search
Ask ACHR NEWS AI
cart
facebook twitter instagram linkedin youtube
  • Sign In
  • Subscribe
  • Sign Out
  • My Account
  • NEWS
  • TECHNOLOGY
    • Heating & Boilers
    • Cooling & Chillers
    • Pumps & Flow Controls
  • SECTORS
    • Commercial
    • Health Care
    • Data Center
    • Educational Facilities
  • DESIGN | CONSTRUCTION
  • OTHER TOPICS
    • High-Performance Buildings & Automation
    • Ventilation and IAQ
    • Commissioning
    • HVAC Retrofits
  • TODAY’S BOILER
    • Today’s Boiler Archives
    • Today’s Boiler Digital Edition
  • MORE
    • Case Studies
    • Podcasts
    • Videos
    • Directory
    • Webinars
    • ES NEWS Store
    • White Papers
  • SIGN UP
  • Back to The NEWS
Engineered Systems NEWSHVAC Engineering News

AMCA Releases Manual for Air Control Devices

AMCA.jpg

The new publication outlines technical procedures and the proper presentation of data for the certification of air-control devices through the AMCA certified ratings program.  IMAGE COURTESY OF AMCA

July 24, 2023

Air Movement and Control Association (AMCA) International Inc. has released AMCA Publication 511-21 (Rev. 12-22), Certified Ratings Program Product Rating Manual for Air Control Devices.

Superseding AMCA Publication 511-21, AMCA Publication 511-21 (Rev. 12-22) outlines technical procedures and the proper presentation of data for the certification of air-control devices through the AMCA certified ratings program. It is to be used in conjunction with AMCA Publication 11-22, Certified Ratings Program Operating Manual.

Used in general ventilation and air-conditioning systems, air-control devices include louvers, dampers, gravity ventilators, round spiral duct, and transverse duct connections. The focus of the 2022 release was the addition of air-leakage-rating requirements (Section 26, new) and air-performance-rating requirements (Section 15) for “linkage-connected economizer dampers,” previously known as “economizer dampers.”

AMCA Publication 511-21 (Rev. 12-22) includes:

  • Updated definitions of “economizer dampers” and “air economizers.”
  • The addition of figures for the three general types of linkage-connected economizer dampers (Annex B, new).
  • The addition of a table of all of the symbols used in the publication (Section 4.2).
  • The addition to most louver sections language clarifying if testing with a drain pan was required.
  • For volume-control dampers, the allowance of extrapolation of air-leakage rating outside the tested height (extrapolation beyond the tested width still is prohibited) (Section 16.2.1.2).

Share This Story

Looking for a reprint of this article?
From high-res PDFs to custom plaques, order your copy today!

 

Recommended Content

JOIN TODAY
To unlock your recommendations.

Already have an account? Sign In

  • HVAC-enrollment

    The Trades Are Back: HVACR Programs See Nearly 30% Enrollment Spike

    A new wave of future technicians is entering the pipeline.  
    News
    By: Matt Jachman
  • 2025 Top 40 Under 40

    2025 Top 40 Under 40 HVACR Professionals List

    The 11th annual Top 40 Under 40 list highlights those...
    HVAC Commercial Market
    By: Hannah Belloli-Oster
  • LG Ductless Mini-Split Systems

    The 9 Types of Heat Pumps

    As the U.S. moves toward electrification, heat pumps are...
    Heat Pumps
    By: Joanna R. Turpin

More Videos

Today's Boiler

Spring 2026 Issue

Today's Boiler - Spring 2026 Cover

Read More from Today's Boiler

Case in Point Logo

Smarter Hydronic Design for Data Centers - Free Webinar - January 22, 2026

Related Articles

  • IndustryNews

    AMCA revises Product Rating Manual for Air Control Devices

    See More
  • Air-Control-Devices Rating Publication 511.png

    AMCA Updates Air-Control-Devices Rating Publication 511

    See More
  • AMCA

    AMCA Updates Air-Control-Devices Rating Publication 511

    See More

Related Products

See More Products
  • HVAC Air Duct Leakage Test Manual, 2nd Edition

  • Manual_SPS_new.jpg

    Manual SPS HVAC Design for Swimming Pools and Spas [ANSI/ACCA 10 Manual SPS - 2010 (RA 2017)]

  • test manual.gif

    HVAC Air Duct Leakage Test Manual

See More Products

Related Directories

  • EB Air Control

    EB Air Control Inc. is a manufacturer of best quality HVAC products in Canada with strong characteristics towards design and technology for "indoor air comfort and quality". Also learn about Spillrite Vacuums Canada.
  • Air Control Supply

×

Sign Up. Stay Informed.

The #1 trusted source for the HVACR industry since 1926

SUBSCRIBE
  • RESOURCES
    • Advertise
    • Contact Us
    • Advisory Board
    • Classifieds
    • Submit a Letter
    • Directories
    • Store
  • ACCOUNT CENTER
    • Create an Account
    • Start a Subscription
    • Manage My Account
    • Sign Up for Newsletters
    • Visit Customer Service
    • Update Preferences
  • SERVICES
    • Marketing Services
    • Reprints
    • Market Research
    • List Rental
    • Survey/Respondent Access
  • STAY CONNECTED
    • LinkedIn
    • Facebook
    • Instagram
    • YouTube
    • X (Twitter)
  • PRIVACY
    • PRIVACY POLICY
    • TERMS & CONDITIONS
    • DO NOT SELL MY PERSONAL INFORMATION
    • PRIVACY REQUEST
    • ACCESSIBILITY

Copyright ©2026. All Rights Reserved BNP Media, Inc. and BNP Media II, LLC.

Design, CMS, Hosting & Web Development :: ePublishing