Engineered Systems NEWSCase in Point

Hotel succeeds with waterfront views, upfront BAS needs

June 1, 2010
The Hilton San Diego Bayfront has an integrated controls system that allows for programming of the AHU and central plant and for demand control and energy efficiency sequences.


Rising 30 stories above San Diego Bay, the Hilton San Diego Bayfront hotel opened in 2008 as California’s newest waterfront skyscraper hotel. The property, with its spectacular terrace over the Bay and its sun-drenched interiors, exemplifies the best of post-modern architecture and state-of-the-art engineering technologies.

Just minutes from the airport, adjacent to the San Diego Convention center, the hotel has 1,190 guest rooms, 30 luxury suites, and 165,000 sq ft of meeting space. It is one of the most comfortable hotel environments on the West Coast, due in part to its innovative HVAC and BAS.

Right from the planning stage, the developer placed top priority on energy efficiency coupled with guest comfort. Moreover, the hotel had to be built for long-term sustainability with technologies that could be easily and cost effectively be upgraded as needed.

HIGH ON THE LIST OF PRIORITIES

Since the Hilton San Diego Bayfront project was green field construction, the BAS had to meet very stringent and specific criteria. Distech Controls’ systems integrator, Dynalectric San Diego, supplied a complete spectrum of BAS services based on the developer’s priorities. Distech Controls was selected on the basis of and open system based on LonWorks® technology; continuous source of system components, which meant original hardware and software from the manufacturer had to be consistently available and later versions had to be compatible; and easy integration and future enhancements capability.

The BAS had to allow for the seamless integration of additional components. Furthermore, the system had to provide the ability to easily leverage future technology improvements.

ENGINEERING AN OPTIMAL BAS

The hotel’s central mechanical system is ultramodern and highly efficient. There is a chilled water system (CHW) consisting of three 85- ton chillers, three CHW pumps, and three secondary CHW pumps. Distech Controls’ EC-Net solution uses Btu metering to ensure that the chillers are staged in order to meet building cooling load demand. This maintains energy consumption at the lowest level possible.

The condenser water (CW) system has three cooling towers on a constant volume loop with three CW pumps. Two steam boilers are dedicated to laundry operations. The primary and secondary hot water systems (HWS) consist of two boilers, two primary HWS pumps, two secondary HWS pumps, and two heat exchangers. Distech Controls’ EC-Net solution uses Btu metering for the HWS system.

For optimal guest comfort, the heat exchangers isolate the heating on different guest room floors. In addition, the temperature in the pool/spa area is regulated by two heat exchangers and control valves in the primary and secondary loops. The hotel’s airside mechanical system includes a number of components including 264 VAV boxes plus 54 fancoil units and two constant volume AHUs, and four package A/C units. There are 24 VAV AHUs providing mixed air with CHW cooling and HWS heating.

To reduce the amount of energy consumed by the building, the AHUs are set for static pressure supply fan control with an economizer, demand control ventilation, and discharge temperature reset based on average zone temperature.

The meeting spaces and ballrooms are optimized for energy consumption and occupant comfort, with demand controlled ventilation utilizing CO2 monitoring and control. In each of the 52 electrical equipment rooms, there is a dedicated fancoil unit providing temperature control via constant volume fan and chilled water coil. The main telephone and data room has four heat pump A/C units for critical load application to meet the stringent temperature regulation demands.

AN INTEGRATED CONTROLS SYSTEM

Distech Controls supplied a range of products for the hotel project, starting with 322 LonWorks configurable terminal unit controllers and 35 programmable controllers, allowing for custom programming of the large AHU and central plant control as well as demand control ventilation and energy efficiency sequences. Distech Controls’ EC-Light, LonWorks lighting solution, was used for exterior lighting control. Mechanical and electrical equipment connected to the LonWorks controllers was integrated via EC-Net, Distech Controls’ Web-based network management and graphical user interface.

CUSTOMER BENEFITS

Thanks to Dynalectric’s engineering expertise and the time-saving features of Distech Controls’ products, the developer saved 20% in installation and commissioning costs.

