Control Freak: Don’t let too much Temperature Control Interfere with Efficiency

Too Much Control? Part 2

By Rebecca T. Ellis, P.E.
Commissioning
May 6, 2019

Last month’s column introduced the concept of giving “too much control” to the building operators through the BAS graphic. I used a simple and fairly obvious example of an air handler with dual temperature set points. This month, I want to share another equally real-life example that is much more subtle.

On a VAV air-handling system, the BAS graphics included the following parameters, all of which were easily adjustable through the user interface:

  • For the central AHU

- Unoccupied setup temperature set point; and

- Unoccupied setback temperature set point.

  • For each VAV zone

- Occupied cooling temperature set point;

- Occupied heating temperature set point;

- Unoccupied setup temperature offset set point; and

- Unoccupied setback temperature offset set point.

The challenge in this system was the fact that each individual VAV zone had its own setup and setback temperature set points; however, those set points were not clearly identified on the BAS graphic. Instead, the parameters displayed on the graphic were unoccupied temperature “offsets.”

The AHU was programmed to start in its unoccupied cooling mode during unoccupied hours whenever the warmest VAV zone temperature rose above the unoccupied setup set point. Similarly, the AHU would start in its unoccupied heating mode during unoccupied hours whenever the coldest VAV zone temperature dropped below the unoccupied setback set point. That’s all very normal these days, including having those two set points adjustable by the building operator.

The challenge in this system was the fact that each individual VAV zone had its own setup and setback temperature set points; however, those set points were not clearly identified on the BAS graphic. Instead, the parameters displayed on the graphic were unoccupied temperature “offsets.” In order to know the VAV zone unoccupied setup temperature set point (i.e., the space cooling set point to which the VAV box would control if the AHU was operational during unoccupied hours), the building operator needed to do the following math in his/her head:

Unoccupied Cooling Temperature Set Point =

Occupied Cooling Temperature Set Point + Unoccupied Setup Temperature Offset Set Point

The same was true for the VAV zone unoccupied heating set point:

Unoccupied Heating Temperature Set Point =

Occupied Heating Temperature Set Point - Unoccupied Setup Temperature Offset Set Point

With both VAV occupied set points adjustable and both VAV unoccupied offset set points adjustable, the unoccupied space heating and cooling temperature set points were all over the board and not explicitly displayed in the BAS graphic.

This is not only confusing and hard to manage, it could also result in excess energy consumption. For example, let’s consider the following situation:

  • The AHU unoccupied setback temperature set point = 65°F; and
  • The coldest VAV zone’s unoccupied heating temperature set point = 60°.

When the coldest VAV zone temperature drops just below 65°, the AHU will start circulating conditioned air to all of its VAV zones. All of the zones will control their individual calculated unoccupied heating temperature set points, including the coldest zone, whose VAV/reheat will control to maintain its space at a minimum 60°. This coldest space will not actually start warming up until its temperature drops below 60°, and then it will modulate its reheat valve to maintain a constant 60°. It will never raise the coldest zone temperature to the 65° AHU setback temperature set point, thus causing the AHU to run continuously for the rest of the scheduled unoccupied period. This is clearly not a very efficient way of maintaining desired minimum building temperatures.

Seeing this much adjustability in the BAS user interface brings to mind one of my favorite axioms, “Just because you can, doesn’t mean you should.” As noted in last month’s column, it might be best to standardize on pop-up instructions on how to make smart choices in those adjustments and the potential implications of making bad choices. It would be even better to incorporate programming that would prevent the operator from adjusting such interrelated set points to inappropriate values relative to each other.

Share This Story

Looking for a reprint of this article?
From high-res PDFs to custom plaques, order your copy today!

 

Rebecca is president of Questions & Solutions Engineering, Inc. She can be reached at rteesmag@qseng.com

Recommended Content

JOIN TODAY
To unlock your recommendations.

Already have an account? Sign In

  • HVAC-enrollment

    The Trades Are Back: HVACR Programs See Nearly 30% Enrollment Spike

    A new wave of future technicians is entering the pipeline.  
    Training and Education
    By: Matt Jachman
  • 2025 Top 40 Under 40

    2025 Top 40 Under 40 HVACR Professionals List

    The 11th annual Top 40 Under 40 list highlights those...
    News
    By: Hannah Belloli-Oster
  • LG Ductless Mini-Split Systems

    The 9 Types of Heat Pumps

    As the U.S. moves toward electrification, heat pumps are...
    HVAC Commercial Market
    By: Joanna R. Turpin

More Videos

Today's Boiler

Spring 2026 Issue

Today's Boiler - Spring 2026 Cover

Read More from Today's Boiler

Case in Point Logo

Smarter Hydronic Design for Data Centers - Free Webinar - January 22, 2026

Related Articles

  • Commissioning

    Control Freak: Do Adjustable Temperature Set Points Lead to Wasted Energy?

    See More
  • Contractor Is a Ventilation Control Freak

    See More
  • How Much CO Poisoning Training Is Too Much?

    See More

Related Products

See More Products
  • Modern Geothermal HVAC Engineering and Control Applications

  • ShowISBNImage.jpg

    Electricity, Electronics, and Control Systems for HVAC, 4/e

  • controltransformersdvd.jpg

    UNDERSTANDING CONTROL TRANSFORMERS

See More Products

Events

View AllSubmit An Event
  • November 19, 2025

    Balance Cost and Efficiency with Self-contained Systems

    On Demand Discover the newest advancements in self-contained systems, including new technologies and design improvements. We will delve into the principles and applications of self-contained Variable Air Volume (VAV) system design, highlighting their benefits and implementation strategies.
View AllSubmit An Event
×

Sign Up. Stay Informed.

The #1 trusted source for the HVACR industry since 1926

SUBSCRIBE
  • RESOURCES
    • Advertise
    • Contact Us
    • Advisory Board
    • Classifieds
    • Submit a Letter
    • Directories
    • Store
  • ACCOUNT CENTER
    • Create an Account
    • Start a Subscription
    • Manage My Account
    • Sign Up for Newsletters
    • Visit Customer Service
    • Update Preferences
  • SERVICES
    • Marketing Services
    • Reprints
    • Market Research
    • List Rental
    • Survey/Respondent Access
  • STAY CONNECTED
    • LinkedIn
    • Facebook
    • Instagram
    • YouTube
    • X (Twitter)
  • PRIVACY
    • PRIVACY POLICY
    • TERMS & CONDITIONS
    • DO NOT SELL MY PERSONAL INFORMATION
    • PRIVACY REQUEST
    • ACCESSIBILITY

Copyright ©2026. All Rights Reserved BNP Media, Inc. and BNP Media II, LLC.

Design, CMS, Hosting & Web Development :: ePublishing