ACHR News
search
Ask ACHR NEWS AI
cart
facebook twitter instagram linkedin youtube
  • Sign In
  • Subscribe
  • Sign Out
  • My Account
ACHR News
  • NEWS
    • Breaking News
    • New HVAC Products
    • Featured Products
    • Manufacturer Reports
    • HVAC Data
    • Legislation
    • ACHR NEWS Centennial
  • RESIDENTIAL
    • Air Conditioners
    • Furnaces
    • Residential Heat Pumps
    • Ductless
    • Residential IAQ
    • Testing, Monitoring, Tools
    • Components & Accessories
  • COMMERCIAL
    • Air Handlers
    • Rooftop Units
    • Chillers and Cooling Towers
    • Commercial Heat Pumps
    • Boilers and Hydronics
    • VRF/Ductless
    • Commercial IAQ
  • REFRIGERATION
    • Refrigerants
    • Refrigerant Regulations
    • Leak Management
  • CONTRACTOR PRO
    • Geothermal
    • Homeowner Study
    • VRF and VRV Ductless
    • Unitary Trends
  • EDUCATION
    • Training and Education
    • Business Management
    • Service and Maintenance
    • Continuing Education
    • Market Research >
      • HVAC Brand Awareness Report
      • VRV, VRF, VRVZ Report
      • Unitary Trends Report
      • Water Heat Professionals Report
    • Webinars
    • Sponsor Insights
    • eProducts Info
    • White Papers
  • EVENTS
    • HVAC Contractor Forum
    • Industry Events and Webinars
  • MEDIA
    • Videos
    • AHR Expo 2025 Videos
    • Podcasts >
      • ACHR News Podcast
      • HARDI Podcasts
      • AHR Expo Podcasts
      • ACCA Podcasts
    • Interactive Spotlights
    • Quizzes
    • eBooks
    • HVAC Talkback
  • HVAC GROUP
    • ACHR NEWS >
      • Current Issue
      • Digital Edition
      • Subscribe
    • Distribution Trends
    • SNIPS NEWS >
      • Join SNIPS NEWS
    • Engineered Systems News >
      • Join ES News
    • HVACR Directory
    • Contests
    • Newsletters
    • Contact
    • Advertise
    • My Account

Money leaking from the mechanical room: A practical guide to addressing chiller leaks

January 25, 1999
The U.S. Environmental Protection Agency published a proposed rule in Fall 1997 to reduce the emission limits for chillers and industrial process refrigerant equipment. This rule may become law under the U.S. Clean Air Act (CAA).

The ruling will reduce allowable emission rates from 5% to 15%, depending on the application (see Table 1).

There will be discussion on how to define new vs. existing chiller leak rates, and how to distinguish between leaks during system operation and repair.

This ruling refocuses the industry’s efforts on containment practices and improving refrigeration chiller designs for the future.

As demonstrated in Table 2, leak rates in the industry have dramatically improved in new designs.

In the past, leaking chillers were tolerated due to readily available supply and cost.

Today, if a refrigerant charge is lost, the cost can be substantial (see Table 3).

For example, a typical 500-ton CFC chiller that becomes overpressurized due to a system malfunction could result in a $29,000 R-12 replacement expense. Unlike the past, that incident could also cost building owners and managers downtime on a process, or downtime for the building itself — a cost that certainly would exceed the refrigerant cost.

This is money leaking from the mechanical room.

Also, under the Clean Air Act, if a leak occurs, building owners and managers have 30 days to correct the leak or develop a dated retrofit-retirement plan, and complete all actions detailed in the plan within one year from the plan date. Beyond that, if detected, they can be fined $25,000 per day per incident under the Clean Air Act regulations.

Looking for quick answers on air conditioning, heating and refrigeration topics? Try Ask ACHR NEWS, our new smart AI search tool. Ask ACHR NEWS →

Not only is this costly, but embarrassing, as EPA has released examples of violations to the press.

What Actions Should Facility Owners Take?

Referring back to Table 2, leak rates can be reduced to 0.5% to 2% on new equipment. On older installed equipment, reducing the leak rates to 2% to 5% is possible with close attention to proper “containment.”

