ACHR News
search
Ask ACHR NEWS AI
cart
facebook twitter instagram linkedin youtube
  • Sign In
  • Subscribe
  • Sign Out
  • My Account
ACHR News
  • NEWS
    • Breaking News
    • New HVAC Products
    • Featured Products
    • Manufacturer Reports
    • HVAC Data
    • Legislation
    • ACHR NEWS Centennial
  • RESIDENTIAL
    • Air Conditioners
    • Furnaces
    • Residential Heat Pumps
    • Ductless
    • Residential IAQ
    • Testing, Monitoring, Tools
    • Components & Accessories
  • COMMERCIAL
    • Air Handlers
    • Rooftop Units
    • Chillers and Cooling Towers
    • Commercial Heat Pumps
    • Boilers and Hydronics
    • VRF/Ductless
    • Commercial IAQ
  • REFRIGERATION
    • Refrigerants
    • Refrigerant Regulations
    • Leak Management
  • CONTRACTOR PRO
    • Geothermal
    • Homeowner Study
    • VRF and VRV Ductless
    • Unitary Trends
  • EDUCATION
    • Training and Education
    • Business Management
    • Service and Maintenance
    • Continuing Education
    • Market Research >
      • HVAC Brand Awareness Report
      • VRV, VRF, VRVZ Report
      • Unitary Trends Report
      • Water Heat Professionals Report
    • Webinars
    • Sponsor Insights
    • eProducts Info
    • White Papers
  • EVENTS
    • HVAC Contractor Forum
    • Industry Events and Webinars
  • MEDIA
    • Videos
    • AHR Expo 2025 Videos
    • Podcasts >
      • ACHR News Podcast
      • HARDI Podcasts
      • AHR Expo Podcasts
      • ACCA Podcasts
    • Interactive Spotlights
    • Quizzes
    • eBooks
    • HVAC Talkback
  • HVAC GROUP
    • ACHR NEWS >
      • Current Issue
      • Digital Edition
      • Subscribe
    • Distribution Trends
    • SNIPS NEWS >
      • Join SNIPS NEWS
    • Engineered Systems News >
      • Join ES News
    • HVACR Directory
    • Contests
    • Newsletters
    • Contact
    • Advertise
    • My Account

An engineer's view on need for quality installations

June 1, 2000
As a professional engineer, I perform pre-purchase house inspections for potential home buyers. In this case, I performed a post-purchase inspection of a residence in an upper-middle-income section of Cold Spring Harbor on Long Island in New York.

The owner bought the house about 18 months ago. The house was inspected by a structural engineer who found nothing structurally deficient in the residence. In fact, it was well built and met the standards for construction in the area.

The house was about 45 years old, and was extensively modified about 15 years ago, with a major kitchen renovation. At that time, a central air conditioning system was installed in the home.

Why I was called

I was called in by the present owner, who complained of a musty odor in the house. I told her on the phone that it might be possible to solve the problem with a duct and coil cleaning, but first I would have to investigate to find the problem (or problems, as it soon became apparent).

I went to the house and noted the musty odor. I opened up the return air grille in the ceiling of the second floor and saw a clean fiber glass air filter. The owner recognized that one should replace air filters on a regular basis.

However, it seemed as though the air was coming out of the return duct, not being sucked in. The airflow out of the 12 vents in the ceilings of the first and second floors was very low.

What I later deduced was that the coil was so clogged with dirt, very little airflow was going though the system. That is why it seemed that air was not being sucked into the return duct.

The reason for the clogged evaporator coil was that fiber glass filters were used in the residence, and they are not as effective as paper pleated air filters in collecting airborne dirt.

I noticed that the return duct included duct liner. I thought this was unusual. I did not see any reason to put duct liner in a return duct.

Looking for quick answers on air conditioning, heating and refrigeration topics? Try Ask ACHR NEWS, our new smart AI search tool. Ask ACHR NEWS →

I went into the attic. The surface temperature of the outside of the air-handling system was warm. I knew there had to be duct liner inside the system. There was also duct liner inside the main trunk line, about 8 ft long.

The duct liner in the return duct was filthy, with 15 years of accumulated dirt. It was a porous fiber glass duct liner, with no surface coating to prevent dirt from lodging in the liner. I took out a small sample, about 1/2 in. sq, and showed it to the homeowner. There was a potent odor coming from it.

Off the main trunk line there was about 100 ft of flex duct in the attic. While there was insulation on the floor of the attic, there was no insulation between the rafters in the ceiling, so the attic was very warm.

