search
Ask ACHR NEWS AI
cart
facebook twitter instagram linkedin youtube
  • Sign In
  • Subscribe
  • Sign Out
  • My Account
  • NEWS
  • TECHNOLOGY
    • Heating & Boilers
    • Cooling & Chillers
    • Pumps & Flow Controls
  • SECTORS
    • Commercial
    • Health Care
    • Data Center
    • Educational Facilities
  • DESIGN | CONSTRUCTION
  • OTHER TOPICS
    • High-Performance Buildings & Automation
    • Ventilation and IAQ
    • Commissioning
    • HVAC Retrofits
  • TODAY’S BOILER
    • Today’s Boiler Archives
    • Today’s Boiler Digital Edition
  • MORE
    • Case Studies
    • Podcasts
    • Videos
    • Directory
    • Webinars
    • ES NEWS Store
    • White Papers
  • SIGN UP
  • Back to The NEWS
Engineered Systems NEWSHVAC Engineering SectorsData Center HVAC

Managing Airflow at the Room Level Without Busting Your Budget

By Rob Huttemann, Lars Strong, P.E.
airflow

While it’s fairly well understood that the first three levels — or R’s — of airflow management refer to implementing solutions, such as brush grommets, blanking panels, and containment for the raised floor, rack, and row levels, respectively, the room level isn’t quite as simple.

October 27, 2020

Room level airflow management is fraught with misconceptions and half-truths, making it among the least understood aspects of airflow management. Ironically, it’s also among the most important. While it’s fairly well understood that the first three levels — or R’s — of airflow management refer to implementing solutions, such as brush grommets, blanking panels, and containment for the raised floor, rack, and row levels, respectively, the room level isn’t quite as simple. This is primarily because the necessary changes are invisible (except for the occasional displays on cooling units). 

For clarity, room-level airflow management is better defined as cooling optimization, referring to the process of making adjustments to cooling system controls. If done well, this process will improve energy efficiency (resulting in reduced operating costs), cooling capacity, IT equipment reliability, and defer capital expenditures. It’s important to note here that without cooling optimization (i.e., room-level airflow management), any other airflow management solution that has or will be implemented, including the products previously mentioned, is an expense. While these solutions may have improved IT intake air temperatures, the financial and capacity benefits are left on the table. The only way to realize energy savings from airflow management improvements made at the raised floor, rack, and row levels is through cooling optimization. 

And while the process of cooling optimization is typically a manual and iterative process, utilizing solutions such as infrared (IR) thermometers or environmental monitoring will ensure IT intake temperatures do not exceed their recommended or allowable thresholds. Some monitoring solutions can even provide advisement on specific optimization steps that can be taken, but we’ll jump into that later.

 

MATCHING COOLING CAPACITY WITH IT LOAD

Airflow management alone doesn’t save a facility manager money on cooling energy costs; instead, it improves IT equipment intake air temperatures and creates the conditions where changes to the cooling infrastructure are possible. Reason being, if the appropriate airflow management solutions have been correctly implemented at the raised floor, rack, and row levels, there should now be an excess of conditioned supply air in the cold aisles, and all IT equipment intake air temperatures will be excessively low. This is because exhaust air is no longer being mixed with conditioned air and vice versa. The next step is to match the flow rate of conditioned air as closely as possible with the demand flow rate required by the IT equipment. This is done by lowering fan speeds, raising cooling unit temperature set points, or turning cooling units off altogether. This is often an iterative process of making adjustments to the controls, allowing the system to equalize before making additional adjustments if needed. Since data centers are dynamic environments, this will be an ongoing process — not a one-time event. Each time additional airflow management improvements are implemented or significant IT equipment changes occur offers an opportunity to optimize the cooling infrastructure.

 

ROOM-LEVEL AIRFLOW MANAGEMENT (COOLING OPTIMIZATION) BEST PRACTICES

The typical steps that need to be taken to properly match the cooling capacity of your data center with the IT load (i.e., optimize the cooling infrastructure) are:

  • Reduce fan speeds for units with variable frequency drives (VFDs) as much as possible without exceeding the maximum allowable IT equipment intake air temperature.
     