With a negative-pressure chiller (old CFC-11 or newer HCFC-123 chillers), as noted in Table 2, the leak rates historically have been high. Although these chillers operate below atmospheric pressure on the cooler side of the unit, they are operating well above atmospheric pressure in the condenser and compressor.

This results in a critical leak path of sucking air and moisture into the cooler, which adds to corrosion and loss of refrigerant from the condenser and compressor.

Why do manufacturers of these chillers allow a design of this type? Simply stated, the customer did not want to pay for upgraded containment in the past. For example, these negative-pressure chillers were supplied to the market with standard purge units to purge out the air and moisture that leaked into the cooler.

However, on these standard units, for every 1 lb of non-condensables (air and/or moisture) that was purged, between 3 to 20 lb of refrigerant were exhausted.

Today, very high-efficiency purge systems that significantly lower this emission, along with improved containment equipment (see Table 4), are available. Remote refrigerant storage tanks are available for serving negative-pressure chillers, as the construction of negative-pressure chillers does not allow for internal storage during service.

A special notation should be made that external storage and transfer pump units are required by the U.S. Clean Air Act during service. These storage and transfer units must meet the requirements of the U.S. Clean Air Act for evacuation levels in removing refrigerant, and also must comply with standard ARI-740 as a recycle-reclaim device.

Does this law require that an owner of equipment must purchase a storage-transfer unit? No. However, the agency servicing the chiller must supply certified equipment during the service.

It is highly recommended that if the chiller is larger than 300 tons of refrigeration, that the owner purchase a storage tank. Forcing a service agency to bring smaller, multiple tanks on-site to store the refrigerant results in increased risk of emissions during transfer, and increases the potential for a refrigerant spill.

Also, at that nominal level and above the refrigerant charge (approximately 720 lb), removal may result in a long transfer period and an increase in potential leaks.

More Accessories

Back-up relief valves are excellent devices that prevent the loss of refrigerant in a chiller.

The standard pressure-relief device on a negative-pressure CFC-11 or HCFC-123 chiller is a carbon disk with a 0.03-in. membrane, which shatters at 15 psig. Any overpressurization results in total loss of the refrigerant.

Back-up relief valves have been created to lower this loss during overpressurization. These back-up devices contain non-fragmenting disks with a reseating plunger that will relieve the pressure and then reseat. This saves a good portion of the refrigerant that was lost. These devices typically cost $3,800, which may vary with installation costs.

When you consider that a total loss of CFC-11 or HCFC-123 on a 500-ton chiller could result in a refrigerant bill of $5,028 (HCFC-123) to $16,836 (CFC-11), the $3,800 back-up valve is a good investment, especially when you consider the potential cost of chiller downtime.

Two other good containment products on the market are pressurizing systems and oil filter-isolation valves.

Pressurizing systems facilitate leak detection on negative-pressure chillers, to ensure the chiller remains below the leak rate requirements of the CAA. Isolation valves allow oil filters to be changed while isolating the main oil circuit, which typically has a considerable amount of entrapped refrigerant.

Piping all of the mentioned containment devices typically will cost an additional $3,000, for a total of $24,700.

This add-on containment is recommended when upgrading or purchasing new negative-pressure chillers. The added cost and installation was considered during the design of the new chillers using HCFC-22 or HFC-134a and, as can be noted in Table 4, was eliminated or built into these chillers.

A key feature of these positive-pressure certified-vessel chillers is the ability to charge the refrigerant into the equipment at the factory and ship them to the construction site. This greatly reduces the emissions, start-up time, and incidents of accidents that could result when charging a chiller on-site.

Also, with the use of isolation valves built into the chiller, refrigerant can be stored in the chiller during service. With best-in-class 0.1% annual leak rates and the ability to store refrigerant in the chiller, the equipment results in an emission-preventable design.

The compressor motor type should be considered in lowering emissions of refrigerants. The industry offers semi-hermetic sealed motors up through 2,000 tons of refrigeration. Above that level, the horsepower requirements dictate that open-drive or separate coupled motors are used. Where the semi-hermetic (hermetically sealed, but serviceable) prevent the loss of refrigerant, open-drive motors will lose approximately 2% of the chiller’s full charge annually.

