories
    • Store
  • ACCOUNT CENTER
    • Create an Account
    • Start a Subscription
    • Manage My Account
    • Sign Up for Newsletters
    • Visit Customer Service
    • Update Preferences
  • SERVICES
    • Marketing Services
    • Reprints
    • Market Research
    • List Rental
    • Survey/Respondent Access
  • STAY CONNECTED
    • LinkedIn
    • Facebook
    • Instagram
    • YouTube
    • X (Twitter)
  • PRIVACY
    • PRIVACY POLICY
    • TERMS & CONDITIONS
    • DO NOT SELL MY PERSONAL INFORMATION
    • PRIVACY REQUEST
    • ACCESSIBILITY

Copyright ©2026. All Rights Reserved BNP Media, Inc. and BNP Media II, LLC.

Design, CMS, Hosting & Web Development :: ePublishing