search
Ask ACHR NEWS AI
cart
facebook twitter instagram linkedin youtube
  • Sign In
  • Subscribe
  • Sign Out
  • My Account
  • NEWS
  • TECHNOLOGY
    • Heating & Boilers
    • Cooling & Chillers
    • Pumps & Flow Controls
  • SECTORS
    • Commercial
    • Health Care
    • Data Center
    • Educational Facilities
  • DESIGN | CONSTRUCTION
  • OTHER TOPICS
    • High-Performance Buildings & Automation
    • Ventilation and IAQ
    • Commissioning
    • HVAC Retrofits
  • TODAY’S BOILER
    • Today’s Boiler Archives
    • Today’s Boiler Digital Edition
  • MORE
    • Case Studies
    • Podcasts
    • Videos
    • Directory
    • Webinars
    • ES NEWS Store
    • White Papers
  • SIGN UP
  • Back to The NEWS
Engineered Systems NEWSHVAC Engineering SectorsHVAC Design/Construction ProcessHigh-Performance Buildings & AutomationCommercial HVAC

Specifying Sensors

By Paul Ehrlich P.E.
BuildingAutomation
August 2, 2015

Sensors are a key part of any control system and have an impact on the cost, stability, and accuracy of any control system. But they are also something that frankly gets little attention as we design systems, develop specifications, and write sequences. For many designers, the sensor section sits in the back of the product area of the specification and may get little attention or changes from project to project. In general, that is not all bad, but you should go back and periodically review your sensor specifications. 

 

Temperature Sensors

The vast majority of sensors are used for temperature including zones, duct, pipe, and outdoor air. Sensing technology for BAS is generally either an RTD (resistance to temperature device) or a thermistor. While RTDs are more linear and accurate, thermistors are generally less expensive and work just as well. Here are some key items to note when specifying.

  • Zone sensors. Most suppliers offer a variety of options ranging from a simple blank plate to elaborate digital displays and adjustments. This is an area that is worth discussing with the owner in advance of completing your specification. Suppliers are also generally willing to provide samples for the owner’s approval.
  • Sensor accuracy. For most applications, accuracy of +/- .5?F is adequate. But there are applications where you would want to specify more accurate (and expensive) sensors. This includes any area where you need to hold tight control. Care also needs to be taken where the intent is to measure temperature differentials or deltas. Examples of this include Btu measurement or the inlet and outlet evaporator temperatures on a chiller. When measuring deltas, you should specify that the two sensors are a matched pair.

 

Temperature Sensors

Other sensors commonly specified include humidity, pressure, CO2, flow, and occupancy. Let’s look at some key things to keep in mind about using these sensors.

  • Humidity. You need to carefully consider the application when specifying a humidity sensor.  More accurate sensors are more expensive, but they should be used to control critical environments. Humidity sensors for use in zones can be ordered with integrated temperature sensing eliminating the need to have two sensors on the wall. When sensing outdoor air conditions (i.e. for economizer changeover), we generally like to get one good-quality outdoor air humidity sensor for the building that will be regularly recalibrated.
  • Pressure. For water differential pressure, be sure to specify the needed accessories, such as isolation valves and manifolds, so that the system can be properly started and maintained.
  • CO2, IAQ. These are valuable for strategies such as demand controlled ventilation. Be aware, however, that most CO2 sensors do need to be regularly calibrated.
  • Others. Carefully check your design to see if other sensors such as flow, occupancy, etc., may be required. Many of these are more specialized devices and some additional research may be needed in order to make sure you are specifying the right options.

Like any element of a control design, selecting the right sensors (and making sure that what is specified is being provided) helps assure a quality control installation.  ES

Share This Story

Looking for a reprint of this article?
From high-res PDFs to custom plaques, order your copy today!

 

Paul Ehrlich is the founder and president of Building Intelligence Group LLC, a consulting firm focused on the delivery of energy efficient commercial buildings with a  focus on controls, systems integration, and building to grid integration. For more information, see www.buildingintelligencegroup.com.

Recommended Content

JOIN TODAY
To unlock your recommendations.

Already have an account? Sign In

  • HVAC-enrollment

    The Trades Are Back: HVACR Programs See Nearly 30% Enrollment Spike

    A new wave of future technicians is entering the pipeline.  
    Training and Education
    By: Matt Jachman
  • 2025 Top 40 Under 40

    2025 Top 40 Under 40 HVACR Professionals List

    The 11th annual Top 40 Under 40 list highlights those...
    HVAC Residential Market
    By: Hannah Belloli-Oster
  • LG Ductless Mini-Split Systems

    The 9 Types of Heat Pumps

    As the U.S. moves toward electrification, heat pumps are...
    Heat Pumps
    By: Joanna R. Turpin

More Videos

Today's Boiler

Spring 2026 Issue

Today's Boiler - Spring 2026 Cover

Read More from Today's Boiler

Case in Point Logo

Smarter Hydronic Design for Data Centers - Free Webinar - January 22, 2026

Related Articles

  • Building Automation: Integration: Myths, Lies, and Misconception

    See More
  • Building Automations

    Controls Specification Development

    See More
  • Building Automation: Divisions Of Labor

    See More

Events

View AllSubmit An Event
  • January 14, 2026

    Future-ready HVAC Systems: Transitioning to A2L with New Gas Leak Sensors

    On Demand This session will explore how emerging approaches to leak detection and system monitoring are meeting the demands of modern refrigeration and HVAC applications.
  • December 9, 2025

    Beyond Smart Buildings: Why BMS Needs to Move Past Division 23 — For Every Building

    On Demand Let’s reframe Division 25 not as a lofty ideal, but as a practical and alternate approach to specifying facility systems such as a building management systems (BMS).
View AllSubmit An Event
×

Sign Up. Stay Informed.

The #1 trusted source for the HVACR industry since 1926

SUBSCRIBE
  • RESOURCES
    • Advertise
    • Contact Us
    • Advisory Board
    • Classifieds
    • Submit a Letter
    • Directories
    • Store
  • ACCOUNT CENTER
    • Create an Account
    • Start a Subscription
    • Manage My Account
    • Sign Up for Newsletters
    • Visit Customer Service
    • Update Preferences
  • SERVICES
    • Marketing Services
    • Reprints
    • Market Research
    • List Rental
    • Survey/Respondent Access
  • STAY CONNECTED
    • LinkedIn
    • Facebook
    • Instagram
    • YouTube
    • X (Twitter)
  • PRIVACY
    • PRIVACY POLICY
    • TERMS & CONDITIONS
    • DO NOT SELL MY PERSONAL INFORMATION
    • PRIVACY REQUEST
    • ACCESSIBILITY

Copyright ©2026. All Rights Reserved BNP Media, Inc. and BNP Media II, LLC.

Design, CMS, Hosting & Web Development :: ePublishing