ACHR News
search
Ask ACHR NEWS AI
cart
facebook twitter instagram linkedin youtube
  • Sign In
  • Subscribe
  • Sign Out
  • My Account
ACHR News
  • NEWS
    • Breaking News
    • New HVAC Products
    • Featured Products
    • Manufacturer Reports
    • HVAC Data
    • Legislation
    • ACHR NEWS Centennial
  • RESIDENTIAL
    • Air Conditioners
    • Furnaces
    • Residential Heat Pumps
    • Ductless
    • Residential IAQ
    • Testing, Monitoring, Tools
    • Components & Accessories
  • COMMERCIAL
    • Air Handlers
    • Rooftop Units
    • Chillers and Cooling Towers
    • Commercial Heat Pumps
    • Boilers and Hydronics
    • VRF/Ductless
    • Commercial IAQ
  • REFRIGERATION
    • Refrigerants
    • Refrigerant Regulations
    • Leak Management
  • CONTRACTOR PRO
    • Geothermal
    • Homeowner Study
    • VRF and VRV Ductless
    • Unitary Trends
  • EDUCATION
    • Training and Education
    • Business Management
    • Service and Maintenance
    • Continuing Education
    • Market Research >
      • HVAC Brand Awareness Report
      • VRV, VRF, VRVZ Report
      • Unitary Trends Report
      • Water Heat Professionals Report
    • Webinars
    • Sponsor Insights
    • eProducts Info
    • White Papers
  • EVENTS
    • HVAC Contractor Forum
    • Industry Events and Webinars
  • MEDIA
    • Videos
    • AHR Expo 2025 Videos
    • Podcasts >
      • ACHR News Podcast
      • HARDI Podcasts
      • AHR Expo Podcasts
      • ACCA Podcasts
    • Interactive Spotlights
    • Quizzes
    • eBooks
    • HVAC Talkback
  • HVAC GROUP
    • ACHR NEWS >
      • Current Issue
      • Digital Edition
      • Subscribe
    • Distribution Trends
    • SNIPS NEWS >
      • Join SNIPS NEWS
    • Engineered Systems News >
      • Join ES News
    • HVACR Directory
    • Contests
    • Newsletters
    • Contact
    • Advertise
    • My Account
HVAC ContractingService and Maintenance

Gas Furnace Maintenance

March 4, 2005
The following are recommended gas furnace maintenance procedures. The furnace owner should be urged to have a professional service contractor check the performance and operation of the furnace every year. This ensures the furnace owner of receiving the best possible performance and comfort from the equipment.

Warning: Disconnect the main electrical power to the unit before attempting any maintenance. Failure to turn off the electrical power may result in shock, causing personal injury or death.

Note that a new home may require more frequent filter attention until the dust from construction is removed.

Filters

1. Keep the air filters clean. A new home may require more frequent filter attention until dust from construction is removed.

2. How to clean filters:

Plastic filters - Vacuum clean; wash with detergent and water. Air dry thoroughly and reinstall.

Cardboard and fiberglass - Discard when dirty and replace with a like-sized similar filter.

3. If using an electronic air filter, remove the filter furnished with the furnace and follow the maintenance instructions furnished with the electronic air filter.

Important: Do not operate the furnace without filters. Dust entrained with the air can lodge in the blower wheel, in the cooling coil fins, in furnace controls, in air ducts, and at the supply registers. Any recirculated dust particles are heated and charred by contact with the heat exchanger. This residue soils ceilings, walls, drapes, carpets, and other household articles.

Important: If replacing the factory filter with an aftermarket filter, always check the furnace temperature rise to be sure the airflow is adequate.

Looking for quick answers on air conditioning, heating and refrigeration topics? Try Ask ACHR NEWS, our new smart AI search tool. Ask ACHR NEWS →

Note: Some filters must be resized to fit certain units and applications.

For example, some units require removal of a segment of filter and frame for proper width for a bottom or side filter.



Lubrication

The indoor blower motor sleeve bearings and induced draft motor are prelubricated and should not require attention for an indefinite period of time. However, these are some recommendations for service technicians:

1. Motors without oiling ports - prelubricated and sealed. No further lubrication is required. In case of bearing problems, the service technician should replace the motor.

2. Motors with oiling ports – add 10 to 20 drops of electric motor oil to each bearing every two years for somewhat continuous duty, or at least every five years for light duty. Do not over-oil.

Excessive lubrication can damage the motor.

