Bob is a service technician who is well trained and
nationally certified. However, he sometimes suffers from the same confusion
that all technicians occasionally do - the facts that he gathers may or may not
point to the obvious cause of the problem or the best solution. But Bob has
something that no one else has. He recalls his long-time HVACR mentor and
imagines him accompanying him as “Btu Buddy,” someone who reminds him to take
time to stop and think before rushing to judgment, helping keep him on the
right track, even with facts that are confusing.
Figure 1. This is a rotating wire mesh humidifier. As the mesh
turns, it picks up water and rotates it into the air stream for evaporation.
(Figures are from Refrigeration & Air Conditioning Technology, 5th
Edition, by William Whitman, William Johnson, and John Tomczyk, published by
Delmar Cengage Learning.)
Bob and Btu Buddy have sat down for a lunch discussion about
humidifiers and Bob asked a question: “Aren’t all humidifiers about the same?”
Btu Buddy responded, “They are all the same in that they add
moisture to the air. Different homes have different types of heating systems.
The home we were in today had a heat pump. When adding moisture to the heat
pump system, you must take into consideration that the air temperature leaving
the heat pump is not nearly as hot as air in a fossil fuel system, such as gas
or oil. The discharge air temperature in a heat pump is never more than about 100°F,
whereas a fossil fuel system may have discharge air temperatures of 150°F. The
moisture must be evaporated into the air stream. One of the factors that you
must remember is that all water contains some form of minerals. When
evaporation occurs, these minerals must be considered. Let’s look at some ways
that water is evaporated in various humidifiers.

Figure 2. This is a plenum-mounted humidifier that uses pads to
wick water up into the air stream for evaporation.
“First, evaporative humidifiers - These humidifiers typically use
some sort of media to give the moisture more surface area because the larger
the surface area, the more evaporation you can accomplish in the smallest
space. Different forms of media are used for evaporation. Some units have a
large rotating drum that turns through a water reservoir. Some of these are
located under the plenum (Figure 1). The rotating media is partially under
water and the rest of the media is in the air stream. Some of the units have
absorbent pads that are partially under water that act like a wick to pull
water up into the media that is in the air stream (Figure 2). These units
perform better in the discharge air stream. The warmer the air stream, the more
moisture will evaporate. Since the discharge air plenum is the best place, the
plenum must be in the right configuration for installing these units. Some manufacturers
have designed units that will mount directly over the air handler and do no
have to be mounted under the duct.
“A bypass humidifier can be installed where the plenum is not the
right configuration for an under the duct system. The bypass humidifier uses a
small duct from the supply air routed through the unit and over the media and
into the return air (Figure 3). The supply air is under more pressure and
forces warm air through the unit for evaporation.

Figure 3. This is a bypass humidifier; hot air from the hot air
plenum is pushed through the humidifier and returned to the return air side of
the furnace. A – Picture of the unit. B – Cutaway of the unit. C – Different
configurations using it as a plenum mount. (Click on the image for an enlarged
view.)
“There are other evaporative humidifiers that use electricity to
heat water in a pan for evaporation (Figure 4). These units are resistance heat
units that use quite a lot of electricity for evaporation.
“Next, atomizing humidifiers - Some of these units are much like
an oil burner nozzle and spray water directly into the air stream (Figure 5).
Care must be taken that all of the moisture is absorbed into the air stream, or
the excess may gather in the duct, so some of them spray water against a pad to
ensure evaporation.
“Some humidifiers use a centrifugal rotor to sling water into a
mist, similar to a baby’s humidifier (Figure 6). These are often used in the
return air duct because the supply air duct is in a positive pressure.
“All of these humidifiers have their good points. You should look
at the effectiveness of the unit, the installation cost, the operating cost,
the maintenance cost, and initial cost before recommending a unit for a
particular installation.”

Figure 4. This humidifier uses electric resistance heat to
evaporate water into the air stream.
Bob asked, “How am I going to ever understand enough to make this
decision?”
Btu Buddy suggested, “Work with the salesman to work up the
estimate and he will show you how to compare the units. The next time you are
called on to do this, you will have a basic understanding and will be able to
select a unit just from looking at the installation.”
Btu Buddy then added, “You also need to consider how to control
the humidifier.”
Bob said, “Don’t tell me there is more to this.”
Btu Buddy said, “Not much more. Different manufacturers recommend
different methods of control. Even the outside temperature and the type of
windows the house has will enter into the control of the system. Have you ever
seen a house where the windows were sweating on the inside?”

Figure 5. This humidifier uses a spray nozzle to atomize water
into the air stream.
Bob said, “Yes, that can lead to deteriorating wood around the
windows.”
Btu Buddy agreed and said, “When a house has single pane windows,
the humidity in the house must be kept below the dew point temperature of the
inside surface of the windows or they will sweat. It is recommended that a
humidistat be installed in the house and that the homeowner be educated to look
for sweat on the windows and to turn the humidistat down at the first sign of
fog or sweat. Some manufacturers use electronics to monitor the outdoor temperature
and indoor humidity to automatically keep this from happening. That gets into a
very sophisticated system.”
Btu Buddy then said, “Most of the humidifiers must also be
interlocked with the fan, so the unit will not operate unless the fan is running
and in the heating cycle. This is particularly true with the atomizing type.
Most circuit boards on furnaces that have electronic circuit boards have a
connection for humidifiers and electronic air filters that takes care of this
for you. In the event that there is no connection, other methods can be used.
For example, you could use a sail switch that would change position when there
is airflow. The only thing that must be considered here is that if the system
has cooling, you don’t want the humidifier operating in the summer. A
temperature sensor can be installed that will only allow the unit to operate
when the air temperature is hot.”

Figure 6. This humidifier uses centrifugal force to break the
water up into fine particles and then they are sprayed into the air stream to
mix with the air.
Bob said, “There are a lot of things to consider in this
installation.”
Btu Buddy then said, “Remember the mineral buildup that occurs in
the water when water is evaporated. As water is evaporated, any minerals will
be left behind. Many humidifiers have a system that will change the water in
the humidifier sump by letting some of the water go down the drain to allow
fresh water into the sump. This will dilute the minerals in the sump. You must
provide a place to drain the water from this sump if it has a dilution system.
Get with the salesman and he will fill you in on which system will fit the job
you are working on. I will meet you at the job later today and see what you
came up with.”
Later in the day, Bob and Btu Buddy met at the job and Btu Buddy
asked, “Which system did you decide on?”
Bob said, “We decided on the bypass type system because the
system is a heat pump. The salesman was a big help showing me the differences
in the available systems. I was prepared to talk to him on his level because we
had lunch together today. I have the system in the truck along with a
humidistat and some drain line that I will pipe into the system’s condensate
drain system from the air conditioning cycle. This heat pump has an electronic
circuit board with a connection for a humidifier. The salesman showed me the
file where he had sold the system and pointed it out to me in the unit
literature.”
Btu Buddy said, “You had another day of experiences today. This
day will serve you well in the future.”
Bob said, “Again, I would like to thank you for all of your
help.”
Publication
date: 03/23/2009