ACHR News
search
Ask ACHR NEWS AI
cart
facebook twitter instagram linkedin youtube
  • Sign In
  • Subscribe
  • Sign Out
  • My Account
ACHR News
  • NEWS
    • Breaking News
    • New HVAC Products
    • Featured Products
    • Manufacturer Reports
    • HVAC Data
    • Legislation
    • ACHR NEWS Centennial
  • RESIDENTIAL
    • Air Conditioners
    • Furnaces
    • Residential Heat Pumps
    • Ductless
    • Residential IAQ
    • Testing, Monitoring, Tools
    • Components & Accessories
  • COMMERCIAL
    • Air Handlers
    • Rooftop Units
    • Chillers and Cooling Towers
    • Commercial Heat Pumps
    • Boilers and Hydronics
    • VRF/Ductless
    • Commercial IAQ
  • REFRIGERATION
    • Refrigerants
    • Refrigerant Regulations
    • Leak Management
  • CONTRACTOR PRO
    • Geothermal
    • Homeowner Study
    • VRF and VRV Ductless
    • Unitary Trends
  • EDUCATION
    • Training and Education
    • Business Management
    • Service and Maintenance
    • Continuing Education
    • Market Research >
      • HVAC Brand Awareness Report
      • VRV, VRF, VRVZ Report
      • Unitary Trends Report
      • Water Heat Professionals Report
    • Webinars
    • Sponsor Insights
    • eProducts Info
    • White Papers
  • EVENTS
    • HVAC Contractor Forum
    • Industry Events and Webinars
  • MEDIA
    • Videos
    • AHR Expo 2025 Videos
    • Podcasts >
      • ACHR News Podcast
      • HARDI Podcasts
      • AHR Expo Podcasts
      • ACCA Podcasts
    • Interactive Spotlights
    • Quizzes
    • eBooks
    • HVAC Talkback
  • HVAC GROUP
    • ACHR NEWS >
      • Current Issue
      • Digital Edition
      • Subscribe
    • Distribution Trends
    • SNIPS NEWS >
      • Join SNIPS NEWS
    • Engineered Systems News >
      • Join ES News
    • HVACR Directory
    • Contests
    • Newsletters
    • Contact
    • Advertise
    • My Account
HVAC ContractingTechnical

Saving Money With Best Practices and an Energy Inspection Checklist

By Ron Auvil
March 8, 2010
To spot missing insulation, use a fairly sensitive thermal imager with blended digital/thermal view. That’s because a) differences in temperature indicating a gap can be relatively small and b) while a gap may read clearly in infrared, finding the spot on the wall afterwards is difficult if you don’t have digital landmarks within the thermal view to go by. (Click on the image for an enlarged view.)

With the economic downturn, many facility managers are facing very tight operation and maintenance budgets. Luckily, many facilities are sitting on multiple energy conservation opportunities that can save thousands of dollars per year with relatively little capital investment.

If capital expenditures at your customers’ facilities for new HVAC mechanical equipment have been frozen or eliminated, one way to free up financial resources is to tune up existing HVAC equipment. Follow best maintenance practices and the increased operating efficiency will reduce energy consumption. Cumulative energy bill savings can then supplement the general budget.

While HVAC systems vary widely in terms of equipment and operational characteristics, the following checklist should generally apply to most main equipment types and energy waste areas:

Steam system checklist:
• Insulation checks: Loose or missing insulation costs thousands of dollars in extra fuel costs per heating season. Use a thermal imager to inspect system insulation and identify insufficient areas.

If you don’t see a distinct temperature difference on either side of a steam trap, it may be failed and needs to be further investigated.

• Steam trap checks: Steam traps remove condensate from heating and process equipment. If the traps fail open, valuable steam is lost. To spot a failed trap, use a non-contact thermal imager, infrared thermometer, or a contact thermometer to compare the temperature of the trap to the pipe on either side of it. Thermography and infrared thermometers hold obvious advantages for traps mounted in awkward areas. Normal temperature differences across steam traps are approximately 20°F.

• Check air temperatures in boiler room: Proper combustion requires that the combustion air be between proper limits. Use a digital thermometer designed to measure ambient air temperatures and consider checking the carbon monoxide level in the boiler room, as well, to ensure safety.

• Other: In addition to the steps made above, also check the feedwater temperature, fuel oil heater temperature, and other items such as lubricant. These checks may not only save energy but also costs due to equipment repair or failure.

When taking readings near any combustion equipment, measure not only CO but CO2 and temperature as well.

Cooling system checklist:
• Electrical checks: Check compressor voltage and amperage to ensure that the motor is operating at manufacturer-recommended levels.