The building operators can quickly access all aspects of the system from a Web browser, allowing for prompt response to all facility needs. The user-friendly interface of the EC-Net system significantly improves the performance of day-to-day operation.

Today, the Hilton San Diego Bayfront operates at an extremely high level of energy efficiency. Down the road, the hotel has the ability to easily expand or enhance any part of its BAS as needs arise. By clearly establishing system performance standards, the customer was able to obtain a truly sustainable BAS that serves its needs now and into the future. ES

Share This Story

Looking for a reprint of this article?
From high-res PDFs to custom plaques, order your copy today!

 

Recommended Content

JOIN TODAY
To unlock your recommendations.

Already have an account? Sign In

  • HVAC-enrollment

    The Trades Are Back: HVACR Programs See Nearly 30% Enrollment Spike

    A new wave of future technicians is entering the pipeline.  
    News
    By: Matt Jachman
  • 2025 Top 40 Under 40

    2025 Top 40 Under 40 HVACR Professionals List

    The 11th annual Top 40 Under 40 list highlights those...
    HVAC Light Commercial Market
    By: Hannah Belloli-Oster
  • LG Ductless Mini-Split Systems

    The 9 Types of Heat Pumps

    As the U.S. moves toward electrification, heat pumps are...
    Air Source Heat Pumps
    By: Joanna R. Turpin

More Videos

Today's Boiler

Spring 2026 Issue

Today's Boiler - Spring 2026 Cover

Read More from Today's Boiler

Case in Point Logo

Smarter Hydronic Design for Data Centers - Free Webinar - January 22, 2026

Related Articles

  • Comfort, Efficiency Check In Following Brazil Hotel's Bas Integration

    See More
  • ProSys Fill

    Why Upfront Savings Can Lead to Long-Term Losses with Filling Equipment

    See More
  • Boston Hotel Stays Neighborly With Kitchen Emission Controls

    See More

Related Products

See More Products
  • Building Information Modeling: Planning and Managing Construction Projects with 4D CAD and Simulations

  • The ACHR News - January 05, 2026

    ACHR NEWS January 5, 2026, Issue

See More Products

Events

View AllSubmit An Event
  • December 9, 2025

    Beyond Smart Buildings: Why BMS Needs to Move Past Division 23 — For Every Building

    On Demand Let’s reframe Division 25 not as a lofty ideal, but as a practical and alternate approach to specifying facility systems such as a building management systems (BMS).
  • November 19, 2025

    Balance Cost and Efficiency with Self-contained Systems

    On Demand Discover the newest advancements in self-contained systems, including new technologies and design improvements. We will delve into the principles and applications of self-contained Variable Air Volume (VAV) system design, highlighting their benefits and implementation strategies.
View AllSubmit An Event

Related Directories

  • Minvalco Inc. (Mounds View, MN)

  • Tower Equipment Co. Inc.

    Tower Equipment Co Inc. has been serving BAS, HVAC controls and supplies since 1946. With full technical support on everything our clients need.
×

Sign Up. Stay Informed.

The #1 trusted source for the HVACR industry since 1926

SUBSCRIBE
  • RESOURCES
    • Advertise
    • Contact Us
    • Advisory Board
    • Classifieds
    • Submit a Letter
    • Directories
    • Store
  • ACCOUNT CENTER
    • Create an Account
    • Start a Subscription
    • Manage My Account
    • Sign Up for Newsletters
    • Visit Customer Service
    • Update Preferences
  • SERVICES
    • Marketing Services
    • Reprints
    • Market Research
    • List Rental
    • Survey/Respondent Access
  • STAY CONNECTED
    • LinkedIn
    • Facebook
    • Instagram
    • YouTube
    • X (Twitter)
  • PRIVACY
    • PRIVACY POLICY
    • TERMS & CONDITIONS
    • DO NOT SELL MY PERSONAL INFORMATION
    • PRIVACY REQUEST
    • ACCESSIBILITY

Copyright ©2026. All Rights Reserved BNP Media, Inc. and BNP Media II, LLC.

Design, CMS, Hosting & Web Development :: ePublishing