3. To access oiling ports or to relubricate sealed indoor blower motor bearing, remove the blower assembly and motor.

A. Remove the wiring from the control board compartment.

B. Remove the screws from the blower housing that secure the assembly.

C. Slide the blower assembly out.

D. Loosen the set screw(s) securing the blower wheel to the motor shaft, remove any motor ground wire, and remove the screws from the motor mounting bracket legs.

E. Slide the bracket assembly from the housing.

F. Lubricate the motor bearings.

G. Reassemble using the reverse procedure outlined above.

Exercise care when sliding the blower assembly back into the unit and be sure that it is reinstalled properly.

The service technician should clean the motor periodically to prevent the possibility of overheating due to an accumulation of dust or dirt on the windings and the motor exterior. If the motor needs cleaning, clean the blower wheel also. A blower wheel loaded with dirt or dust limits airflow, eventually causing furnace damage.

As suggested earlier, clean or replace the air filters. Dirty filters restrict airflow and adversely affect blower and furnace operation.

Burner And Heating Components

The furnace should operate for many years with no malfunctions. However, the service technician should inspect the heat exchanger passages, the venting system, and the burners for correct operation, and for any signs of corrosion. The heat exchanger passages and vent system should be inspected (and cleaned if required) by the technician annually.

It is recommended that the heat exchanger be removed for inspection. However, with some products, this may not be feasible. If the heat exchanger is removed, the technician should follow these procedures.

1. Turn off furnace electrical power and set the thermostat to its lowest temperature.

2. Shut off the gas supply to the furnace either at the meter or at a manual valve in the supply piping.

3. Remove the burner door. On downflow and dedicated horizontal models, the blower door and burner door flange must also be removed.

4. Disconnect the gas supply piping from the gas valve.

5. Remove screws connecting the burner tray to the center panel.

6. Mark all wires on the gas valve for proper reconnection and disconnect the gas valve wiring.

7. Remove the burner tray and manifold assembly from the unit.

8. Remove all screws in the unit top plate. Remove the wires and tube from the pressure switch. Remove the top plate with the pressure switch attached.

9. Remove the draft inducer wiring. Remove screws connecting the draft inducer to the center panel. Take care not to damage the gasket behind the draft inducer.

10. Remove screws on heat exchanger perimeter. With hot surface ignition, remove the connecting screws along with the associated wiring.

11. With an upward and forward motion, lift the heat exchanger from the unit.

12. Clean or replace the heat exchanger, if necessary, and reinstall.

13. Reassemble the furnace in reverse order.

Warning: Holes in the vent piping or heat exchanger can allow toxic fumes to enter the home. Replace the vent pipe or heat exchanger if leaks are found. Failure to follow this warning may cause products of combustion to circulate into the living space creating potentially hazardous conditions, including carbon monoxide poisoning.

It is recommended that at the beginning of the heating season and about midway through the heating season the service technician visually inspect the main burners and pilot burner for proper flame characteristics.

Any furnace using existing high-temperature plastic vent piping must have the vent inspected annually for any cracks, pipe separation, or other deterioration of the vent material.

Important: At the beginning of the heating season, the flame sensor on electronic ignition units should be cleaned with steel wool by the technician.

Reprinted with permission from the 80% Low Profile Single Stage Gas Furnace service manual from Rheem Air Conditioning Division, Fort Smith, Ark. For more information, visit www.rheemac.com.

Publication date: 03/07/2005

Share This Story

Looking for a reprint of this article?
From high-res PDFs to custom plaques, order your copy today!

 

Recommended Content

JOIN TODAY
To unlock your recommendations.

Already have an account? Sign In

  • HVAC-enrollment

    The Trades Are Back: HVACR Programs See Nearly 30% Enrollment Spike

    A new wave of future technicians is entering the pipeline.  
    News
    By: Matt Jachman
  • 2025 Top 40 Under 40

    2025 Top 40 Under 40 HVACR Professionals List

    The 11th annual Top 40 Under 40 list highlights those...
    HVAC Light Commercial Market
    By: Hannah Belloli-Oster
  • LG Ductless Mini-Split Systems

    The 9 Types of Heat Pumps

    As the U.S. moves toward electrification, heat pumps are...
    Air Source Heat Pumps
    By: Joanna R. Turpin
Subscription Center
  • Create an Account
  • Start a Subscription
  • Manage My Account
  • Sign Up for Newsletters
  • Visit Customer Service
  • Update Preferences

