search
Ask ACHR NEWS AI
cart
facebook twitter instagram linkedin youtube
  • Sign In
  • Subscribe
  • Sign Out
  • My Account
  • NEWS
  • TECHNOLOGY
    • Heating & Boilers
    • Cooling & Chillers
    • Pumps & Flow Controls
  • SECTORS
    • Commercial
    • Health Care
    • Data Center
    • Educational Facilities
  • DESIGN | CONSTRUCTION
  • OTHER TOPICS
    • High-Performance Buildings & Automation
    • Ventilation and IAQ
    • Commissioning
    • HVAC Retrofits
  • TODAY’S BOILER
    • Today’s Boiler Archives
    • Today’s Boiler Digital Edition
  • MORE
    • Case Studies
    • Podcasts
    • Videos
    • Directory
    • Webinars
    • ES NEWS Store
    • White Papers
  • SIGN UP
  • Back to The NEWS
Engineered Systems NEWSHVAC Engineering SectorsHVAC Design/Construction ProcessHigh-Performance Buildings & AutomationCommercial HVAC

Retrofitting A BAS: The Devil's In The Details

Replacing it all isn’t always needed or in the budget. Apply some guidelines to evaluating these field devices.

By Ira Goldschmidt P.E.
Ira Goldschmidt, P.E.
September 6, 2017

Older BAS are typically replaced when BAS controllers and/or operator interface (the “brains”) are at the end of their useful life. This typically means that the brains are no longer supported by the manufacturer. BAS are custom-built, using many components besides the “brains.” These include actuators/valves, sensors/switches, various types of wiring, conduit/EMT/J-boxes, enclosures including power supplies/transformers, etc. For the sake of this subject, I will refer to these components as field devices. How much of the system beyond the brains should also be replaced?

The simplest approach to designing a BAS retrofit is, of course, to specify that everything be replaced. However, this may not provide the best value to the owner. The cost of field devices represents a substantial portion of a BAS installation, yet they are neither part of the system’s brains nor do they all share the same expected length of useful life. Instead, field devices need to be evaluated to determine the optimum combination of replace vs. reuse … the devil is in the details. The following are suggestions about how to negotiate these details without the need for excessive design efforts.

 

How Do You Judge the Useful Life of Field devices?


“Replace pneumatic actuators where possible, regardless of the age (the electric-to-pneumatic transducer and often-needed pilot positioner adds complexity and reduces reliability, and they don’t easily allow for position feedback). Electronic valves should be observed for smooth end-to-end operation.”


There is no easy answer to this question. I usually start with 20 years and then look at various other factors to decide if it should be more or less. These factors include the physical condition, the owner’s experience with the reliability of the device, whether it is readily compatible with a modern BAS, and any experience I may have had with the device’s accuracy/dependability.

 

Field Device Compatibility With a New BAS?

Most field devices will work with any brand or generation of BAS. The obvious examples include conduit/EMT/J-boxes and power supplies/transformers. Point wiring can also be a safe bet if it is 18ga. UTP but not communications wiring (especially if the retrofit involves a change in the communications protocol). Most sensors/switches/relays are also compatible unless something one-off was used.

If in doubt, contact a couple of BAS contractors that you trust and discuss your device compatibility concerns or just specify that they be replaced.

 

Additional Advice For Some Specific Field Devices

  1. Actuators/valves – Replace pneumatic actuators where possible, regardless of the age (the electric-to-pneumatic transducer and often-needed pilot positioner adds complexity and reduces reliability, and they don’t easily allow for position feedback). Electronic valves should be observed for smooth end-to-end operation. Valves (especially those with integral actuators) can have a greatly shortened life — observing their operation via the BAS (i.e., to see if they open and close fully) helps greatly.

  2. Temperature sensors – Thermistors or 1KΩ RTD’s are most commonly used. Their point signaling is via a varying resistance, and there are many different types of sensors each with a different resistance curve. Some BAS can be readily programmed with any sensor’s resistance curve, while others not so much. Again, follow the above “if in doubt” advice.

