ACHR News
search
Ask ACHR NEWS AI
cart
facebook twitter instagram linkedin youtube
  • Sign In
  • Subscribe
  • Sign Out
  • My Account
ACHR News
  • NEWS
    • Breaking News
    • New HVAC Products
    • Featured Products
    • Manufacturer Reports
    • HVAC Data
    • Legislation
    • ACHR NEWS Centennial
  • RESIDENTIAL
    • Air Conditioners
    • Furnaces
    • Residential Heat Pumps
    • Ductless
    • Residential IAQ
    • Testing, Monitoring, Tools
    • Components & Accessories
  • COMMERCIAL
    • Air Handlers
    • Rooftop Units
    • Chillers and Cooling Towers
    • Commercial Heat Pumps
    • Boilers and Hydronics
    • VRF/Ductless
    • Commercial IAQ
  • REFRIGERATION
    • Refrigerants
    • Refrigerant Regulations
    • Leak Management
  • CONTRACTOR PRO
    • Geothermal
    • Homeowner Study
    • VRF and VRV Ductless
    • Unitary Trends
  • EDUCATION
    • Training and Education
    • Business Management
    • Service and Maintenance
    • Continuing Education
    • Market Research >
      • HVAC Brand Awareness Report
      • VRV, VRF, VRVZ Report
      • Unitary Trends Report
      • Water Heat Professionals Report
    • Webinars
    • Sponsor Insights
    • eProducts Info
    • White Papers
  • EVENTS
    • HVAC Contractor Forum
    • Industry Events and Webinars
  • MEDIA
    • Videos
    • AHR Expo 2025 Videos
    • Podcasts >
      • ACHR News Podcast
      • HARDI Podcasts
      • AHR Expo Podcasts
      • ACCA Podcasts
    • Interactive Spotlights
    • Quizzes
    • eBooks
    • HVAC Talkback
  • HVAC GROUP
    • ACHR NEWS >
      • Current Issue
      • Digital Edition
      • Subscribe
    • Distribution Trends
    • SNIPS NEWS >
      • Join SNIPS NEWS
    • Engineered Systems News >
      • Join ES News
    • HVACR Directory
    • Contests
    • Newsletters
    • Contact
    • Advertise
    • My Account
HVAC ContractingService and Maintenance

Btu Buddy 60: High Head Pressure and Power Consumption

By Bill Johnson
March 24, 2008

Bob is a service technician who is well trained and nationally certified. However, he sometimes suffers from the same confusion that all technicians occasionally do - the facts that he gathers may or may not point to the obvious cause of the problem or the best solution. But Bob has something that no one else has. He recalls his long-time HVACR mentor and imagines him accompanying him as “Btu Buddy,” someone who reminds him to take time to stop and think before rushing to judgment, helping keep him on the right track, even with facts that are confusing.

Bob and Btu Buddy got together for lunch at a place where they could take their time and talk about why high head pressure seems to drive up the power consumption of a compressor. Bob started if off by saying, “I have had several complaints of high power bills, particularly with heat pumps, and have discovered that dirty indoor coils or reduced airflow had driven the head pressure up and the customer discovered it from excess power bills. They then called the company and asked for service. This doesn’t seem to happen in the cooling season, only in the heating season. What is the difference and why is this happening?”

Btu Buddy began the explanation: “The simple and easy answer is to say that a compressor in a system is responsible for raising the pressure in the system from the saturated suction pressure to the saturated discharge pressure. The more that it has to raise the pressure, the more it costs. Now for why.

“Let’s take this one component at a time. An air conditioner has a 40°F boiling temperature for R-22 that creates a suction pressure of about 70 psig, rounded up from 68.5 psig, at design conditions. This is the low-pressure side of the system.

“The condenser normally has a condensing temperature of 125°F that creates a head pressure of 278 psig of head pressure at design conditions. This is considered the high-pressure side of the system.

Figure 1. Notice that the suction pressure at the evaporator is 70 psig and the liquid line pressure is 278 psig. The compressor created this pressure difference. (Figures are from Refrigeration & Air Conditioning Technology, 5th Edition, by William Whitman, William Johnson, and John Tomczyk, published by Delmar Cengage Learning.) (Click on the image for an enlarged view.)

