ACHR News
search
Ask ACHR NEWS AI
cart
facebook twitter instagram linkedin youtube
  • Sign In
  • Subscribe
  • Sign Out
  • My Account
ACHR News
  • NEWS
    • Breaking News
    • New HVAC Products
    • Featured Products
    • Manufacturer Reports
    • HVAC Data
    • Legislation
    • ACHR NEWS Centennial
  • RESIDENTIAL
    • Air Conditioners
    • Furnaces
    • Residential Heat Pumps
    • Ductless
    • Residential IAQ
    • Testing, Monitoring, Tools
    • Components & Accessories
  • COMMERCIAL
    • Air Handlers
    • Rooftop Units
    • Chillers and Cooling Towers
    • Commercial Heat Pumps
    • Boilers and Hydronics
    • VRF/Ductless
    • Commercial IAQ
  • REFRIGERATION
    • Refrigerants
    • Refrigerant Regulations
    • Leak Management
  • CONTRACTOR PRO
    • Geothermal
    • Homeowner Study
    • VRF and VRV Ductless
    • Unitary Trends
  • EDUCATION
    • Training and Education
    • Business Management
    • Service and Maintenance
    • Continuing Education
    • Market Research >
      • HVAC Brand Awareness Report
      • VRV, VRF, VRVZ Report
      • Unitary Trends Report
      • Water Heat Professionals Report
    • Webinars
    • Sponsor Insights
    • eProducts Info
    • White Papers
  • EVENTS
    • HVAC Contractor Forum
    • Industry Events and Webinars
  • MEDIA
    • Videos
    • AHR Expo 2025 Videos
    • Podcasts >
      • ACHR News Podcast
      • HARDI Podcasts
      • AHR Expo Podcasts
      • ACCA Podcasts
    • Interactive Spotlights
    • Quizzes
    • eBooks
    • HVAC Talkback
  • HVAC GROUP
    • ACHR NEWS >
      • Current Issue
      • Digital Edition
      • Subscribe
    • Distribution Trends
    • SNIPS NEWS >
      • Join SNIPS NEWS
    • Engineered Systems News >
      • Join ES News
    • HVACR Directory
    • Contests
    • Newsletters
    • Contact
    • Advertise
    • My Account

Ohio City Tests Electric Discharge Bypass Valves

By Joanna R. Turpin
May 22, 2000
The city of Independence loves its EDBVs. The valves minimize equipment stress and compressor failures. In addition, energy consumption of the retrofitted units has been reduced due to the elimination of excessive starting and stopping.
INDEPENDENCE, OH — Located just south of Cleveland, this little town recently had a problem finding a way to precisely control the environment in its diverse city complex.

The recently constructed Civic Center relied on a 37-ton DX, vav air conditioning system, which serviced several large meeting rooms, a kitchen, and a small amphitheater.

The system was designed to handle the area under a heavy load of people, lighting, and kitchen use. Many times only one room was in use out of the entire area (usually a small group of people having a meeting). The large condensing unit was able, through unloading, to reduce the system capacity to approximately 12 tons of cooling.

A conventional mechanical hot gas bypass was installed at the air handler DX coil, and an AHU controller regulated the discharge air to the vav boxes at 55°F. A variable-speed drive controlled the air handler motor speed based on static pressure created by demand of the vav boxes.

The problem occurred on mild days with minimal load. “The condenser unit would start and within about one minute, the air handler discharge temperature would drop well below the desired 55° temperature, causing the condenser unit to cycle off on low limit.

“No matter what we tried with control strategies, the room was either too warm or too cold under minimal load conditions,” says Rick Casentini, director of technical services, Independence, Ohio.

Due to the rapid cycling of the condensing unit, proper dehumidification was impossible. It was discovered that the root of the problem was the mechanical bypass valve, which was unable to respond in time to the actual load conditions — not passing enough hot gas to overcome the low pressure and temperatures at the air handler. So Casentini asked Jeffrey Caldwell, J.J. Caldwell Mechanical Inc., Breckenridge, CO, who was a technical consultant and application engineer under contract with the City of Independence at the time, to find a solution.

What to Do

Researching various options, including some very creative control strategies and variable-speed controlling of the compressor in the condensing unit, didn’t result in any practical solutions.

“We were of the opinion that a proportional digitally controlled valve, which could react immediately to changing pressure and temperature conditions at the evaporator, was needed,” says Casentini.

Looking for quick answers on air conditioning, heating and refrigeration topics? Try Ask ACHR NEWS, our new smart AI search tool. Ask ACHR NEWS →

Unfortunately, Casentini and Caldwell could not locate a manufacturer that produced such a valve. Most manufacturers they contacted indicated that they experienced similar problems with low-load cycling on DX systems; however they stated that the customers just had to live with the problem. Casentini and his staff refused to accept that answer.

At the suggestion of a colleague, Casentini contacted Sporlan Valve, which agreed to discuss the possibility of developing such a valve to be tested in Independence. The first test model valve worked perfectly, says Casentini.