As refrigerant and oil mix during the chiller operation, any loss of oil results in the loss of refrigerant entrapped in the oil.

On existing open-drive equipment, the placement of a refrigerant detection monitor close to the open-drive seal is an excellent method to indicate both the excessive loss of refrigerant, and as a warning that the seal between the motor and the compressor may have excessive wear and is in need of replacement.

This loss of refrigerant is addressed in ASHRAE Guideline 3-1996, “Shaft Seals are Required on Open Style Compressors and can be a Source of Refrigerant Leakage.” This standard is an excellent reference guide in reducing emissions in air conditioning equipment. Written by a committee of industry experts, the practices addressed in this guideline are the standard to reduce refrigerant emissions.

Stemming The Flow

The money leaking from the mechanical room is not only the loss of the expensive refrigerant, but also the loss of efficiency of the chiller.

In the use of negative-pressure chillers (CFC-11, HCFC-123 designs), this loss of efficiency is a result of the refrigerant leaks, both internally and externally. Negative-pressure chillers have a potential leak path that draws non-condensable air and moisture into the cooler section of the chiller.

For every 1 psi of air that leaks into a negative chiller, a 3% loss of efficiency occurs. As air is a non-condensable product in the chiller, the air will collect in the upper portion of the chiller’s condenser and reduce the effect of the heat exchanger — all the more reason to have a high-efficiency purge to remove these non-condensables.

Loss of refrigerant through condensers and compressors that operate above atmospheric pressure for all chiller equipment (CFC-11, HCFC-123, CFC-12, HFC-134a) can result in a shortage of refrigerant to provide the proper heat transfer in both the cooler and condenser as the optimum refrigerant charge is lowered.

Also, in negative-pressure chillers, the air and moisture leaking into the chiller can combine to produce oil foaming in the cooler, due to both the leaks and the migration of oil from the compressor during part-load capacity. This foaming of oil can result in an 8% loss in cooler efficiency as the foaming blankets the upper heat-transfer portion of the cooler.

When you consider that a negative-pressure chiller is purchased at a specific efficiency level and then can degrade by as much as 12% due to system leaks, prevention of these leaks will lower your power bill. A review of your refrigeration chiller equipment should be addressed.

The importance of leak prevention and specification of advanced designs is critical to ensuring that money is not leaking from the mechanical room.

Jim Parsnow is director of environmental systems marketing for Carrier Corp., and can be contacted at 315-433-4376; 315-432-7836 (fax); jim.pars now@carrier.utc.com (e-mail).

Share This Story

Looking for a reprint of this article?
From high-res PDFs to custom plaques, order your copy today!

 

Recommended Content

JOIN TODAY
To unlock your recommendations.

Already have an account? Sign In

  • HVAC-enrollment

    The Trades Are Back: HVACR Programs See Nearly 30% Enrollment Spike

    A new wave of future technicians is entering the pipeline.  
    Training and Education
    By: Matt Jachman
  • 2025 Top 40 Under 40

    2025 Top 40 Under 40 HVACR Professionals List

    The 11th annual Top 40 Under 40 list highlights those...
    HVAC Contracting
    By: Hannah Belloli-Oster
  • LG Ductless Mini-Split Systems

    The 9 Types of Heat Pumps

    As the U.S. moves toward electrification, heat pumps are...
    Heat Pumps
    By: Joanna R. Turpin
Subscription Center
  • Create an Account
  • Start a Subscription
  • Manage My Account
  • Sign Up for Newsletters
  • Visit Customer Service
  • Update Preferences

More Videos

Sponsored Content

Sponsored Content is a special paid section where industry companies provide high quality, objective, non-commercial content around topics of interest to The News audience. All Sponsored Content is supplied by the advertising company and any opinions expressed in this article are those of the author and not necessarily reflect the views of The News or its parent company, BNP Media. Interested in participating in our Sponsored Content section? Contact your local rep!