  • Raise cooling unit temperature set points as high as possible without exceeding the maximum allowable IT equipment intake air temperature.
     
  • Expand the allowable relative humidity (RH) band to prevent cooling units from “fighting” with each other (wasting energy because one unit is trying to dehumidify while another is trying to humidify).
     
  • Turn off excess cooling if cooling units don’t have VFDs. If they are equipped with VFDs, energy savings are greater with 10 cooling units running at 50% fan speed than five cooling units running at 100% fan speed.

After any significant airflow management improvement or IT load installation/removal, there’s an opportunity to evaluate these room level controls to ensure efficient operation and sufficient redundant capacity.

 

UTILIZING MONITORING SOLUTIONS TO INFORM OPTIMIZATION DECISIONS

A wise man by the name of Ken Brill once said that when it comes to data center cooling, it’s as simple as ‘power in, heat out always.’ In other words, every kilowatt of power consumed in a computer room becomes a kilowatt of heat that needs to be removed from the computer room and, ultimately, the data center building. This includes all power conversion and distribution losses as well as every kilowatt of electricity consumed by the IT equipment. 

While data center cooling is a science in its own right and can be quite complex, this concept reminds us it can be boiled down to what goes in (in terms of power) must come out (in terms of heat). Therefore, it’s important to monitor the power being demanded by IT equipment (the IT load) to properly match it with the cooling being supplied by cooling units (cooling capacity). Utilizing solutions that can monitor both the power and cooling infrastructure will help in creating this balance.

Secondly, monitoring the thermal performance of a computer room is essential in the cooling optimization process. When making adjustments to the cooling infrastructure, closely monitor the IT equipment intake temperatures to make sure they do not exceed their recommended or allowable limits, as outlined by ASHRAE and/or the manufacturer. While this can be done with an IR thermometer or camera, it may be time-consuming as it can only be done on a per cabinet or aisle basis. One big cautionary remark about using an IR thermometer or camera is that these tools measure surface temperature and not air temperature. If there’s a highly reflective surface, you may experience some incorrect readings due to the reflections. While the use of IR tools can provide an indication of temperature issues, they are not monitoring the temperature of the airflow itself. 

Due to these circumstances, the easiest way to do this at the full room level is to utilize a monitoring solution with sensors placed at the tops and bottoms of all cabinets. This will provide a site-wide view of the data center’s thermal performance. Moreover, while being able to monitor temperatures site-wide is the bare bones of what’s needed, some monitoring solutions have taken this a step further with 3-D visualizations that will display a digital twin of the data center and its real-time thermal performance.

 

OPTIMIZATION WITH AI AND MACHINE LEARNING ALGORITHMS

Artificial intelligence (AI) and machine learning are buzzwords that have served as a panacea to many data center- and IT-related issues. While they may come up short on many of their perceived or marketed promises, airflow management and cooling optimization is where this technology really has a chance to deliver. 

AI can help visualize airflow management improvements at the raised floor, rack, and row levels; analyze data being collected from sensors; and provide advisement on cooling optimization decisions at the room level. There are solutions available that have pioneered this use case for AI and machine learning that couple the monitoring aspect with cooling optimization in the form of a virtual cooling advisor. These solutions may help simplify the cooling optimization process.

 

CONCLUSION

Room level airflow management is not actually airflow management in the literal sense but instead cooling optimization. Nonetheless, room-level airflow management is a necessary step and the only way to realize energy savings from airflow management improvements made at the raised floor, rack, and row levels. Don’t forget that every solution that has been implemented up until the room level is an expense. It’s only when one checks in at the room level and makes cooling infrastructure changes that the benefits may be reaped in the form of cooling energy savings, improved cooling capacity, improved IT equipment reliability, and deferred capital expenditures. Efficiency cannot be purchased; it must be managed. 

Cooling optimization is an iterative and ongoing process, boiling down to matching cooling capacity with the IT load of the computer room. Although this will be a manual process in most cases, utilizing monitoring solutions that give you a look at the power, cooling, and thermal performance of the data center will help guide optimization decisions and, in some cases, advise on specific steps that can be taken.  