A side loop control program was developed in the existing AHU controller to control the air handler discharge temperature between 54° and 56°. The newly developed valve controlled to within 4¼10 of a degree. After one minor mechanical fault was discovered and corrected, the valve worked perfectly.

EDBVs are motor operated.

So What Are They?

Electronically controlled valves are most often thought of as being electric expansion valves (EEVs). However, advancements in the technology have allowed the EEV to be applied in many other places in the modern refrigeration and air conditioning system.

Typical EEVs were designed to open and close against high-side to low-side pressure drops. In an R-404A system at 100° condensing temperature and -20° evaporator temperature, this is about 220 psi. Given the correct motor power for the port size, this pressure differential is easily overcome, says Brian Dolin, director, Mechatronics Products Group, Sporlan Valve Co., Washington, MO.

“Liquid temperatures are usually in the range of 105° to 40° in expansion valve applications and don’t represent much of a challenge on the materials of construction of the valve or motor. A more demanding application is use as a discharge gas bypass valve,” or DBV.

The pressure drops experienced by DBVs are similar to those seen by TXVs or EEVs, but the temperatures are very different. When mounted close to the compressor, DBVs may have to regulate 230ü gas. Motor materials, synthetic seat and seals, and wire insulation must all be engineered to withstand this environment.

So why would anyone even think of using an electronically controlled valve in this manner? In a word, control, says Dolin.

“Mechanical DBVs are simply pressure regulators. They function by balancing the force of a spring against downstream pressure exerted on a diaphragm. Since the spring must compress and the diaphragm, must deflect to allow the port to open, all mechanical DBVs have hysteresis and gradient.”

(Hysteresis is the friction force of bending of the spring and diaphragm and usually causes the valve to close “easier” than it opens. This creates a gradient, meaning that the valve cannot control to an exact pressure under all flow conditions.)

Typical mechanical DBVs allow a 6° temperature change in the evaporator across their operating range. Precise temperature control with mechanical DBVs is therefore difficult or impossible, says Dolin.

“Electronically controlled DBVs or EDBVs have no gradient. They are electrically driven to a position, precisely and repeatably. This makes direct temperature control with EDBVs not only possible but also easy.”

EDBVs can be controlled with a sensor or transducer.

Better Control a Benefit

Mechanical DBVs are not used as temperature controls but rather as capacity controls. As load on the system drops, evaporator pressure drops which, in turn, strokes the DBV open. The hot gas is used to falsely load the evaporator and compressor to keep it on-line.

EDBVs, on the other hand, can be controlled with a temperature sensor or a pressure transducer. By mounting the temperature sensor in the air off the evaporator or in the outlet stream of chilled water, the EDBV will react with the proper amount of hot gas to both load the compressor and control the temperature directly.

“Our experience with process cooling manufacturers has shown that control on the order of plus or minus 0.1° is easily achieved. Some of our customers manufacture chillers for use in the medical, plastics, or instrumentation fields, where reliable sources of precisely controlled water for cooling are critical. No other system they have tried has been as simple, inexpensive and reliable as the EDBV with controller,” says Dolin.

Simple to Select and Install

Selecting an EDBV is really not that difficult. Unlike some mech-anical DBVs, EDBVs may be used with any refrigerant, provided the materials are compatible.

EDBVs are motor operated and are therefore not reliant on the pressure-temperature relationship of the refrigerant. The five factors used for selecting an EDBV are: refrigerant, desired outlet fluid temperature, compressor capacity at minimum allowable evaporator temperature, minimum evaporator load, and condensing temperature at minimum load.

Unlike mechanical valves, says Dolin, oversizing an EDBV is not generally harmful. “If oversized by as much as 100%, EDBVs can still throttle to maintain setpoint. If undersized, of course, they will not have the capacity to maintain setpoint under fully reduced load.”

In addition, EDBVs are designed as cartridge-type valves; that is, all moving parts are replaced as a unit, and the body remains inline during service. Field problems seen with EDBVs have usually been related to abuse and contaminants more than any other cause. The good news is that EDBVs and other electric valves are more tolerant of dirt and can be commanded to open to purge contaminants.

As for the City of Indepen-dence, its administrators are thrilled with the valves. Says Casentini, “These valves have worked excellently in our facilities.

“Equipment stress and compressor failures have been minimized by the application of this product. A side benefit has been reduced energy consumption of the retrofitted units due to the elimination of excessive starting and stopping.”

Share This Story

Looking for a reprint of this article?
From high-res PDFs to custom plaques, order your copy today!

 

Tn joanna 2017
Joanna Turpin is a Senior Editor at The ACHR NEWS. She can be contacted at 248-786-1707 or joannaturpin@achrnews.com. Joanna has been with BNP Media since 1991, first heading up the company’s technical book division before moving over to The ACHR NEWS, where she frequently writes about refrigerants and commercial refrigeration. She obtained her bachelor’s degree in English from the University of Washington and worked on her master’s degree in technical communication at Eastern Michigan University.

Recommended Content

JOIN TODAY
To unlock your recommendations.