close
  • Piggy Bank
    Sponsored byWatercress Financial

    Energy Prices, Inflation, and HVAC: What Today’s Homeowners Care About

  • Refrigerated Food
    Sponsored bySolstice Advanced Materials

    R-455A Refrigeration: A Cold Storage Solution for the Future

  • Airex Rooftop Units
    Sponsored byAirex Manufacturing Inc

    Consolidating Roof Penetrations: A Growing Trend in Multifamily HVAC Design

Popular Stories

HVAC-Price-Increase-graphic

HVAC Price Increase List: June 2026

Trump-Section-232.jpg

Trump Reduces Section 232 Tariffs on HVAC Equipment to 15%

R410A-Refrigerant-Cylinder.jpg

Refrigerant Recovery is a Revenue Opportunity

Heat-pump-cutaway.jpg

PFAS Rules and A2L Building Codes Continue to Evolve

Kroger.jpg

Kroger to Spend $100 Million to Reduce Refrigerant Leaks

View The ACHR NEWS
Centennial Anniversary Timeline

The ACHR News Timeline Chart
Submit a Letter
Submit a letter to our editors.

Events

November 6, 2025

Next-Gen Data Center Cooling: HVAC Innovation and Real-World Solutions

On Demand As AI workloads and high-density computing push traditional cooling methods to their limits, the data center industry is accelerating the adoption of next-generation HVAC technologies.

June 17, 2026

Decarbonization Without Disruption

This webinar will explore practical HVAC decarbonization strategies that minimize disruption while maximizing long-term performance and ROI.

View All Submit An Event

Poll

Summer Staff

Are you fully staffed for the summer season?
View Results Poll Archive

Products

BNI Mechanical/Electrical Square Foot Costbook, 2026 Edition

BNI Mechanical/Electrical Square Foot Costbook, 2026 Edition

See More Products
A2L Refrigerants - Free Webinar - May 21, 2026

Related Articles

  • A Practical Guide for Preparing for the Unexpected

    A Practical Guide for Preparing for the Unexpected

    See More
  • Business owner

    Stablecoins and the Future of HVAC Business Payments: A Practical Guide for Business Owners

    See More
  • FDA Building

    A Guide to Developing a Practical Perspective on Building Decarbonization

    See More

Related Products

See More Products
  • Lessons Learned in a Boiler Room: A common sense approach to servicing and installing commercial boilers

  • quick guide.png

    Quick Guide to Refrig Cycle, Refrigerants, Components

  • Optimizing Social Media from a B2B Perspective

See More Products

Events

View AllSubmit An Event
  • October 30, 2025

    The HVAC Contractor’s Guide to AI-Driven SEO

    On Demand We will provide a clear, actionable roadmap for HVAC contractors to enhance their online visibility, dominate local search results, and adapt to the new era of AI-driven customer inquiries. Learn how to turn clicks into profitable calls and secure your position as the go-to HVAC provider in your area.
View AllSubmit An Event

Related Directories

  • Spectronics Corp./Spectroline Leak Detection

    Established in 1955, Spectronics Corporation is the inventor of UV fluorescent leak detection technology and manufacturer of leak detection tools for AC&R systems. Our fluorescent dyes and system additives are OEM-grade, universal (POE), co-solvent free, and NSF-certified.
×

Sign Up. Stay Informed.

The #1 trusted source for the HVACR industry since 1926

SUBSCRIBE
  • RESOURCES
    • Advertise
    • Contact Us
    • Advisory Board
    • Classifieds
    • Submit a Letter
    • Directories
    • Store
  • ACCOUNT CENTER
    • Create an Account
    • Start a Subscription
    • Manage My Account
    • Sign Up for Newsletters
    • Visit Customer Service
    • Update Preferences
  • SERVICES
    • Marketing Services
    • Reprints
    • Market Research
    • List Rental
    • Survey/Respondent Access
  • STAY CONNECTED
    • LinkedIn
    • Facebook
    • Instagram
    • YouTube
    • X (Twitter)
  • PRIVACY
    • PRIVACY POLICY
    • TERMS & CONDITIONS
    • DO NOT SELL MY PERSONAL INFORMATION
    • PRIVACY REQUEST
    • ACCESSIBILITY

Copyright ©2026. All Rights Reserved BNP Media, Inc. and BNP Media II, LLC.

Design, CMS, Hosting & Web Development :: ePublishing