ACHR News
search
Ask ACHR NEWS AI
cart
facebook twitter instagram linkedin youtube
  • Sign In
  • Subscribe
  • Sign Out
  • My Account
ACHR News
  • NEWS
    • Breaking News
    • New HVAC Products
    • Featured Products
    • Manufacturer Reports
    • HVAC Data
    • Legislation
    • ACHR NEWS Centennial
  • RESIDENTIAL
    • Air Conditioners
    • Furnaces
    • Residential Heat Pumps
    • Ductless
    • Residential IAQ
    • Testing, Monitoring, Tools
    • Components & Accessories
  • COMMERCIAL
    • Air Handlers
    • Rooftop Units
    • Chillers and Cooling Towers
    • Commercial Heat Pumps
    • Boilers and Hydronics
    • VRF/Ductless
    • Commercial IAQ
  • REFRIGERATION
    • Refrigerants
    • Refrigerant Regulations
    • Leak Management
  • CONTRACTOR PRO
    • Geothermal
    • Homeowner Study
    • VRF and VRV Ductless
    • Unitary Trends
  • EDUCATION
    • Training and Education
    • Business Management
    • Service and Maintenance
    • Continuing Education
    • Market Research >
      • HVAC Brand Awareness Report
      • VRV, VRF, VRVZ Report
      • Unitary Trends Report
      • Water Heat Professionals Report
    • Webinars
    • Sponsor Insights
    • eProducts Info
    • White Papers
  • EVENTS
    • HVAC Contractor Forum
    • Industry Events and Webinars
  • MEDIA
    • Videos
    • AHR Expo 2025 Videos
    • Podcasts >
      • ACHR News Podcast
      • HARDI Podcasts
      • AHR Expo Podcasts
      • ACCA Podcasts
    • Interactive Spotlights
    • Quizzes
    • eBooks
    • HVAC Talkback
  • HVAC GROUP
    • ACHR NEWS >
      • Current Issue
      • Digital Edition
      • Subscribe
    • Distribution Trends
    • SNIPS NEWS >
      • Join SNIPS NEWS
    • Engineered Systems News >
      • Join ES News
    • HVACR Directory
    • Contests
    • Newsletters
    • Contact
    • Advertise
    • My Account

How to inspect, maintain chiller barrels

September 18, 2000
Chillers big and small call for maintenance to protect equipment investment. Key components, like chiller barrels and condensers, must run and run and run, with unfailing dependability and performance.

Like other components in a system, evaporators are normally quite reliable. However, periodic inspections and proper maintenance are essential to help sustain system design capacity, dependability, and long service life.

Most service contractors are well informed about water quality-related problems that can affect condensers. This is due in part to the fact that condenser water is normally circulated in an open system with cooling towers — or even pond or river water in some instances.

As such they are, in general, more susceptible to corrosion, fouling, and mineral deposition than chiller barrels. Minerals, slime, sludge, and microorganisms are often inherent in water, in reasonably acceptable concentrations. However, these contaminants can often be concentrated to unacceptable levels due to insufficient tower water bleed and inadequate fresh water makeup.

While water problems of chillers are generally not as dramatic as those for condensers, they do demand attention.

Chilled water for air conditioning, which normally circulates in a closed-loop system, should be monitored closely. For chilled water in process cooling systems, it is essential.

Depending upon the application, chiller barrel performance can be highly prone to poor water quality. Many process water cooling systems have large reservoirs, auxiliary sumps, cooling troughs, spray systems, and large piping systems.

When compared to air conditioning, chilled water for process cooling can create extraordinary water quality problems, including high exposure to airborne dust, dirt, and other particulate matter.

Looking for quick answers on air conditioning, heating and refrigeration topics? Try Ask ACHR NEWS, our new smart AI search tool. Ask ACHR NEWS →

Here are some vital chiller barrel inspection and service procedures to help keep customers and their products cool during peak loads. For obvious reasons, air conditioning system inspections are best performed at the end of the cooling season.

But, first, a little background on water quality, coolant problems, and other potentially destructive operating conditions that can result in lost chiller barrel performance and reduced service life.

Destructive conditions

“Early retirement” of key system components, such as chiller barrels or condensers, is not an option for most building owners due to costly repairs and downtime.

Remember, there are no short cuts to proper chiller barrel inspections. Periodic maintenance is the only way to ensure peak heat transfer, energy efficiency, and longer operating life for the entire packaged chiller.

Make sure there’s cool, clean water. Fouling due to poor water quality can result in gradual but significant reductions in chiller barrel performance and/or reduced service life.

While a small amount of scaling is normal and will even help protect the tubes from corrosion, excessive hard scale from water with high mineral content can severely inhibit heat transfer and increase pressure drop.

While scale can be removed with acid, improper acid cleaning can shorten the life of the chiller barrel. So having good water quality early on can be vital to chiller barrel performance and service life.