More Videos

Sponsored Content

Sponsored Content is a special paid section where industry companies provide high quality, objective, non-commercial content around topics of interest to The News audience. All Sponsored Content is supplied by the advertising company and any opinions expressed in this article are those of the author and not necessarily reflect the views of The News or its parent company, BNP Media. Interested in participating in our Sponsored Content section? Contact your local rep!

close
  • Piggy Bank
    Sponsored byWatercress Financial

    Energy Prices, Inflation, and HVAC: What Today’s Homeowners Care About

  • Refrigerated Food
    Sponsored bySolstice Advanced Materials

    R-455A Refrigeration: A Cold Storage Solution for the Future

  • Airex Rooftop Units
    Sponsored byAirex Manufacturing Inc

    Consolidating Roof Penetrations: A Growing Trend in Multifamily HVAC Design

Popular Stories

HVAC-Price-Increase-graphic

HVAC Price Increase List: June 2026

Trump-Section-232.jpg

Trump Reduces Section 232 Tariffs on HVAC Equipment to 15%

R410A-Refrigerant-Cylinder.jpg

Refrigerant Recovery is a Revenue Opportunity

Heat-pump-cutaway.jpg

PFAS Rules and A2L Building Codes Continue to Evolve

Kroger.jpg

Kroger to Spend $100 Million to Reduce Refrigerant Leaks

View The ACHR NEWS
Centennial Anniversary Timeline

The ACHR News Timeline Chart
Submit a Letter
Submit a letter to our editors.

Events

November 6, 2025

Next-Gen Data Center Cooling: HVAC Innovation and Real-World Solutions

On Demand As AI workloads and high-density computing push traditional cooling methods to their limits, the data center industry is accelerating the adoption of next-generation HVAC technologies.

June 9, 2026

Before You Go All In on AI: Set Up Your Business to Actually Win

In this webinar, we'll walk you through exactly what to get in place before you add AI to your business. You'll leave with a clear picture of where you stand today and a practical action plan to set yourself up for real results.

View All Submit An Event

Poll

Summer Staff

Are you fully staffed for the summer season?
View Results Poll Archive

Products

BNI Mechanical/Electrical Square Foot Costbook, 2026 Edition

BNI Mechanical/Electrical Square Foot Costbook, 2026 Edition

See More Products
A2L Refrigerants - Free Webinar - May 21, 2026

Related Articles

  • Basic Furnace Maintenance and Troubleshooting

    Basic Furnace Maintenance and Troubleshooting

    See More
  • Furnace Maintenance Heats Up

    See More
  • Furnace Maintenance in High Gear

    See More

Related Products

See More Products
  • Green Tips for Building Maintenance Engineers

  • Tech_CommRef_Guide_Small.jpg

    Technician’s Guide & Workbook for Quality Maintenance on Commercial Refrigeration Equipment

  • HVAC and Refrigeration Preventive Maintenance.jpeg

    HVAC and Refrigeration Preventive Maintenance

See More Products

Events

View AllSubmit An Event
  • September 9, 2025

    How Maintenance Plays into the HVAC Decarbonization Trend

    On Demand This webinar will explore maintenance strategies for advanced HVAC systems, including VAVs and demand-controlled ventilation.
View AllSubmit An Event

Related Directories

  • Dornback Furnace Div.

    Residential and light commercial gas, and oil-fired warm air furnaces, barometric draft controls, electronic air cleaners, humidifiers, unit heaters, infrared heaters and gas and oil burners and waste oil heaters.
×

Sign Up. Stay Informed.

The #1 trusted source for the HVACR industry since 1926

SUBSCRIBE
  • RESOURCES
    • Advertise
    • Contact Us
    • Advisory Board
    • Classifieds
    • Submit a Letter
    • Directories
    • Store
  • ACCOUNT CENTER
    • Create an Account
    • Start a Subscription
    • Manage My Account
    • Sign Up for Newsletters
    • Visit Customer Service
    • Update Preferences
  • SERVICES
    • Marketing Services
    • Reprints
    • Market Research
    • List Rental
    • Survey/Respondent Access
  • STAY CONNECTED
    • LinkedIn
    • Facebook
    • Instagram
    • YouTube
    • X (Twitter)
  • PRIVACY
    • PRIVACY POLICY
    • TERMS & CONDITIONS
    • DO NOT SELL MY PERSONAL INFORMATION
    • PRIVACY REQUEST
    • ACCESSIBILITY

Copyright ©2026. All Rights Reserved BNP Media, Inc. and BNP Media II, LLC.

Design, CMS, Hosting & Web Development :: ePublishing