Share This Story

Looking for a reprint of this article?
From high-res PDFs to custom plaques, order your copy today!

 

Rob huttemann portrait 900x550

Rob Huttemann is the senior vice president of operations for Critical Environments Group (CEG). He has 30-plus years of industry experience with data center and supporting infrastructure management with specific focus on power, space and storage, cooling, and overall best practices. 

Lars headshot 900x550

Lars Strong, P.E., leads Upsite Technologies’ EnergyLok Cooling Science Services. He is a certified U.S. Department of Energy data center energy practitioner (DCEP) HVAC specialist and has delivered value-added services to domestic and international Fortune 100 companies through the identification and remediation of dilemmas associated with the fluid mechanics and thermodynamics of their data center cooling infrastructure. 

Recommended Content

JOIN TODAY
To unlock your recommendations.

Already have an account? Sign In

  • HVAC-enrollment

    The Trades Are Back: HVACR Programs See Nearly 30% Enrollment Spike

    A new wave of future technicians is entering the pipeline.  
    Training and Education
    By: Matt Jachman
  • 2025 Top 40 Under 40

    2025 Top 40 Under 40 HVACR Professionals List

    The 11th annual Top 40 Under 40 list highlights those...
    News
    By: Hannah Belloli-Oster
  • LG Ductless Mini-Split Systems

    The 9 Types of Heat Pumps

    As the U.S. moves toward electrification, heat pumps are...
    Air Source Heat Pumps
    By: Joanna R. Turpin

More Videos

Today's Boiler

Spring 2026 Issue

Today's Boiler - Spring 2026 Cover

Read More from Today's Boiler

Case in Point Logo

Smarter Hydronic Design for Data Centers - Free Webinar - January 22, 2026

Related Articles

  • Contractor budgeting

    Your Budget is More Than a Math Problem

    See More
  • Kyle Gargaro - Opinion

    This Is Not the Time to Cut Your Advertising Budget

    See More
  • Think Twice Before Cutting Your Advertising Budget

    See More

Related Products

See More Products
  • psywtpm.png

    Psychrometrics Without Tears Manual

  • pewtpm.png

    Pressure Enthalpy Without Tears Manual

  • Building Information Modeling: Planning and Managing Construction Projects with 4D CAD and Simulations

See More Products

Events

View AllSubmit An Event
  • October 14, 2012

    Taking Energy Solutions to the Next Level: Selling Efficiency Effectively

    MSCA LIVE 2012's optional program, Taking Energy Solutions to the Next Level: Selling Efficiency Effectively,will highlight the true value of improving energy efficiency.
View AllSubmit An Event

Related Directories

  • The Graphite Lab (Manufacturer)

    Our AI-powered platform helps HVAC-R businesses speed invoicing, manage online reviews, coach phone reps and much more. Fits seamlessly into your existing software, without disruption.
  • The Graphite Lab (Software/Video)

    Our AI-powered platform helps HVAC-R businesses speed invoicing, manage online reviews, coach phone reps and much more. Fits seamlessly into your existing software, without disruption.
×

Sign Up. Stay Informed.

The #1 trusted source for the HVACR industry since 1926

SUBSCRIBE
  • RESOURCES
    • Advertise
    • Contact Us
    • Advisory Board
    • Classifieds
    • Submit a Letter
    • Directories
    • Store
  • ACCOUNT CENTER
    • Create an Account
    • Start a Subscription
    • Manage My Account
    • Sign Up for Newsletters
    • Visit Customer Service
    • Update Preferences
  • SERVICES
    • Marketing Services
    • Reprints
    • Market Research
    • List Rental
    • Survey/Respondent Access
  • STAY CONNECTED
    • LinkedIn
    • Facebook
    • Instagram
    • YouTube
    • X (Twitter)
  • PRIVACY
    • PRIVACY POLICY
    • TERMS & CONDITIONS
    • DO NOT SELL MY PERSONAL INFORMATION
    • PRIVACY REQUEST
    • ACCESSIBILITY

Copyright ©2026. All Rights Reserved BNP Media, Inc. and BNP Media II, LLC.

Design, CMS, Hosting & Web Development :: ePublishing