Already have an account? Sign In

  • HVAC-enrollment

    The Trades Are Back: HVACR Programs See Nearly 30% Enrollment Spike

    A new wave of future technicians is entering the pipeline.  
    Training and Education
    By: Matt Jachman
  • 2025 Top 40 Under 40

    2025 Top 40 Under 40 HVACR Professionals List

    The 11th annual Top 40 Under 40 list highlights those...
    HVAC Residential Market
    By: Hannah Belloli-Oster
  • LG Ductless Mini-Split Systems

    The 9 Types of Heat Pumps

    As the U.S. moves toward electrification, heat pumps are...
    HVAC Residential Market
    By: Joanna R. Turpin
Subscription Center
  • Create an Account
  • Start a Subscription
  • Manage My Account
  • Sign Up for Newsletters
  • Visit Customer Service
  • Update Preferences

More Videos

Sponsored Content

Sponsored Content is a special paid section where industry companies provide high quality, objective, non-commercial content around topics of interest to The News audience. All Sponsored Content is supplied by the advertising company and any opinions expressed in this article are those of the author and not necessarily reflect the views of The News or its parent company, BNP Media. Interested in participating in our Sponsored Content section? Contact your local rep!

close
  • Piggy Bank
    Sponsored byWatercress Financial

    Energy Prices, Inflation, and HVAC: What Today’s Homeowners Care About

  • Refrigerated Food
    Sponsored bySolstice Advanced Materials

    R-455A Refrigeration: A Cold Storage Solution for the Future

  • Airex Rooftop Units
    Sponsored byAirex Manufacturing Inc

    Consolidating Roof Penetrations: A Growing Trend in Multifamily HVAC Design

Popular Stories

Lennox equipment

Platinum Equity to Sell Heat Controller to Lennox

Trade groups challenge EPA refrigerant rule

HVACR Trade Groups Challenge EPA Refrigerant Rule in Federal Court

heat-pump-tech-customer.jpg

DOE Updates $8.8B Home Energy Rebate Program Guidance

Lovato-refrigerant-rooftop_AC_Units_.jpg

When Refrigerants Change, So Do the Contactors

Martin Hoover

ACCA Leadership Shakeup: Barton James Out, Hoover Named Interim CEO

View The ACHR NEWS
Centennial Anniversary Timeline

The ACHR News Timeline Chart
Submit a Letter
Submit a letter to our editors.

Events

November 6, 2025

Next-Gen Data Center Cooling: HVAC Innovation and Real-World Solutions

On Demand As AI workloads and high-density computing push traditional cooling methods to their limits, the data center industry is accelerating the adoption of next-generation HVAC technologies.

July 28, 2026

How Top Home Services Companies Turn Every Conversation Into Predictable Revenue

In this webinar, we'll outline how top contractors are turning every conversation into predictable revenue by coaching every comfort advisor visit, not just the ones a manager rides along on.

View All Submit An Event

Poll

Summer Staff

Are you fully staffed for the summer season?
View Results Poll Archive

Products

BNI Mechanical/Electrical Square Foot Costbook, 2026 Edition

BNI Mechanical/Electrical Square Foot Costbook, 2026 Edition

See More Products
Designing Systems Using A2L Refrigerant - Free Webinar - 7/22/2026

Related Articles

  • Trane CCHP Prototype

    Trane Set to Start Field Tests of Cold Climate Heat Pumps

    See More
  • Specifying valves ain’t like it used to be

    See More
  • Storming The Windy City

    See More

Related Products

See More Products
  • Troublingshooting-Servicing-Electric-Furnances-211x300.jpg

    Troubleshooting & Servicing Electric Furnances

  • Troublingshooting-Servicing-Electric-Furnances-211x300.jpg

    Troubleshooting & Servicing Electric Furnances

See More Products

Related Directories

  • Valves Only

    Valves Only is a trusted Alloy 20 Valve Manufacturers in USA, High-quality, corrosion-resistant solutions for industries dealing with acidic and corrosive environments. Our Alloy 20 valves are made to withstand harsh conditions and are intended for use in chemical and marine industries.
  • Hex Valve

    Instrumentation and gauge valves, manifold valves.
×

Sign Up. Stay Informed.

The #1 trusted source for the HVACR industry since 1926

SUBSCRIBE
  • RESOURCES
    • Advertise
    • Contact Us
    • Advisory Board
    • Classifieds
    • Submit a Letter
    • Directories
    • Store
  • ACCOUNT CENTER
    • Create an Account
    • Start a Subscription
    • Manage My Account
    • Sign Up for Newsletters
    • Visit Customer Service
    • Update Preferences
  • SERVICES
    • Marketing Services
    • Reprints
    • Market Research
    • List Rental
    • Survey/Respondent Access
  • STAY CONNECTED
    • LinkedIn
    • Facebook
    • Instagram
    • YouTube
    • X (Twitter)
  • PRIVACY
    • PRIVACY POLICY
    • TERMS & CONDITIONS
    • DO NOT SELL MY PERSONAL INFORMATION
    • PRIVACY REQUEST
    • ACCESSIBILITY

Copyright ©2026. All Rights Reserved BNP Media, Inc. and BNP Media II, LLC.

Design, CMS, Hosting & Web Development :: ePublishing