Troubleshooting Challenge: A Heat Pump That's Not Operating

January 10, 2011
This troubleshooting situation is a look ahead to the upcoming cooling season. Our customer has called to say that their heat pump “isn’t cooling at all,” and while the outdoor temperature is only in the mid 80’s, it’s quite uncomfortable in the house. You find that the underlying reason is that the compressor and outdoor fan motor aren’t operating.
Read More

Troubleshooting Challenge: A Gas Furnace That's Heating Intermittently

November 8, 2010
When the customer calls for service, he tells you that when things got very cold in the house, he disconnected the power supply to the unit, and then, after turning the 120-volt service switch back on, the operation seemed normal and the house got warm “for a day or so.” But the failure repeated.
Read More

Troubleshooting Challenge: A Small Room-Size Heat Pump That's Not Heating

September 6, 2010
In this troubleshooting situation, we have a customer who has called to say that their 12,000 Btu through-the-wall unit is “blowing cool air even though it’s set for heat.” The unit is a heat pump with a three-speed motor. It operates on 240 vac.
Read More

Troubleshooting Challenge: A Follow-Up on a Restaurant Cooler

July 5, 2010
Your role in this month’s troubleshooting situation is as the follow-up technician on a problem that was made worse by the technician who preceded you. When the restaurant manager originally called for service, the complaint was that their small walk-in cooler “wasn’t keeping as cool as usual.” Now it’s “hardly cooling at all.”
Read More

Troubleshooting Challenge: A Condensing Unit Problem

May 10, 2010
This time around our problem centers on a split-system air conditioner. The condensing unit is 240-volt, single-phase, and the indoor air handler (which our customer is able to tell us is “blowing warm air”) consists of a standard gas furnace and an A-coil housed above the furnace plenum.
Read More

Troubleshooting Challenge: A Refrigeration System With a History of Compressor Failure

March 8, 2010
Your troubleshooting situation this time around relates to a walk-in refrigeration system in a busy restaurant that has experienced a compressor failure… specifically a mechanical failure. And it’s not the first time.
Read More

Troubleshooting Challenge: A Modular A/C Unit That's Not Cooling

January 4, 2010
In this month’s troubleshooting situation we’re taking you to a modular classroom with a heating/cooling unit that employs resistance-type elements for the heating mode, and a direct expansion system for cooling. The complaint is that there is “very little cooling” being accomplished.
Read More

Troubleshooting Challenge: A Furnace That's Not Heating the Whole House

November 9, 2009
In this troubleshooting situation, we have a customer who is complaining about one of the bedrooms in their home, specifically that the gas furnace doesn’t warm the room properly. When you arrive, you find that the bedroom in question is the furthest from the furnace, and that the duct system is an extended plenum system.
Read More

Troubleshooting Challenge: A Soda Vending Machine That's Not Performing Properly ... Sometimes

September 7, 2009
This month’s problem piece of equipment is a soda vending machine. The complaint from the customer, who has positioned the unit outside their small motel, is that while the soda seems to be properly cooled during the middle of the day, there are times when the product is warmer than desired.
Read More

Troubleshooting Challenge: A Reach-In Refrigerator That's Not Keeping Food Cool

July 6, 2009
In this issue’s troubleshooting situation, the problem unit we’re facing is a reach-in refrigerator in a restaurant and the customer’s description of the problem is that they discovered spoiled food in the cabinet when they arrived early in the morning prior to opening.
Read More

Multimedia

Videos

Image Galleries

2014 MCAA Annual Convention

Scenes from the 2014 MCAA Annual Convention in Scottsdale, Ariz.

Podcasts

NEWSmakers: Julian Scadden

Training is an ongoing process. Julian will discuss how you can generate maximum return on time and energy invested training by following a three part process. Listen to this podcast to get expert tips on training, tracking and follow up. 

More Podcasts

ACHRNEWS

NEWS 04-21-14 cover

2014 April 21

Check out the weekly edition of The NEWS today!

Table Of Contents Subscribe

SERVICE CALLS POLL

Which statement on service calls best applies to your business?
View Results Poll Archive

HVACR INDUSTRY STORE

plumbing-hvac.gif
2014 National Plumbing & HVAC Estimator

Every plumbing and HVAC estimator can use the cost estimates in this practical manual!

More Products

Clear Seas Research

 

Clear Seas ResearchWith access to over one million professionals and more than 60 industry-specific publications, Clear Seas Research offers relevant insights from those who know your industry best. Let us customize a market research solution that exceeds your marketing goals.

DON'T MISS A THING

Magazine image
 
Register today for complete access to ACHRNews.com. Get full access to the latest features, Extra Edition, and more.

STAY CONNECTED

facebook icontwitter iconyoutube iconLinkedIn i con