ACHR News
search
Ask ACHR NEWS AI
cart
facebook twitter instagram linkedin youtube
  • Sign In
  • Subscribe
  • Sign Out
  • My Account
ACHR News
  • NEWS
    • Breaking News
    • New HVAC Products
    • Featured Products
    • Manufacturer Reports
    • HVAC Data
    • Legislation
    • ACHR NEWS Centennial
  • RESIDENTIAL
    • Air Conditioners
    • Furnaces
    • Residential Heat Pumps
    • Ductless
    • Residential IAQ
    • Testing, Monitoring, Tools
    • Components & Accessories
  • COMMERCIAL
    • Air Handlers
    • Rooftop Units
    • Chillers and Cooling Towers
    • Commercial Heat Pumps
    • Boilers and Hydronics
    • VRF/Ductless
    • Commercial IAQ
  • REFRIGERATION
    • Refrigerants
    • Refrigerant Regulations
    • Leak Management
  • CONTRACTOR PRO
    • Geothermal
    • Homeowner Study
    • VRF and VRV Ductless
    • Unitary Trends
  • EDUCATION
    • Training and Education
    • Business Management
    • Service and Maintenance
    • Continuing Education
    • Market Research >
      • HVAC Brand Awareness Report
      • VRV, VRF, VRVZ Report
      • Unitary Trends Report
      • Water Heat Professionals Report
    • Webinars
    • Sponsor Insights
    • eProducts Info
    • White Papers
  • EVENTS
    • HVAC Contractor Forum
    • Industry Events and Webinars
  • MEDIA
    • Videos
    • AHR Expo 2025 Videos
    • Podcasts >
      • ACHR News Podcast
      • HARDI Podcasts
      • AHR Expo Podcasts
      • ACCA Podcasts
    • Interactive Spotlights
    • Quizzes
    • eBooks
    • HVAC Talkback
  • HVAC GROUP
    • ACHR NEWS >
      • Current Issue
      • Digital Edition
      • Subscribe
    • Distribution Trends
    • SNIPS NEWS >
      • Join SNIPS NEWS
    • Engineered Systems News >
      • Join ES News
    • HVACR Directory
    • Contests
    • Newsletters
    • Contact
    • Advertise
    • My Account
Regional ReportsSouth

Orlando Office Building Solves A Longstanding Problem

August 30, 2002
ORLANDO, FL — The First Union Tower is a modern building in a prime location in Orlando. The only problem with the facility was that the building cooling plant couldn’t keep up with the cooling demand. As a consequence, comfort levels in the building did not meet the performance standards expected by its owner, Hannover Real Estate Holdings, or the property manager, CB Richard Ellis. In 1999 the building’s HVAC plant received a complete makeover that has resulted in improved comfort and system flexibility, with no increase in operating costs.

The building opened in early 1984 and encompasses 292,000 square feet of rental space. The 16-story facility houses approximately 40 tenants.

The original chiller plant for the building was two Trane CenTraVac™ centrifugal chillers, Model CVHA, rated at 230 tons each. The chillers provide chilled water to fan-coils on the second floor and to air handlers on floors three through 16. The first two floors have an independent cooling system.

In the original system, chilled water was piped from the chillers at the basement level to the upper floors via a PVC riser in an interior pipe chase. The condensing water from the chillers is piped on a common loop to the cooling towers, which are on ground level alongside the building. The original cooling tower was a single-cell unit rated at 440 tons.

MORE CHILLER CAPACITY NOT THE ANSWER

In 1992, because of increasing heat loads from office computer equipment and increases in building ventilation rates, an additional 195-ton Trane Series R™ water-cooled screw chiller was installed. The chiller was included on the same chilled water and tower water loops as the original system. But, it was discovered that, although the additional chiller provided redundant capacity, it did not contribute to better building cooling because it was constrained by the limited cooling tower capacity and the undersized air handlers on the upper floors.

This was the situation when CB Richard Ellis took over management of the building in April 1998. Up until that time, the strategy had been to pre-cool the building in advance of weekday occupancy, sometimes starting as early as Sunday afternoon. Even so, on the warmest days, the building was unacceptably warm by mid-afternoon. Despite the fact that there was adequate chiller capacity, there wasn’t enough cooling tower capability to shed the excess heat. Further, there wasn’t adequate capacity in the airside plant to allow air volume at desirable levels. A solution was needed.

