WEST LAFAYETTE, IN — Hydrocarbons (HCs) may not make much of an impact in the United States — then again, they just may. Nevertheless, it’s safe to say that they are gaining more and more attention most everywhere else as a refrigerant.

The latest wave of overseas research is experimentation in pulling CFC, HCFC, and HFC refrigerants out of a variety of systems and seeing what happens when HCs are used instead.

“While HCs do not always offer the higher COP [coefficient of performance] for the four categories considered, over half of the cases showed a mean improvement of up to 10%. An appreciable proportion of the cases showed an improvement of between 10% to 20%,” according to data gathered by Calor Gas, Ltd. and University College, London. “Overall, approximately 90% of the cases did reveal better performance.”

The report did note the focus was on HCs vs. CFCs and HCFCs, rather than HFCs. A caution flag went up over use of butane/ propane blends in domestic refrigerators, propane in air conditioners, and isobutane in heat pumps.

Looking at specific hydrocarbons relative to R-22, it was noted that hydrocarbon R-1270 and a proprietary blend of R-170/R-290 “offer favorable reductions in approach temperature differences, both evaporator and condenser, [and] benefits in terms of pressure loss and compressor COP.”



Heat Pump, Refrigeration

Specific heat pump work was reported on by scientists from Italy, Spain, Sweden, and Switzerland.

A medium-size air-to-water heat pump was converted from R-22 for use with propane (R-290). Among the findings:

  • A reduction of refrigerant charge of more than 65% compared to the charge of R-22.
  • The capacity in heating as well as cooling mode is expected to be similar compared to the R-22 commercial heat pump.
  • An increase higher than 10% in COP at central test conditions in both heating and cooling mode is predicted.
  • A technology institute in Brazil wanted to compare HC-600a and HFC-134a in commercial freezers. Testing was done on an ice cream cabinet. “An experimental investigation has indicated the technical feasibility of using HC-600a based on improved performance,” according to conclusions. Reduced energy consumption and lower internal air temperature were noted with 600a. The project has now gone from lab research to field-testing.

    Scientists from the University of Jordan took a 2.5-ton split system air conditioner and replaced its R-22 with butane and propane in different ratios.

    The report noted, “All investigated hydrocarbon mixtures can be used as possible alternative refrigerants to R-22 with COP values that are competitive with R-22 values.”

    It was further noted that “The 100% propane mixture had the highest COP values among all the hydrocarbons tested. The 90% propane mixture is selected to be the most suitable alternative refrigerant to R-22 based on both higher COP and equal saturated pressure match.”

    Finally, the report contended that such changes could be done “with no modifications or adjustments to [units] designed for R-22. No problems have been encountered with the compressor. No degradation of lubricating oil could be detected after the refrigerator worked for 1,000 hours using the same oil.”

    Publication date: 10/02/2000

    Did you enjoy this article? Click here to subscribe to The NEWS Magazine

    Recent Articles by Peter Powell

    You must login or register in order to post a comment.

    Multimedia

    Videos

    Image Galleries

    2014 Energy Efficiency Forum

    Highlights from the 25th annual Energy Efficiency Forum in Washington, D.C.

    Podcasts

    NEWSMakers: Jeremy Begley

    Jeremy Begley, home-performance specialist and Web and social media manager with National Heating and Air Conditioning Co. in Cincinnati discusses how and why you should add home-performance philosophies to your contracting repertoire. Posted on Sept. 12.

    More Podcasts

    ACHRNEWS

    NEWS 09-15-14 cover

    2014 September 15

    Check out the weekly edition of The NEWS today!

    Table Of Contents Subscribe

    Venting R-22

    The NEWS reported that a man received prison time for venting R-22. Should EPA step up enforcement?
    View Results Poll Archive

    HVACR INDUSTRY STORE

    plumbing-hvac.gif
    2014 National Plumbing & HVAC Estimator

    Every plumbing and HVAC estimator can use the cost estimates in this practical manual!

    More Products

    Clear Seas Research

     

    Clear Seas ResearchWith access to over one million professionals and more than 60 industry-specific publications, Clear Seas Research offers relevant insights from those who know your industry best. Let us customize a market research solution that exceeds your marketing goals.

    DON'T MISS A THING

    Magazine image
     
    Register today for complete access to ACHRNews.com. Get full access to the latest features, Extra Edition, and more.

    STAY CONNECTED

    facebook icontwitter iconyoutube iconLinkedIn i con