Sediment from airborne matter, heavy rust, and other system-related sources can also result in significant performance losses — even freeze-ups if build-up severely restricts water flow. Sediment problems are easily remedied by installing and maintaining strainers or filters on chiller barrel inlet water.

Large accumulations of sediment can be readily removed by backflushing or reverse flow. Sediment agitation and removal can be enhanced by injecting low-pressure air at 25 to 50 psig with a nozzle into the coupling on the flange where water is being pumped through.

For air conditioning, the best time to perform this work is after seasonal shutdown. Maintenance for process cooling is generally required during line shutdown.

Be alert to changes in chilled water acidity. Chilled water or ethylene glycol solutions do not necessarily remain chemically stable and neutral throughout the system’s lifecycle. Recirculated chilled water and other brines can become corrosive over time, and attack and destroy internal baffles.

Performance reductions of 50% to 60% can occur due to the fact that the baffles, designed to promote turbulent fluid flow to the tube surface for optimum heat transfer, will no longer function properly.

Additionally, corrosive water can attack copper tubes and create leaks. Proper monitoring of water conditions is essential, and is best performed by laboratory analysis.

Your water samples should be run for Langelier and Ryznar indexes at professional local labs. Depending upon test results, it may be necessary to use corrosion inhibitors, or drain and flush the entire system and add fresh, clean water.

Some manufacturers now offer test kits for mail order analysis. Specially designed fluid-testing packages are available for a wide range of heat transfer fluids analyses, including water, oil, and refrigerants. (Standard Refrigeration offers standard fluid analysis [SFA] test kits. For more information, use the phone number or website listed at the end of this article.)

Water velocity is the chiller killer. Chiller barrel service life can be cut short by high water velocity. Excessive flow will result in velocities that exceed intended design conditions.

This should be checked at start-up and periodically to ensure that flow does not exceed values recommended by the manufacturer. Use a properly calibrated flow meter.

Do not use pressure drop to calculate flow. Pressure drop will rise after a unit is commissioned, and is therefore an inadequate method of determining flow. The rise in pressure drop is due to deposits and fouling that accumulate during the evaporator’s lifecycle. The pressure drop rise can be several psi above that measured at start-up.

Maintain vital control settings. Proper maintenance of chiller barrels is more than just monitoring fluid quality. Many chillers are needlessly frozen due to control failure or improperly adjusted controls that should also be protected from tampering.

The low-pressure cutout and flow switch deserve special attention. Both controls should be periodically inspected for functionality and proper setpoint to trip the compressor if limits are exceeded.

Low-pressure cutouts should trip slightly above the freezing point of your chiller’s recirculating fluid. Lower settings minimize nuisance tripping, but the trade-off is increased risk of freeze-ups. Additionally, be sure to account for the glide in the new zeotropic refrigerants when determining the proper setting for the low-pressure cutout.

Flow switch settings are equally important to help prevent needless freeze-ups. Settings should be adjusted to trip not only when water flow is completely stopped, but also to monitor any appreciable flow reduction. Settings for either control should always be verified through several operating cycles, using only the most accurate gauges.

Watch out for big chiller barrel troubles. Chiller barrels with excessive performance loss and poor maintenance records can often be restored to useful service life. Depending upon the degree of damage, these units can sometimes be restored to useful service during seasonal shutdown.

If they have accumulated excessive scale formation or have sediment problems, the problem can often be resolved by backflushing or reverse flow.

Tubes damaged by freeze-up or corrosive attacks can be replaced. Flooded chillers, with end caps removed, can be cleaned readily. And DX chillers can be cleaned chemically by using the proper procedures.

Chiller barrels should only be reassembled following the manufacturer’s specifications and put back in service after pressure testing. However, these procedures are costly and time consuming. What better reason for regular inspections and maintenance?

If chiller barrel inspections are performed at least once a year, there will be fewer surprises or needless service interruptions. Experience proves that most potentially damaging operating conditions can be revealed in time for corrective maintenance that is essential to efficient heat exchange and long service life.

Standard Refrigeration is a manufacturer of water-cooled condensers, chiller barrels, subcoolers, receivers, and suction line heat exchangers. For more information, contact the company at 2050 N. Ruby St., Melrose Park, Ill. 60160-1133; 708-345-5400; 708-345-3513 (fax); www. stanref.com (website).

Share This Story

Looking for a reprint of this article?
From high-res PDFs to custom plaques, order your copy today!

 

Recommended Content

JOIN TODAY
To unlock your recommendations.