“The compressor has to lift the refrigerant pressure from the low-pressure side to the high-pressure side. In gauge pressure readings, that is a lift of 209.5 psig (278.5 – 70 = 209.5) (Figure 1). It can easily be seen that if you raise the amount of lift, you must raise the amount of work done. That is the short version of what happens.”

Bob said, “This sounds like it could get serious.”

Btu Buddy said, “Yes, it is quite detailed. You remember that we live in an atmosphere of air. Actually, you could say that we live at the bottom of an ocean of air. Air is matter, explained by the fact that it has weight and takes up space. Actually this ocean of air above us creates a pressure at sea level, during standard conditions, of 14.696 pounds per square inch. You notice it when you drive up a mountain; your ears pop. The pressure on the outside of your body becomes less, and your ears pop when the pressures equalize. You will also recall from your technical school days that your manifold gauges read atmospheric pressure as 0 psig. When we start working with the details of compressor lift, we have to take atmospheric pressure into consideration and deal with pounds per square inch absolute (psia). For practical purposes, you just add atmospheric pressure to your gauge reading to get psia.”

“Wow,” said Bob, “fill me in slowly so I don’t get lost.”

Btu Buddy then said, “When engineers talk about how a compressor works with pressure, they use a term called compression ratio. Compression ratio is the absolute discharge pressure divided by the absolute suction pressure. In formula form it would look like this: CR = absolute discharge pressure / absolute suction pressure. This is a ratio of the volume of refrigerant in a cylinder at bottom dead center to the volume of refrigerant in the cylinder at top dead center. The refrigerant volume is compressed from a large volume to a smaller volume.

“Suppose your gauges read design conditions, 278 psig discharge pressure and 70 psig suction pressure. That would mean that:

absolute discharge pressure is 278 + 14.696 = 292.7 psia

absolute suction pressure is 70 + 14.696 = 84.7 psia

“Placing this in the formula:

CR = 292.7 / 84.7 = 3.46:1 ratio of inlet to outlet.

If this were cubic feet, we would have 3.46 cubic feet of refrigerant compressed to 1 cubic foot during the compression process.

“If we raise the discharge pressure to 350 psig + 14.696 / 70 + 14.696 we get a new CR.

CR = 364.7 / 84.7 = 4.3:1 ratio of inlet to outlet.

You can say that enough work was done to compress the volume of refrigerant gas from 4.3 to 1 in this compression process.

“The compression ratio can also be changed by lowering the suction pressure. For example, suppose we lower the suction pressure to 60 psig and keep the same design discharge pressure.

CR = 278 + 14.696 / 60 + 14.696
CR = 292.7 / 74.7
CR = 3.9:1 ratio of inlet to outlet.

If you raise the discharge and lower the suction:

CR = 350 + 14.696 / 60 + 14.696
CR = 364.7 / 74.7
CR = 4.8:1 ratio of inlet to outlet.

“Now, lets look at a heat pump and see what we may get on a cold day. Let’s suppose the head pressure is 210 psig and the suction pressure is 21 psig.

CR = 210 + 14.696 / 21 + 14.696
CR = 224.696 / 35.696
CR = 6.3:1 ratio of inlet to outlet.

That is a lot of conversation that tells you to keep the head pressure as low as practical and keep the suction pressure as high as practical. When either pressure gets out of the design parameters, there will be less efficiency.”

Bob asked, “How does that fit in with today’s practices for service technicians and their service duties?”

Btu Buddy said, “Our job is to keep coils clean, both indoors and outdoors. Now let’s get back to the heat pump that we worked on yesterday that had a dirty coil in the winter. Suppose it had a head pressure of 300 psig and a suction pressure of 21 psig.

CR = 300 + 14.696 / 21. + 14.696
CR = 314.696 / 35.696
CR = 8.8:1 ratio of inlet to outlet.

Figure 2. Notice the size of the evaporator and the condenser. The condenser must reject the heat of compression from the compressor as well as the heat absorbed by the evaporator. (Click on the image for an enlarged view.)

You finally reach a point that the lift is too much to be practical. The compressor is working very hard and not getting much done so it has to run longer and the strip heat will also be operating more, so the power bill goes up.