• Temperature checks: Check the temperatures of inlet and outlet air and water temperatures at heat exchangers to verify they are operating at their most efficient levels. Chilled water supply temperatures for most chilled water systems should be between 42° and 44°.

• Pressure checks: Use a digital multimeter with a pressure attachment to take the inlet and outlet pressures of shell and tube heat exchangers, to ensure the tubes are not fouled. Fouling will result in lower heat transfer and higher energy consumption at the compressor. Pressure drop across the heat exchanger (Delta P) may be anywhere from 5 psig to 25 psig and varies by manufacturer. Check refrigerant and pump pressures, as well, to ensure equipment is operating at baseline levels.

• Cooling tower checks: For cooling equipment to operate at its most efficient levels, the cooling tower must operate properly. Since cooling towers reject heat at a specific rate to the atmosphere, use a temperature/humidity meter to measure the outside air temperature and humidity and analyze cooling tower operation. Also measure the temperature of the condensing water supplied to the chiller. A common value is 85°.

Some electrical test tools, such as this Fluke 902 Clamp Meter, offer temperature measurement too, making it easier to build in temperature checks.

Fan system checklist:
• Electrical checks: Measure the voltage and amperage of the fan motor and compare to nameplate conditions.

• Temperature checks: Check the following values at air handlers:

- Outside air temperature

- Mixed air temperature

- Return air temperature

- Discharge or supply air temperature

- Coil face discharge air temperatures

- Space temperature sensors

- Economizer and related dampers

- Wet bulb temperature or relative humidity (rh) sensors

Take readings with a handheld temperature meter and compare them against those indicated by the control system to ensure accuracy. Sensor calibration should be an integral part of all maintenance programs.

• Air pressure checks: Check pressure drops across filter banks to ensure adequate airflow. Excessive pressure drops will cause higher than normal energy consumption. Measure air pressure drops across heating and cooling coils to ensure that the coils are clean. Measure the inlet and outlet air temperatures to ensure proper temperature rise or drop.

Lighting system checklist:
• Electrical checks: Thermography applications for lighting include ballast and breaker contact temperatures. Look for hotspots and compare values with baselines or previous temperature measurements for evaluation.

• Illumination levels: Use a light meter to measure foot-candle or lumen levels. Where possible, reduce illumination levels to industry standards. Especially consider reducing illumination during seasons when more natural light is available.

• Operational checks: Set up a recording meter to sample illumination levels during a facility’s unoccupied hours. This will help identify areas where the lights are left on inadvertently or unnecessarily.

Hook a power quality monitor up to specific circuits and equipment, such as chillers, to determine energy consumption.

Building automation system checklist:
• Energy consumption checks: Use a power quality meter to evaluate your facility’s voltage, current, and kWh energy consumption. If possible, log energy consumption over time on specific circuits, and by specific equipment and areas. Compare your hourly usage rate to your utility fee structure and adjust usage patterns out of high-demand, high-cost times of day. Also check control system supply voltages to ensure proper controller operation. Controller communication bus values may be checked to ensure the integrity of the communication wiring.

• Control system: Check all sensors and indicating thermometers for properly calibrated gauges. Check valve and damper actuators as well. Actuator problems can cause higher than normal heating and cooling usage and high energy bills. Actuator output voltages and current signals can be checked using a regular digital multimeter.

• Temperature checks: Check the temperatures of inlet and outlet air and water temperatures at heat exchangers to make sure that they are operating at their most efficient levels. For example, chilled water supply temperatures for most chilled water systems are between 42° and 44°.

• Operational checks: Log air temperature over time, over occupied and unoccupied schedules, to identify areas left in the wrong temperature mode at night or on weekends, wasting energy.

• Setpoint checks: Check the accuracy of all temperature, pressure, and humidity control setpoints by logging those values over time. Control inaccuracy may waste 1 percent of energy per degree of error.

Reprinted with permission from the Fluke Application Note “Save Money With Best Practices and an Energy Inspection Checklist.” For more information, visit www.fluke.com.

Publication date: 03/08/2010

Share This Story

Looking for a reprint of this article?
From high-res PDFs to custom plaques, order your copy today!

 

Ron Auvil is a senior instructional consultant for a major HVAC/controls manufacturer, specializing in staff and workforce performance issues. He is a leading voice in today’s movement toward operational excellence. An author and curriculum developer, he has worked with some of the world’s largest and most quality-conscious companies, providing custom training on how to improve the operations of their environmental systems. His clients have included NASA, the Pentagon, the University of South Carolina, and others. Ron.Auvil@jci.com

Recommended Content

JOIN TODAY
To unlock your recommendations.

