Engineered Systems NEWSCase in Point

Boston Hotel Stays Neighborly With Kitchen Emission Controls

April 29, 2005
The Four Seasons hotel group prides itself on a luxury experience and exceptional service. It aims to provide what it refers to as the "Four Seasons experience" at its resorts and hotels around the world. Fine dining is part of that experience. Kitchen odors, smoke, and grease are not.

The Four Seasons Hotel Boston is a 13-story structure built in 1985, including a spa, pool, and fitness facilities. It overlooks the famed Public Garden and Beacon Hill, within easy reach of the financial and theater districts. The hotel's fine dining room, Aujourd'hui, is considered one of the city's best restaurants.

In 2003, the Four Seasons Hotel Boston began work on an extensive renovation of its first and second floors, adding a courtyard and expanding the two kitchens that served its two restaurants: Aujourd'hui, and the more casual Bristol. Its previous kitchen did not include a system that eliminated cooking odors, smoke, and grease emissions before being released into the atmosphere.

Like A Good Neighbor

The hotel's landlord, Boston Properties, believed that given the Four Seasons' urban location, guest needs, stellar reputation, and local code concerns, it needed such a system with the renovated kitchen. It was also important to Four Seasons that it be regarded as a good neighbor.

In completing the renovation, Four Seasons had multiple requirements. Although the existing facility was being expanded, space for the unit and the connecting ductwork would be an issue. Odor wasn't the sole problem; smoke and grease emissions were also a concern. Four Seasons needed a system that removed these potential pollutants. Because Four Seasons caters to its guests 24 hours a day, minimal downtime for routine cleaning was a necessity. The system also needed to comply with strict federal, state, and local environmental standards, and finally, O&M costs had to be minimized.

In early 2003, Boston Properties had been involved with renovation work at the Prudential Properties, near the Prudential Center. This renovation project had required the use of a state-of-the-art kitchen emissions control system. Boston Properties asked TMP Consulting Engineers to conduct a full-scale review of all the products available for use. The review lasted three months, after which three options were presented to Boston Properties. Boston Properties chose United Air Specialists' Model PSG Smog-Hog system.

So when Boston Properties began work on the Four Seasons renovation, it already had a successful track record with one system. Rather than conduct another wide-ranging product review, it simply told TMP, "Get us another just like it."

With 99.9% efficiency, United Air Specialists' PSG system uses electrostatic precipitation (ESP) technology to filter emissions. ESP also electrically charges microscopic contaminants and captures them magnetically in an aluminum collection cell, releasing only clean air from the system. Exhaust ducting from the kitchen hoods carries the cooking emissions, grease, and odors first to a baffle diffuser, which separates the large particulates. "We joke that it will catch the chef's hat," says Mike Smith, UAS applications engineer for kitchen emissions systems.

The ESP collector then draws the contaminants onto aluminum collection plates within the system; the plates are closely aligned to improve collection efficiency. During this stage, some residual odor may pass through the collection cell, so a V-bank configuration of carbon filters removes remaining odors, releasing only clean air through the discharge.

For routine maintenance, the system is shut down for one hour every 24 hours for a self-cleaning cycle. An in-place, fixed-face, overhead washer cleans collection components without removal.

Creativity Required

To allow the unit to be installed where the Four Seasons wanted, installation of the PSG required some creativity. UAS and its sales reps, NR Metcalf and Associates, designed the system to connect the unit to the facility's existing energy maintenance system and to the ductwork from the parking garage to the roof. This eliminated the need for a long run of expensive and space-consuming ductwork. The ultimate location of the PSG system was the top floor of the hotel's underground garage, and utilized only five parking spaces.

"We allowed the system to be located in the space available, not just where the grease ducting happened to be," said Noel Metcalf of NR Metcalfe, the sales rep for UAS in the region. "We designed around the space they gave us," said UAS' Smith.ES

Share This Story

Looking for a reprint of this article?
From high-res PDFs to custom plaques, order your copy today!

 

Recommended Content

JOIN TODAY
To unlock your recommendations.

Already have an account? Sign In

  • HVAC-enrollment

    The Trades Are Back: HVACR Programs See Nearly 30% Enrollment Spike

    A new wave of future technicians is entering the pipeline.  
    News
    By: Matt Jachman
  • 2025 Top 40 Under 40

    2025 Top 40 Under 40 HVACR Professionals List

    The 11th annual Top 40 Under 40 list highlights those...
    News
    By: Hannah Belloli-Oster
  • LG Ductless Mini-Split Systems

    The 9 Types of Heat Pumps

    As the U.S. moves toward electrification, heat pumps are...
    News
    By: Joanna R. Turpin

More Videos

Today's Boiler

Spring 2026 Issue

Today's Boiler - Spring 2026 Cover

Read More from Today's Boiler

Case in Point Logo

Smarter Hydronic Design for Data Centers - Free Webinar - January 22, 2026

Related Articles

  • scr catalyst

    Emission Controls for Boilers — NOx, CO, VOCs, and Formaldehyde

    See More
  • KITCHEN EMISSION CONTROL

    See More
  • JohnsonControls

    Johnson Controls’ Emission Reduction Targets Approved

    See More

Related Products

See More Products
  • Digital Controls for HVAC Technicians

  • ghpm.png

    Gas Heating: Furnaces, Boilers, Controls, Components

  • Building Information Modeling: Planning and Managing Construction Projects with 4D CAD and Simulations

See More Products
×

Sign Up. Stay Informed.

The #1 trusted source for the HVACR industry since 1926

SUBSCRIBE
  • RESOURCES
    • Advertise
    • Contact Us
    • Advisory Board
    • Classifieds
    • Submit a Letter
    • Directories
    • Store
  • ACCOUNT CENTER
    • Create an Account
    • Start a Subscription
    • Manage My Account
    • Sign Up for Newsletters
    • Visit Customer Service
    • Update Preferences
  • SERVICES
    • Marketing Services
    • Reprints
    • Market Research
    • List Rental
    • Survey/Respondent Access
  • STAY CONNECTED
    • LinkedIn
    • Facebook
    • Instagram
    • YouTube
    • X (Twitter)
  • PRIVACY
    • PRIVACY POLICY
    • TERMS & CONDITIONS
    • DO NOT SELL MY PERSONAL INFORMATION
    • PRIVACY REQUEST
    • ACCESSIBILITY

Copyright ©2026. All Rights Reserved BNP Media, Inc. and BNP Media II, LLC.

Design, CMS, Hosting & Web Development :: ePublishing