“The job was a heat pump and heat pumps have a little different slant on the problem. Typically an air conditioner condenser is about 25 percent larger than the evaporator because the condenser must eliminate about 25 percent more heat than the evaporator absorbs into the system (Figure 2). This heat is called ‘heat of compression.’ Compression ratios of over 12:1 are prohibitive for compressors because as the compression ratio rises, the discharge gas temperature rises. Oil is always present in discharge gas and oil particles begin to break down at temperatures of over 250°F. These high compressor temperatures are asking for a problem.

“I don’t know if you have noticed, but heat pumps use the same indoor and outdoor sizes as air conditioners.”

Bob then said, “When they reverse the cycle for winter time operation, the condenser area is automatically 25 percent smaller than the evaporator. That can’t be good.”

Btu Buddy said, “It works out that it is good because it is harder to extract heat from the colder outdoor air and the coil really needs to be larger. The indoor coil being smaller is good because it raises the air temperature to the structure. Typically, the supply air from a heat pump is no greater than 100°F. You have been on a service call where the customer complained about drafts. If the outlet air were any cooler, even though it was heating the house, there would be more complaints.”

Figure 3. There is always volume left at the top of the cylinder (clearance volume) in a reciprocating compressor. The refrigerant compressed into this clearance volume will expand when the piston starts back down. No refrigerant will enter the compressor cylinder until the pressure in the cylinder is less than the pressure in the suction line. (Click on the image for an enlarged view.)

Bob asked, “What else do I need to know about this?”

Btu Buddy then explained, “The heat pump we were working on yesterday was a reciprocating compressor. High compression ratios are even worse on reciprocating compressors because of the clearance volume at the top of the cylinder on the upstroke of the piston. When a reciprocating compressor piston reaches the top of the stroke, there is a little refrigerant trapped at the top, between the piston and the cylinder head (Figure 3). All reciprocating compressors have this clearance volume so the piston will not hit the cylinder head. When the piston starts down, this tiny bit of gas re-expands in the cylinder on the down stroke. The cylinder cannot start filling until the pressure in the cylinder is less than the pressure on the low side of the system. When the head pressure is higher than normal, there is more than normal refrigerant gas trapped in the clearance volume of the compressor. The compressor efficiency just went down even more than what was caused by the compression ratio.”

Bob said, “Boy, this is really a lot of information.”

Btu Buddy said, “When you buy a huge cup of iced tea in the summer at lunch, you drink it a sip at a time. It is hot outside and you are really thirsty. I bet it takes awhile to drink it all. This is how your education is. You take it a little at a time and over time you really become educated; just like the cup of tea, you keep reaching for the bottom, only with education, there is no bottom. This keeps you interested all of your life.”

Bob then said, “Thank goodness for good resources, such as other technicians, books, and the Internet.”

Publication date: 03/24/2008

Share This Story

Looking for a reprint of this article?
From high-res PDFs to custom plaques, order your copy today!

 

Active in the HVACR industry since the 1950s, Bill Johnson graduated in gas fuel technology and refrigeration from the Southern Technical Institute, a branch of Georgia Tech (now known as Southern Polytechnic Institute). He taught HVAC classes at Coosa Valley Vocational & Technical Institute for four years. He moved on to become service manager for Layne Trane, Charlotte, N.C. He taught for 15 years at Central Piedmont Community College, part of this time as program director. He had his own business for five years doing installation and service work. Now retired, he is the author of Practical Heating Technology and Practical Cooling Technology, and continues as a co-author of Refrigeration & Air Conditioning Technology, seventh edition, all published by Delmar Cengage Learning. For more information, he can be reached at 704-968-0000 or thebillj1@gmail.com.

Btu Buddy Notebook is a collection of more than 50 service call scenarios in book form covering both cooling season and heating season troubleshooting. For more information and to purchase the book, visit the HVACR Industry Store.

Recommended Content

JOIN TODAY
To unlock your recommendations.

