Articles by Bill Johnson

Btu Buddy 95: Compressor Motor Overload

February 21, 2011
Bob got a call from the dispatcher to go to an office building that has a 3-ton heat pump compressor that has been shutting off after startup. The fan would continue to run. The building maintenance man said that he had observed the shutting down of the compressor several times.
Read More

Btu Buddy 94: A Heat Pump That's Not Getting Up to Temperature

January 24, 2011
Bob has gone on a service call where the customer is complaining that her house is not getting up to temperature. The house was heated with a heat pump with three stages of auxiliary strip heat. Bob removed the panel to the strip heat and found one of the units was not pulling current.
Read More

Btu Buddy 93: Pneumatic Controls Review

December 20, 2010
Bob and Btu Buddy have gotten together for a review of their last service call, which involved a control system that Bob was not very familiar with - pneumatic controls. Bob asked, “Why would anyone want to use air as the power source to operate the controls for a building?”
Read More

Btu Buddy 92: Pneumatic Control System

November 22, 2010
The customer’s complaint on this call was an overall overheating of his building. The manager told Bob, “We arrived this morning and the entire building was hot and keeps getting hotter.” He led Bob to the basement where there was a boiler. Bob found that the system had pneumatic controls.
Read More

Btu Buddy 91: Underground Refrigerant Leak - Part 2

October 18, 2010
Bob’s service call yesterday involved a leaking underground refrigerant piping system. Bob replaced the refrigerant lines, leak tested the lines, and left them yesterday afternoon under 150 psig of pressure. He has now returned to the job the next day to see if the pressure held and to check for moisture in the system.
Read More

Btu Buddy 90: Underground Refrigerant Leak

September 20, 2010
Bob was called to a job that had a no cooling complaint. This was a new customer and Bob wanted it to be a good experience for the customer. It was a small stand-alone store building with a 3-ton cooling only unit. Bob determined this was a low charge problem. He installed his gauges and discovered the unit did not have any refrigerant in it.
Read More

Btu Buddy 89: Condenser Under Water

August 23, 2010
The dispatcher called Bob and sent him to a job that really sounded like a problem. There had been a hard rain and a customer had a condensing unit that had been under water that morning due to high water from a creek behind his house. The owners were on a fixed income and wanted to get the repair at the best possible price.
Read More

Btu Buddy 88: Follow-Up on a Dirty Water Cooled Condenser

July 19, 2010
Bob has been on a job at a convention center with a 100-ton water cooled condenser. The owners are anxious for Bob to get the a/c back on, but Bob said the tubes must be cleaned before the unit will run. He has called the shop and asked for a helper and a tube cleaning machine to help him get the unit running as fast as possible.
Read More

Btu Buddy 87: Dirty Water Cooled Condenser

June 21, 2010
The dispatcher calls Bob with an urgent service call from the city’s convention center. A convention is going on and the air conditioner is off, and it re-starts but only runs a short time and shuts off again. The maintenance man said he had to reset the high pressure control to get it started. Btu Buddy assists in troubleshooting the system.
Read More

Btu Buddy 86: Flooded Compressor Discussion

May 24, 2010
Bob and Btu Buddy get together for breakfast to discuss their last service call, which concerned a compressor that had liquid refrigerant flooding back to it. Bob had asked a couple of questions while they were leaving the job. Btu Buddy then proceeds to answer Bob’s questions.
Read More

Multimedia

Videos

Image Galleries

2014 ACI Home Performance Conference

The 2014 ACI National Home Performance Conference & Trade Show was held in Detroit.

Podcasts

NEWSMakers: Doug Dougherty

Doug Dougherty, president and CEO of the Geothermal Exchange Organization (GEO) joins the program to discuss the latest happenings with GEO, including the drive to get included in state and federal definitions of renewable energy, plus the future of geothermal.  Posted on July 25.

More Podcasts

ACHRNEWS

NEWS 07-21-14 cover

2014 July 21

Check out the weekly edition of The NEWS today!

Table Of Contents Subscribe

R-22 PHASEOUT POLL

Some in the industry are calling for the EPA to halt production of R-22 as of 2015. What do you think?
View Results Poll Archive

HVACR INDUSTRY STORE

plumbing-hvac.gif
2014 National Plumbing & HVAC Estimator

Every plumbing and HVAC estimator can use the cost estimates in this practical manual!

More Products

Clear Seas Research

 

Clear Seas ResearchWith access to over one million professionals and more than 60 industry-specific publications, Clear Seas Research offers relevant insights from those who know your industry best. Let us customize a market research solution that exceeds your marketing goals.

DON'T MISS A THING

Magazine image
 
Register today for complete access to ACHRNews.com. Get full access to the latest features, Extra Edition, and more.

STAY CONNECTED

facebook icontwitter iconyoutube iconLinkedIn i con