Already have an account? Sign In

  • HVAC-enrollment

    The Trades Are Back: HVACR Programs See Nearly 30% Enrollment Spike

    A new wave of future technicians is entering the pipeline.  
    Training and Education
    By: Matt Jachman
  • 2025 Top 40 Under 40

    2025 Top 40 Under 40 HVACR Professionals List

    The 11th annual Top 40 Under 40 list highlights those...
    News
    By: Hannah Belloli-Oster
  • LG Ductless Mini-Split Systems

    The 9 Types of Heat Pumps

    As the U.S. moves toward electrification, heat pumps are...
    HVAC Residential Market
    By: Joanna R. Turpin
Subscription Center
  • Create an Account
  • Start a Subscription
  • Manage My Account
  • Sign Up for Newsletters
  • Visit Customer Service
  • Update Preferences

More Videos

Sponsored Content

Sponsored Content is a special paid section where industry companies provide high quality, objective, non-commercial content around topics of interest to The News audience. All Sponsored Content is supplied by the advertising company and any opinions expressed in this article are those of the author and not necessarily reflect the views of The News or its parent company, BNP Media. Interested in participating in our Sponsored Content section? Contact your local rep!

close
  • Piggy Bank
    Sponsored byWatercress Financial

    Energy Prices, Inflation, and HVAC: What Today’s Homeowners Care About

  • Refrigerated Food
    Sponsored bySolstice Advanced Materials

    R-455A Refrigeration: A Cold Storage Solution for the Future

  • Airex Rooftop Units
    Sponsored byAirex Manufacturing Inc

    Consolidating Roof Penetrations: A Growing Trend in Multifamily HVAC Design

Popular Stories

HVAC-Price-Increase-graphic

HVAC Price Increase List: June 2026

Trump-Section-232.jpg

Trump Reduces Section 232 Tariffs on HVAC Equipment to 15%

R410A-Refrigerant-Cylinder.jpg

Refrigerant Recovery is a Revenue Opportunity

Heat-pump-cutaway.jpg

PFAS Rules and A2L Building Codes Continue to Evolve

Kroger.jpg

Kroger to Spend $100 Million to Reduce Refrigerant Leaks

View The ACHR NEWS
Centennial Anniversary Timeline

The ACHR News Timeline Chart
Submit a Letter
Submit a letter to our editors.

Events

November 6, 2025

Next-Gen Data Center Cooling: HVAC Innovation and Real-World Solutions

On Demand As AI workloads and high-density computing push traditional cooling methods to their limits, the data center industry is accelerating the adoption of next-generation HVAC technologies.

June 17, 2026

Decarbonization Without Disruption

This webinar will explore practical HVAC decarbonization strategies that minimize disruption while maximizing long-term performance and ROI.

View All Submit An Event

Poll

Summer Staff

Are you fully staffed for the summer season?
View Results Poll Archive

Products

BNI Mechanical/Electrical Square Foot Costbook, 2026 Edition

BNI Mechanical/Electrical Square Foot Costbook, 2026 Edition

See More Products
A2L Refrigerants - Free Webinar - May 21, 2026

Related Articles

  • MCAA Honors NY Affiliate With Best Practices Award

    See More
  • 70% of Households with Smart Energy Devices Report Saving Money

    See More
  • June 5, 2006: Energy Star Offers Tips for Saving Money While Staying Cool

    See More

Related Products

See More Products
  • The ACHR News - May 18, 2026

    ACHR NEWS May 18, 2026, Issue

  • 1987.gif

    HVAC Duct Systems Inspection Guide

  • SMACNA-logo8.gif

    Architectural Sheet Metal Inspection Guide

See More Products

Related Directories

  • Energy Saving Products Inc.

    Distributors of Infrared Heaters and HVLS Fans.
×

Sign Up. Stay Informed.

The #1 trusted source for the HVACR industry since 1926

SUBSCRIBE
  • RESOURCES
    • Advertise
    • Contact Us
    • Advisory Board
    • Classifieds
    • Submit a Letter
    • Directories
    • Store
  • ACCOUNT CENTER
    • Create an Account
    • Start a Subscription
    • Manage My Account
    • Sign Up for Newsletters
    • Visit Customer Service
    • Update Preferences
  • SERVICES
    • Marketing Services
    • Reprints
    • Market Research
    • List Rental
    • Survey/Respondent Access
  • STAY CONNECTED
    • LinkedIn
    • Facebook
    • Instagram
    • YouTube
    • X (Twitter)
  • PRIVACY
    • PRIVACY POLICY
    • TERMS & CONDITIONS
    • DO NOT SELL MY PERSONAL INFORMATION
    • PRIVACY REQUEST
    • ACCESSIBILITY

Copyright ©2026. All Rights Reserved BNP Media, Inc. and BNP Media II, LLC.

Design, CMS, Hosting & Web Development :: ePublishing