Already have an account? Sign In

  • HVAC-enrollment

    The Trades Are Back: HVACR Programs See Nearly 30% Enrollment Spike

    A new wave of future technicians is entering the pipeline.  
    Training and Education
    By: Matt Jachman
  • 2025 Top 40 Under 40

    2025 Top 40 Under 40 HVACR Professionals List

    The 11th annual Top 40 Under 40 list highlights those...
    HVAC Contracting
    By: Hannah Belloli-Oster
  • LG Ductless Mini-Split Systems

    The 9 Types of Heat Pumps

    As the U.S. moves toward electrification, heat pumps are...
    HVAC Residential Market
    By: Joanna R. Turpin
Subscription Center
  • Create an Account
  • Start a Subscription
  • Manage My Account
  • Sign Up for Newsletters
  • Visit Customer Service
  • Update Preferences

More Videos

Sponsored Content

Sponsored Content is a special paid section where industry companies provide high quality, objective, non-commercial content around topics of interest to The News audience. All Sponsored Content is supplied by the advertising company and any opinions expressed in this article are those of the author and not necessarily reflect the views of The News or its parent company, BNP Media. Interested in participating in our Sponsored Content section? Contact your local rep!

close
  • Piggy Bank
    Sponsored byWatercress Financial

    Energy Prices, Inflation, and HVAC: What Today’s Homeowners Care About

  • Refrigerated Food
    Sponsored bySolstice Advanced Materials

    R-455A Refrigeration: A Cold Storage Solution for the Future

  • Airex Rooftop Units
    Sponsored byAirex Manufacturing Inc

    Consolidating Roof Penetrations: A Growing Trend in Multifamily HVAC Design

Popular Stories

Refrigerants-and-gauge.jpg

HVAC Industry Warns of Counterfeit Refrigerants Entering U.S. Supply Chain

Lennox equipment

Platinum Equity to Sell Heat Controller to Lennox

HVAC Minute retail refrigeration system

EPA Final Rule’s Impact on R-410A Deadlines

HVAC-tech-van.jpg

Report: Only 65% of HVAC Technician Time is Billable Hours

Dealer_Couple2_Kitchen_Estimate.jpg

Predicting the Next Service Call

View The ACHR NEWS
Centennial Anniversary Timeline

The ACHR News Timeline Chart
Submit a Letter
Submit a letter to our editors.

Events

November 6, 2025

Next-Gen Data Center Cooling: HVAC Innovation and Real-World Solutions

On Demand As AI workloads and high-density computing push traditional cooling methods to their limits, the data center industry is accelerating the adoption of next-generation HVAC technologies.

July 28, 2026

How Top Home Services Companies Turn Every Conversation Into Predictable Revenue

In this webinar, we'll outline how top contractors are turning every conversation into predictable revenue by coaching every comfort advisor visit, not just the ones a manager rides along on.

View All Submit An Event

Poll

Summer Staff

Are you fully staffed for the summer season?
View Results Poll Archive

Products

BNI Mechanical/Electrical Square Foot Costbook, 2026 Edition

BNI Mechanical/Electrical Square Foot Costbook, 2026 Edition

See More Products
Designing Systems Using A2L Refrigerant - Free Webinar - 7/22/2026

Related Articles

  • Btu Buddy 65: Chiller With High Head Pressure

    See More
  • Btu Buddy 40: High Head Pressure, Air in System

    See More
  • Btu Buddy 59: High Power Bills With a Heat Pump

    See More

Related Directories

  • Powered Aire Inc.

    Manufacturer of high-performance stainless-steel air curtains for the commercial, industrial, retail, food service, material handling, overhead door, automatic door and cold storage industries.
×

Sign Up. Stay Informed.

The #1 trusted source for the HVACR industry since 1926

SUBSCRIBE
  • RESOURCES
    • Advertise
    • Contact Us
    • Advisory Board
    • Classifieds
    • Submit a Letter
    • Directories
    • Store
  • ACCOUNT CENTER
    • Create an Account
    • Start a Subscription
    • Manage My Account
    • Sign Up for Newsletters
    • Visit Customer Service
    • Update Preferences
  • SERVICES
    • Marketing Services
    • Reprints
    • Market Research
    • List Rental
    • Survey/Respondent Access
  • STAY CONNECTED
    • LinkedIn
    • Facebook
    • Instagram
    • YouTube
    • X (Twitter)
  • PRIVACY
    • PRIVACY POLICY
    • TERMS & CONDITIONS
    • DO NOT SELL MY PERSONAL INFORMATION
    • PRIVACY REQUEST
    • ACCESSIBILITY

Copyright ©2026. All Rights Reserved BNP Media, Inc. and BNP Media II, LLC.

Design, CMS, Hosting & Web Development :: ePublishing