The management firm worked with the owner to develop a plan for improving the comfort level of the building. The challenge the engineers at CB Richard Ellis faced was designing a system that could be installed without interrupting tenants’ operations. This was particularly challenging given the tight clearances in the mechanical rooms on each floor. The engineering work was done during the second half of 1998 and the project equipment was bid in January 1999. Work began in July 1999.

PIPING IMPROVEMENTS

The new design involved both the chilled water distribution system and the airside plant. A new steel pipe was scheduled to be installed to replace the PVC riser. Coincidentally there was a failure on the PVC pipe just as the project was starting. The riser was temporarily repaired until the replacement steel pipe was in place. The eight-inch chilled water mains were replaced with 10-inch lines. Piping was replaced to each air-handling unit (AHU) to reflect the increased AHU size as well.

The entire central plant system was completely repiped to achieve a true primary-secondary chilled water system. The chilled water pumps were changed from constant speed to variable speed types.

Condenser water pumps were relocated to an area near the ground level cooling towers. This saved space in the building mechanical room and reduced pumping costs.

Looking for quick answers on air conditioning, heating and refrigeration topics? Try Ask ACHR NEWS, our new smart AI search tool. Ask ACHR NEWS →

The existing single-cell cooling tower that was designed for 1,320-GPM was replaced with a new three-cell Marley cooling tower rated for 2,550-GPM. The cooling towers are designed for an operating range of 95-85 degrees F.

All of these cooling tower and chilled water plant improvements were made without taking the existing system out of service during the workweek. While parts of the cooling tower system were out of service during the building improvement process, a rental air-cooled chiller from Trane’s ChillerSource™ unit was installed. This chiller assured continuing chilled water service to the air handlers and fan-coils.

AIRSIDE CAPACITY DOUBLED

The airside part of the solution involved changing the air handlers on the upper floors to allow a supply of one CFM of conditioned air per square foot. The previous system had supplied only 0.54 CFM per square foot.

All of the air handlers on the upper floors were replaced with Trane Modular Climate Changer™ air-handling units. The clearances of the mechanical rooms on each floor were so tight that the old units had to be disassembled to be removed. The new units were also installed in pieces and assembled in place. The modular design of the Trane air handler made this possible. Work was scheduled so that one air handler was replaced each weekend until the project was done. In this way, disruption of customer operations was minimized.

Bruce H. Hall at CB Richard Ellis worked with Chris St. John in Trane Orlando to assure that the new air handlers and other equipment would fit in the tight spaces and could be disassembled if necessary. The Trane office also worked with the Trane Lexington plant where the air handlers are manufactured to stage deliveries to meet the week-by-week replacement schedule.

CONTROLS UPGRADED

In addition to the chilled water plant and airside improvements, the original building control system was replaced with a Tracer Summit™ system.

This improvement allows much closer monitoring of conditions throughout the building and increases system efficiency by optimizing chiller, pumps, and cooling tower operation. The Tracer Summit system also included a tenant services module. This software feature allows automated requests for temporary service schedule changes and simplifies the billing for special services such as night or weekend occupancy.

Trane wireless controls were installed on the VAV boxes on all of the upper floors. This simplifies relocation of sensors as areas are remodeled to suit changing future tenant needs. The management firm is able to reduce labor costs in facility remodeling. In addition, Trane UCP2™ controls were installed on the two older centrifugal chillers that will allow more complete unit diagnostics, monitoring, and optimization.

PROBLEM SOLVED

As a result of the HVAC plant improvements, the First Union Tower now provides control of the building environment, even during the hottest time of the year. With the waterside improvements, chilled water is delivered to the air handlers and fan-coils at 42 degrees F and returns at 57 degrees.

The new air handlers allow complete environmental control with specified fresh air makeup, even on the hottest days. Despite the increases in the size of much of the service equipment, building energy usage did not increase. Pre-cooling of spaces is no longer necessary and tenants can enjoy an optimum office environment.

For additional information, contact 651-407-3921 or www.trane.com.

Publication date: 09/02/2002

Share This Story

Looking for a reprint of this article?
From high-res PDFs to custom plaques, order your copy today!

 

Recommended Content

JOIN TODAY
To unlock your recommendations.

