Dehumidification, ductwork ‘keep the powder dry' in AZ

March 30, 2004
Even before the 9/11 attacks, one Arizona army base was already upgrading its ammunition storage facilities in an effort to keep the United States at the ready. Over a six-year period from 1998 to 2002, the base decided to install environmental controls for more than 50 ammunition storage facilities.

Lt. Col. Pete Cullum, the base engineer who handles maintenance and repair of all operational systems, said the project was a three-phase process involving two different mechanical contractors. The first phase started with six dehumidification units in early 1998, but Cullum said these initial units had insufficient capacity to maintain the desired environment and maintain an even climate for the ammunition materials.

Bringing A Whole New Meaning To ‘Critical'

Because of these special concerns, Mechanical Service and Systems (MSS, Midvale, UT) made accommodations for the unique climate demands of the storage facility during second phase. From late 1998 to early 1999, MSS handled phase two of the project to install 27 HCD800 vertical dehumidification units manufactured by PoolPak International. Randy Karren, MSS project manager, worked closely with the local PoolPak representatives at Trane/Salt Lake City to ensure project specifications were met.

Karren said that every storage site needed to have a new mechanical room constructed to house the dehumidification systems. These mechanical rooms were originally designed for horizontal dehumidification units but the vertical orientation of PoolPak equipment fit the existing space. Karren said the installation process went smoothly because PoolPak's supply and returns were easily reconfigured to mate with the existing ductwork. Ductwork was necessary to provide even air distribution into the ammunition storage area for all unit installations.

"The units matched project specifications, offered fair pricing and allowed for a better overall fit," Karren said. Each of the HCD800 units were also equipped with electric heat for precise temperature regulation and a TD2000 programmable microprocessor control system for remote monitoring. Cullum said inline heaters were also utilized in the ducting to assist with additional regulation of temperature controls not handled by the PoolPak systems in order to provide optimum conditions for the unique demands of the ammunition storage environment.

Another important aspect of the installation process was presenting necessary submittal papers to meet critical government specifications. "All the initial criteria passed inspection on the first try and units were delivered on time so we could start work right away without any delays. I'm very happy with their overall performance to date," Karren said. Eighteen of PoolPak's HCD800 units were selected and installed during the final phase of the project from 2001 to 2002.

Low Moisture, High Explosives

Each of the storage/mechanical areas needed to maintain a 45% rh with 70°F winter temperatures and 80° during summer months. Brian Boyer, vice president, Boyer Metal (Flagstaff, AZ), said PoolPak International's high capacity dehumidification (HCD) units satisfied these requirements. The HCD800 has a supply airflow of 1,100 to 2,400 cfm, with a maximum outside airflow of 800 cfm. Ideal for high-moisture locations, the standard HCD operates as a reheat unit that dehumidifies and returns warm, dry air to a conditioned enclosure through a hot gas reheat coil.

Boyer's installation concerns involved the ducting. "We had to cut into concrete buildings dating back to the 1940s and 1950s in order to place the return air ducts between the two structures. The other difficulty came from the ducting itself, which was too thin for supporting the weight of dirt on the outside wall and crushed the piping." Because of that, Boyer said they had to replace 1/4-in.-thick fiberglass reinforced spiral pipe with 1/2-in.-thick FPR to rectify the problem.

Cullum is pleased with the final result, now that the PoolPak International dehumidification systems have been operating from two to five years without any downtime thus far. "From a maintenance point of view, the units are easy to work with on a regular repair schedule and offer optimal efficiency." ES

Share This Story

Looking for a reprint of this article?
From high-res PDFs to custom plaques, order your copy today!

 

Recommended Content

JOIN TODAY
To unlock your recommendations.

Already have an account? Sign In

  • HVAC-enrollment

    The Trades Are Back: HVACR Programs See Nearly 30% Enrollment Spike

    A new wave of future technicians is entering the pipeline.  
    Training and Education
    By: Matt Jachman
  • 2025 Top 40 Under 40

    2025 Top 40 Under 40 HVACR Professionals List

    The 11th annual Top 40 Under 40 list highlights those...
    HVAC Commercial Market
    By: Hannah Belloli-Oster
  • LG Ductless Mini-Split Systems

    The 9 Types of Heat Pumps

    As the U.S. moves toward electrification, heat pumps are...
    Air Source Heat Pumps
    By: Joanna R. Turpin

More Videos

Today's Boiler

Spring 2026 Issue

Today's Boiler - Spring 2026 Cover

Read More from Today's Boiler

Case in Point Logo

Smarter Hydronic Design for Data Centers - Free Webinar - January 22, 2026

Related Articles

  • How WonderFlange helps round ductwork keep its shape

    See More
  • Dry in the desert: duct liner addresses medical center's moisture concerns

    See More
  • hvac-dispatcher.jpg

    The Most Undervalued Role in HVAC: Why Dispatchers Are the Ones Who Actually Keep the Company Running

    See More

Related Products

See More Products
  • EHEP002028.jpg

    Principles of Heating, Ventilation, and Air Conditioning in Buildings, 1st Edition

  • 0880690186-228x228.jpg

    Airflow in Ducts

  • Lessons Learned in a Boiler Room: A common sense approach to servicing and installing commercial boilers

See More Products

Events

View AllSubmit An Event
  • May 19, 2026

    Addressing IAQ, Humidification, and Dehumidification Issues for Your Customers

    On Demand This webinar from The ACHR NEWS will examine how IAQ and dehumidification strategies differ, and overlap, across residential and commercial applications.
View AllSubmit An Event

Related Directories

  • Dry Air Ltd.

    DRYAIR is the UKs leading air humidity control and desiccant dehumidifier specialist. Engineered for efficiency, built to last.
×

Sign Up. Stay Informed.

The #1 trusted source for the HVACR industry since 1926

SUBSCRIBE
  • RESOURCES
    • Advertise
    • Contact Us
    • Advisory Board
    • Classifieds
    • Submit a Letter
    • Directories
    • Store
  • ACCOUNT CENTER
    • Create an Account
    • Start a Subscription
    • Manage My Account
    • Sign Up for Newsletters
    • Visit Customer Service
    • Update Preferences
  • SERVICES
    • Marketing Services
    • Reprints
    • Market Research
    • List Rental
    • Survey/Respondent Access
  • STAY CONNECTED
    • LinkedIn
    • Facebook
    • Instagram
    • YouTube
    • X (Twitter)
  • PRIVACY
    • PRIVACY POLICY
    • TERMS & CONDITIONS
    • DO NOT SELL MY PERSONAL INFORMATION
    • PRIVACY REQUEST
    • ACCESSIBILITY

Copyright ©2026. All Rights Reserved BNP Media, Inc. and BNP Media II, LLC.

Design, CMS, Hosting & Web Development :: ePublishing