  3. Conduit/EMT/J-boxes – Generally, I see no reason not to allow the re-use of these regardless of age unless they look in bad shape.

  4. Enclosures – Regardless of the condition of an enclosure, I’ve seen bad results when they are reused. The reason is that they will be rebuilt in the field (using as much of the existing innards as possible), which typically leads to shoddy results. New shop-built enclosures are probably best.

 

Final Word

Regardless of the above, there’s no reason for the specification to require the contractor to re-use anything if they are concerned that it might be a weak link in their system. Just say “may be re-used” and leave it up to the contractor to make the final decision.

Share This Story

Looking for a reprint of this article?
From high-res PDFs to custom plaques, order your copy today!

 

Iragold

Ira has worked in the building industry for over 35 years as a controls tech, MEP designer, and consultant providing design/guidance for critical-facility BAS and intelligent building systems integration. He is a co-author of the ASHRAE BACnet® standard and Guideline 13 — Specifying DDC Controls.

WWW.ESMAGAZINE.COM/IRA
Use this handy shortcut to see Ira’s collected BAS wisdom in ES columns and other articles.

Recommended Content

JOIN TODAY
To unlock your recommendations.

Already have an account? Sign In

  • HVAC-enrollment

    The Trades Are Back: HVACR Programs See Nearly 30% Enrollment Spike

    A new wave of future technicians is entering the pipeline.  
    Training and Education
    By: Matt Jachman
  • 2025 Top 40 Under 40

    2025 Top 40 Under 40 HVACR Professionals List

    The 11th annual Top 40 Under 40 list highlights those...
    HVAC Light Commercial Market
    By: Hannah Belloli-Oster
  • LG Ductless Mini-Split Systems

    The 9 Types of Heat Pumps

    As the U.S. moves toward electrification, heat pumps are...
    HVAC Commercial Market
    By: Joanna R. Turpin

More Videos

Today's Boiler

Spring 2026 Issue

Today's Boiler - Spring 2026 Cover

Read More from Today's Boiler

Case in Point Logo

Smarter Hydronic Design for Data Centers - Free Webinar - January 22, 2026

Related Articles

  • The Devil in the Details

    See More
  • The Proof is in the Details

    See More
  • Ira Goldschmidt, P.E.

    Should You Sole-Source A BAS?

    See More

Related Products

See More Products
  • air came to a stop.jpg

    The Air Came to a Stop

  • Lessons Learned in a Boiler Room: A common sense approach to servicing and installing commercial boilers

See More Products

Related Directories

  • The Master Group

    The Master Group is the largest independently owned HVAC-R distributor in Canada, with over 50 branches and 4 distribution centers. Visit www.master.ca for details.
  • The Malco Group

    The Malco Group is a leading manufacturer and distributor of high-quality HVACR solutions that power the success of businesses, trade pros end-users, and homes across North America.
×

Sign Up. Stay Informed.

The #1 trusted source for the HVACR industry since 1926

SUBSCRIBE
  • RESOURCES
    • Advertise
    • Contact Us
    • Advisory Board
    • Classifieds
    • Submit a Letter
    • Directories
    • Store
  • ACCOUNT CENTER
    • Create an Account
    • Start a Subscription
    • Manage My Account
    • Sign Up for Newsletters
    • Visit Customer Service
    • Update Preferences
  • SERVICES
    • Marketing Services
    • Reprints
    • Market Research
    • List Rental
    • Survey/Respondent Access
  • STAY CONNECTED
    • LinkedIn
    • Facebook
    • Instagram
    • YouTube
    • X (Twitter)
  • PRIVACY
    • PRIVACY POLICY
    • TERMS & CONDITIONS
    • DO NOT SELL MY PERSONAL INFORMATION
    • PRIVACY REQUEST
    • ACCESSIBILITY

Copyright ©2026. All Rights Reserved BNP Media, Inc. and BNP Media II, LLC.

Design, CMS, Hosting & Web Development :: ePublishing