Therefore, system efficiency was being compromised by having the evaporator coil in a hot location, since every time the air conditioning system came on, it first had to cool down the very warm system in the attic, which was a much higher temperature than the first and second floors.

The ceiling between the first and second floors was opened up about 15 years ago to put in the air conditioning system. The building heat is hydronic hot water baseboard radiation. Thus, the air conditioning system had to be separate from the heating system.

I believe that the ductwork above the sheetrock ceiling on the first floor may be constructed of flex duct. I was unable to verify the conditions, as I could not cut holes in the ceiling to determine what was behind the vents, or to open up a vent. If I had a borescope, I could have looked inside the system.

If there was flex duct in the first-floor ceiling, it would be impossible to clean. The use of flex duct in areas that are inaccessible, and impossible to access for cleaning, should be prohibited in building codes.

There was a supply duct between the first and second floors in a closet. I deemed it sufficiently accessible to allow the duct to be cleaned.

The basement had its own set of problems. It did not have any air conditioning, nor was there a dehumidifier. A musty odor was present in all the textile materials in the basement. I told the homeowner to either clean these materials or throw them out.

There were some old, decrepit sofas that were ready for the trash heap. The oriental rug could be cleaned, but the carpet was in very bad condition.

What the duct cleaner said

I contacted my duct-cleaning contractor that I use for duct and coil cleaning jobs. I told him of the conditions on the first and second floor. He told me that he would not take the job to clean the system. He honestly told me that the age of the system (15 years) and the condition of the duct liner made it impossible to properly clean the system.

He said it was a cheap installation. Duct liner is cheap to install compared with hard metal duct. When duct liner is lodged with dirt, it cannot be properly cleaned. My duct-cleaning company replaces it when they find it in systems.

He told me that about 75% of the residences on Long Island have systems like this house. His recommendation was to replace the entire system in the attic and replace the condenser and compressor unit located on the north face of the building.

I took down nameplate data from the condenser and compressor unit, and contacted the manufacturer. The system EER was 9.3, relatively good for the time, but obsolete by today’s standards, especially in a high-electricity-cost area such as Long Island.

Equipment for residential usage with SEERs as high as 16 is regularly advertised. With the state of the system being as it is, replacement with a more efficient system would probably cut energy costs in half.

My report to the homeowner

I wrote up my report to the homeowner, and told her that a duct cleaning would not be worth the money, as the condition of the system was not worth the effort. There was no guarantee that a duct cleaning could adequately clean the ductwork in the residence, and it would have to be done each year at great cost. It was not worth the effort.

I told her that the entire system, as much as could be accessed, should be replaced. I recommended the installation of a new system with exterior duct insulation. I told her that hard galvanized ductwork should be used throughout the attic.

I explained that the only way to clean the flex duct that may have been present in the ceiling of the first floor was to use a suction vacuum, and the use of a vacuum hose might shred the material to pieces.

Then I gave her a rough cost estimate of the work to be done in the house.

What contractors need to do

Installing contractors need to stop “cutting corners.” Contractors need to understand that they have to install systems that are easy to maintain, inexpensive to operate, and will be usable for the life of the building.

We need to stop putting in inefficient systems.

We need to perform quality work. We need systems that can be easily cleaned when necessary, with galvanized ductwork, exterior duct insulation, and paper pleated filters.

We have to sell owners on the need for a job done right. A poorly designed or cheap job only leads to trouble in the future.

Share This Story

Looking for a reprint of this article?
From high-res PDFs to custom plaques, order your copy today!

 

Recommended Content

JOIN TODAY
To unlock your recommendations.

Already have an account? Sign In

  • HVAC-enrollment

    The Trades Are Back: HVACR Programs See Nearly 30% Enrollment Spike

    A new wave of future technicians is entering the pipeline.  
    Training and Education
    By: Matt Jachman
  • 2025 Top 40 Under 40

    2025 Top 40 Under 40 HVACR Professionals List

    The 11th annual Top 40 Under 40 list highlights those...
    HVAC Contracting
    By: Hannah Belloli-Oster
  • LG Ductless Mini-Split Systems

    The 9 Types of Heat Pumps

    As the U.S. moves toward electrification, heat pumps are...
    HVAC Commercial Market
    By: Joanna R. Turpin
Subscription Center
  • Create an Account
  • Start a Subscription
  • Manage My Account
  • Sign Up for Newsletters
  • Visit Customer Service
  • Update Preferences

