Coming to the Defense of HFC's

August 30, 2000
/ Print / Reprints /
ShareMore
/ Text Size+
WEST LAFAYETTE, IN — HFCs are coming in for some criticism overseas over the global warming issue. But several North American sources are coming to those refrigerants’ defense. They are showing ways the industry can respond to the critics.

That was demonstrated with a number of papers presented at the International Refrigeration Conference here at Purdue University.

DuPont Fluoroproducts noted that “HFC compounds generally have lower global warming potential [GWP] value than CFCs.” It noted that “These values are higher than for fluids such as ammonia, hydrocarbons, and carbon dioxide.”

However, the report went on to say, “To minimize the impact of HFCs on climate change, it is important for the industry to continue improving stewardship-in-use practices.” These include “cradle-to-grave management of emissions, equipment designed and operated for reduced HFC emissions, and improved energy efficiency for reduced carbon dioxide emissions.”

In light of scattergun assaults on HFCs from several European governments, agencies, and environmental groups, the DuPont report noted that the high-profile Kyoto Protocol concerning global warming “is based on a ‘basket of gases’ [of which HFCs is only one component], so no single class of gases must be targeted for phaseout.”

The report did say that, “HFCs are prime candidates for reducing net emissions within the basket of gases. At equivalent costs of other options, climate change impact from minimal refrigerant emissions can be more than offset by improved energy efficiency while meeting reliability and safety requirements.”



Reduced Emissions

The report then went on to catalog how the industry has responded over the years to making energy efficiency improvements and reducing refrigerant emissions.

For example, it was noted that energy efficiency ratings of unitary air conditioning in the United States improved from 7 to 10.8 SEER from 1975 to 1995, resulting in a 35% reduction in energy consumption. Data for high-efficiency chillers showed a 33% reduction in energy consumption from 1978 to 1998.

The report also explored progress made in reducing refrigerant leakage, especially in the supermarket sector, long a source of high leak rates. It reported refrigerant loss reductions of 50% to 80% vs. previous operations of traditional supermarkets. DuPont noted moves to distributed systems within stores, as well as the use of secondary-loop systems, as further ways to reduce reliance on refrigerants.



Economizer System

Also reporting on better use of refrigerants was Mobile Climate Control Inc., of North York, ON, Canada, which wanted to know what would happen with economizer technology.

The company set up a system with a closed-loop rotary vane compressor, a condenser unit, the high-pressure side of an economizing heat exchanger, an expansion device, and an evaporator unit. The economizer circuit connected the liquid line after the condenser unit with an economizer port of the compressor. This section comprised an additional expansion device, the low-pressure side of the economizing heat exchanger, and the economizer port itself.

Among the company’s findings:

  • The biggest potential economizing effect is on R-507A and -404A.

  • Ammonia showed the least improvement with the economizer. It was slightly better with R-22. Economizer performances with R-134a, -410A, -407C, and propane were in the middle.



    Efficiency Maximized

    Scientists at the Solar Energy Laboratory of the University of Wisconsin focused the load-sharing strategies in a multiple compressor refrigeration system. The goal was to “identify operating strategies that properly account for compressor unloading characteristics and maximize the efficiency of the entire system.”

    Research was done on an ammonia-based industrial vapor compression system serving a two-temperature level food storage facility near Milwaukee, WI.

    The project report pointed out that “Part-load compressor operation is required in order to balance the refrigeration capacity of the compressors with the refrigeration demand from the system.”

    It further said that “Recipro-cating compressors have near-linear unloading curves and therefore introduce relatively small performance penalties when operated with a low part-load ratios.”

    However, screw compressors “require more power per unit in cooling capacity” when unloaded.

    Powell is refrigeration editor for The News. You may reach him at 847-622-7260; 847-622-7266 (fax); or PowellBNP@aol.com (e-mail).

    Publication date: 09/04/2000

  • Did you enjoy this article? Click here to subscribe to The NEWS Magazine

    Recent Articles by Peter Powell

    You must login or register in order to post a comment.

    Multimedia

    Videos

    Image Galleries

    2014 MCAA Annual Convention

    Scenes from the 2014 MCAA Annual Convention in Scottsdale, Ariz.

    Podcasts

    NEWSmakers: Julian Scadden

    Training is an ongoing process. Julian will discuss how you can generate maximum return on time and energy invested training by following a three part process. Listen to this podcast to get expert tips on training, tracking and follow up. 

    More Podcasts

    THE MAGAZINE

    ACHRNEWS

    NEWS 04-14-14 cover

    2014 April 14

    Check out the weekly edition of The NEWS today!

    Table Of Contents Subscribe

    SERVICE CALLS POLL

    Which statement on service calls best applies to your business?
    View Results Poll Archive

    HVACR INDUSTRY STORE

    plumbing-hvac.gif
    2014 National Plumbing & HVAC Estimator

    Every plumbing and HVAC estimator can use the cost estimates in this practical manual!

    More Products

    Clear Seas Research

     

    Clear Seas ResearchWith access to over one million professionals and more than 60 industry-specific publications, Clear Seas Research offers relevant insights from those who know your industry best. Let us customize a market research solution that exceeds your marketing goals.

    DON'T MISS A THING

    Magazine image
     
    Register today for complete access to ACHRNews.com. Get full access to the latest features, Extra Edition, and more.

    STAY CONNECTED

    facebook icontwitter iconyoutube iconLinkedIn i con