Already have an account? Sign In

  • HVAC-enrollment

    The Trades Are Back: HVACR Programs See Nearly 30% Enrollment Spike

    A new wave of future technicians is entering the pipeline.  
    News
    By: Matt Jachman
  • 2025 Top 40 Under 40

    2025 Top 40 Under 40 HVACR Professionals List

    The 11th annual Top 40 Under 40 list highlights those...
    HVAC Contracting
    By: Hannah Belloli-Oster
  • LG Ductless Mini-Split Systems

    The 9 Types of Heat Pumps

    As the U.S. moves toward electrification, heat pumps are...
    Ground Source Heat Pumps
    By: Joanna R. Turpin
Subscription Center
  • Create an Account
  • Start a Subscription
  • Manage My Account
  • Sign Up for Newsletters
  • Visit Customer Service
  • Update Preferences

More Videos

Sponsored Content

Sponsored Content is a special paid section where industry companies provide high quality, objective, non-commercial content around topics of interest to The News audience. All Sponsored Content is supplied by the advertising company and any opinions expressed in this article are those of the author and not necessarily reflect the views of The News or its parent company, BNP Media. Interested in participating in our Sponsored Content section? Contact your local rep!

close
  • Piggy Bank
    Sponsored byWatercress Financial

    Energy Prices, Inflation, and HVAC: What Today’s Homeowners Care About

  • Refrigerated Food
    Sponsored bySolstice Advanced Materials

    R-455A Refrigeration: A Cold Storage Solution for the Future

  • Airex Rooftop Units
    Sponsored byAirex Manufacturing Inc

    Consolidating Roof Penetrations: A Growing Trend in Multifamily HVAC Design

Popular Stories

HVAC-Price-Increase-graphic

HVAC Price Increase List: June 2026

Trump-Section-232.jpg

Trump Reduces Section 232 Tariffs on HVAC Equipment to 15%

R410A-Refrigerant-Cylinder.jpg

Refrigerant Recovery is a Revenue Opportunity

Heat-pump-cutaway.jpg

PFAS Rules and A2L Building Codes Continue to Evolve

Kroger.jpg

Kroger to Spend $100 Million to Reduce Refrigerant Leaks

View The ACHR NEWS
Centennial Anniversary Timeline

The ACHR News Timeline Chart
Submit a Letter
Submit a letter to our editors.

Events

November 6, 2025

Next-Gen Data Center Cooling: HVAC Innovation and Real-World Solutions

On Demand As AI workloads and high-density computing push traditional cooling methods to their limits, the data center industry is accelerating the adoption of next-generation HVAC technologies.

June 17, 2026

Decarbonization Without Disruption

This webinar will explore practical HVAC decarbonization strategies that minimize disruption while maximizing long-term performance and ROI.

View All Submit An Event

Poll

Summer Staff

Are you fully staffed for the summer season?
View Results Poll Archive

Products

BNI Mechanical/Electrical Square Foot Costbook, 2026 Edition

BNI Mechanical/Electrical Square Foot Costbook, 2026 Edition

See More Products
A2L Refrigerants - Free Webinar - May 21, 2026

Related Articles

  • Aeroseal: Sealing Small Leaks Solves a Big Problem

    See More
  • New Technique Solves IAQ Mystery In Office Building

    See More
  • back2basics

    Building Program To Basis Of Design For A New Commercial Office Building Shell & Core Building Project

    See More

Related Products

See More Products
  • Green Tips for Building Maintenance Engineers

  • Building Information Modeling: Planning and Managing Construction Projects with 4D CAD and Simulations

  • Lessons Learned in a Boiler Room: A common sense approach to servicing and installing commercial boilers

See More Products

Related Directories

  • Johnstone Supply Orlando

×

Sign Up. Stay Informed.

The #1 trusted source for the HVACR industry since 1926

SUBSCRIBE
  • RESOURCES
    • Advertise
    • Contact Us
    • Advisory Board
    • Classifieds
    • Submit a Letter
    • Directories
    • Store
  • ACCOUNT CENTER
    • Create an Account
    • Start a Subscription
    • Manage My Account
    • Sign Up for Newsletters
    • Visit Customer Service
    • Update Preferences
  • SERVICES
    • Marketing Services
    • Reprints
    • Market Research
    • List Rental
    • Survey/Respondent Access
  • STAY CONNECTED
    • LinkedIn
    • Facebook
    • Instagram
    • YouTube
    • X (Twitter)
  • PRIVACY
    • PRIVACY POLICY
    • TERMS & CONDITIONS
    • DO NOT SELL MY PERSONAL INFORMATION
    • PRIVACY REQUEST
    • ACCESSIBILITY

Copyright ©2026. All Rights Reserved BNP Media, Inc. and BNP Media II, LLC.

Design, CMS, Hosting & Web Development :: ePublishing