Already have an account? Sign In

  • HVAC-enrollment

    The Trades Are Back: HVACR Programs See Nearly 30% Enrollment Spike

    A new wave of future technicians is entering the pipeline.  
    News
    By: Matt Jachman
  • 2025 Top 40 Under 40

    2025 Top 40 Under 40 HVACR Professionals List

    The 11th annual Top 40 Under 40 list highlights those...
    HVAC Light Commercial Market
    By: Hannah Belloli-Oster
  • LG Ductless Mini-Split Systems

    The 9 Types of Heat Pumps

    As the U.S. moves toward electrification, heat pumps are...
    Heat Pumps
    By: Joanna R. Turpin
Subscription Center
  • Create an Account
  • Start a Subscription
  • Manage My Account
  • Sign Up for Newsletters
  • Visit Customer Service
  • Update Preferences

More Videos

Sponsored Content

Sponsored Content is a special paid section where industry companies provide high quality, objective, non-commercial content around topics of interest to The News audience. All Sponsored Content is supplied by the advertising company and any opinions expressed in this article are those of the author and not necessarily reflect the views of The News or its parent company, BNP Media. Interested in participating in our Sponsored Content section? Contact your local rep!

close
  • Piggy Bank
    Sponsored byWatercress Financial

    Energy Prices, Inflation, and HVAC: What Today’s Homeowners Care About

  • Refrigerated Food
    Sponsored bySolstice Advanced Materials

    R-455A Refrigeration: A Cold Storage Solution for the Future

  • Airex Rooftop Units
    Sponsored byAirex Manufacturing Inc

    Consolidating Roof Penetrations: A Growing Trend in Multifamily HVAC Design

Popular Stories

HVAC-Price-Increase-graphic

HVAC Price Increase List: June 2026

Trump-Section-232.jpg

Trump Reduces Section 232 Tariffs on HVAC Equipment to 15%

Refrigerants-and-gauge.jpg

HVAC Industry Warns of Counterfeit Refrigerants Entering U.S. Supply Chain

U.S. Supreme Court building

95% Furnace Efficiency Rule to Get New Hearing

Midea-training.jpg

HVAC Workforce Crisis Expands Beyond Technicians to Instructor Shortages

View The ACHR NEWS
Centennial Anniversary Timeline

The ACHR News Timeline Chart
Submit a Letter
Submit a letter to our editors.

Events

November 6, 2025

Next-Gen Data Center Cooling: HVAC Innovation and Real-World Solutions

On Demand As AI workloads and high-density computing push traditional cooling methods to their limits, the data center industry is accelerating the adoption of next-generation HVAC technologies.

June 23, 2026

HVAC Duct Sealing Mastics: Why Selection Matters

In this webinar we will detail what HVAC material buyers and technicians need to know when selecting duct mastics, including matching mastic to substrate, alternatives to liquid mastic, and where UL 181 Listings fit into real world installations.

View All Submit An Event

Poll

Summer Staff

Are you fully staffed for the summer season?
View Results Poll Archive

Products

BNI Mechanical/Electrical Square Foot Costbook, 2026 Edition

BNI Mechanical/Electrical Square Foot Costbook, 2026 Edition

See More Products
HVAC Duct Sealing Mastics: Why Selection Matters - Free Webinar - 6/23/2026

Related Articles

  • How to inspect residential insulation jobs

    See More
  • Frosted evaporator coil.

    Don’t Forget to Inspect and Clean the Evaporator Coil

    See More
  • From the factory floor

    How to maintain and flush steam and hot water heating systems

    See More

Related Products

See More Products
  • front cover only.jpg

    How to Market Your HVAC Business

See More Products

Related Directories

  • Howe Corp.

    Howe manufactures flake ice making equipment for use with virtually any refrigerant including natural such as R-744, and R-717, Ice storage bins, Condensing units for our ice flakers.
  • Condenser and Chiller Services

    Offers in-field eddy current inspection, remote video inspection, protective epoxy coatings and complete retubing service with tubes in stock.
×

Sign Up. Stay Informed.

The #1 trusted source for the HVACR industry since 1926

SUBSCRIBE
  • RESOURCES
    • Advertise
    • Contact Us
    • Advisory Board
    • Classifieds
    • Submit a Letter
    • Directories
    • Store
  • ACCOUNT CENTER
    • Create an Account
    • Start a Subscription
    • Manage My Account
    • Sign Up for Newsletters
    • Visit Customer Service
    • Update Preferences
  • SERVICES
    • Marketing Services
    • Reprints
    • Market Research
    • List Rental
    • Survey/Respondent Access
  • STAY CONNECTED
    • LinkedIn
    • Facebook
    • Instagram
    • YouTube
    • X (Twitter)
  • PRIVACY
    • PRIVACY POLICY
    • TERMS & CONDITIONS
    • DO NOT SELL MY PERSONAL INFORMATION
    • PRIVACY REQUEST
    • ACCESSIBILITY

Copyright ©2026. All Rights Reserved BNP Media, Inc. and BNP Media II, LLC.

Design, CMS, Hosting & Web Development :: ePublishing