More Videos

Sponsored Content

Sponsored Content is a special paid section where industry companies provide high quality, objective, non-commercial content around topics of interest to The News audience. All Sponsored Content is supplied by the advertising company and any opinions expressed in this article are those of the author and not necessarily reflect the views of The News or its parent company, BNP Media. Interested in participating in our Sponsored Content section? Contact your local rep!

close
  • Piggy Bank
    Sponsored byWatercress Financial

    Energy Prices, Inflation, and HVAC: What Today’s Homeowners Care About

  • Refrigerated Food
    Sponsored bySolstice Advanced Materials

    R-455A Refrigeration: A Cold Storage Solution for the Future

  • Airex Rooftop Units
    Sponsored byAirex Manufacturing Inc

    Consolidating Roof Penetrations: A Growing Trend in Multifamily HVAC Design

Popular Stories

Lennox equipment

Platinum Equity to Sell Heat Controller to Lennox

HVAC-tech-van.jpg

Report: Only 65% of HVAC Technician Time is Billable Hours

HVAC Minute retail refrigeration system

EPA Final Rule’s Impact on R-410A Deadlines

Trade groups challenge EPA refrigerant rule

HVACR Trade Groups Challenge EPA Refrigerant Rule in Federal Court

heat-pump-tech-customer.jpg

DOE Updates $8.8B Home Energy Rebate Program Guidance

View The ACHR NEWS
Centennial Anniversary Timeline

The ACHR News Timeline Chart
Submit a Letter
Submit a letter to our editors.

Events

November 6, 2025

Next-Gen Data Center Cooling: HVAC Innovation and Real-World Solutions

On Demand As AI workloads and high-density computing push traditional cooling methods to their limits, the data center industry is accelerating the adoption of next-generation HVAC technologies.

July 28, 2026

How Top Home Services Companies Turn Every Conversation Into Predictable Revenue

In this webinar, we'll outline how top contractors are turning every conversation into predictable revenue by coaching every comfort advisor visit, not just the ones a manager rides along on.

View All Submit An Event

Poll

Summer Staff

Are you fully staffed for the summer season?
View Results Poll Archive

Products

BNI Mechanical/Electrical Square Foot Costbook, 2026 Edition

BNI Mechanical/Electrical Square Foot Costbook, 2026 Edition

See More Products
Designing Systems Using A2L Refrigerant - Free Webinar - 7/22/2026

Related Articles

  • Training for Quality Installations

    See More
  • Dec. 8, 2010: ACCA Publishes New ComforTool Flyer on Need for Outside Air

    See More
  • April 27, 2007: HVACR Alliance Meets With Officials on Need for Skills Training

    See More

Related Products

See More Products
  • Tech_CommRef_Guide_Small.jpg

    Technician’s Guide & Workbook for Quality Maintenance on Commercial Refrigeration Equipment

  • new cover.jpg

    Profit is An Attitude: The Strategies You Need to Optimize Profits

See More Products

Related Directories

  • Quality Engineering Products Corp.

    Capillary, copper tubing, cold controls, copper fittings, contactors, fan blades, hard start kits, motors, thermostats, timer defrost controls, transformers, vibration eliminators.
  • Association for Facilities Engineering-AFE

    AFE provides education, certification, technical information and other relevant resources for plant and facilities operations, engineering and maintenance professionals worldwide.
×

Sign Up. Stay Informed.

The #1 trusted source for the HVACR industry since 1926

SUBSCRIBE
  • RESOURCES
    • Advertise
    • Contact Us
    • Advisory Board
    • Classifieds
    • Submit a Letter
    • Directories
    • Store
  • ACCOUNT CENTER
    • Create an Account
    • Start a Subscription
    • Manage My Account
    • Sign Up for Newsletters
    • Visit Customer Service
    • Update Preferences
  • SERVICES
    • Marketing Services
    • Reprints
    • Market Research
    • List Rental
    • Survey/Respondent Access
  • STAY CONNECTED
    • LinkedIn
    • Facebook
    • Instagram
    • YouTube
    • X (Twitter)
  • PRIVACY
    • PRIVACY POLICY
    • TERMS & CONDITIONS
    • DO NOT SELL MY PERSONAL INFORMATION
    • PRIVACY REQUEST
    • ACCESSIBILITY

Copyright ©2026. All Rights Reserved BNP Media, Inc. and BNP Media II, LLC.

Design, CMS, Hosting & Web Development :: ePublishing